Recirculation Pump Control
Recirculation Operation –
On-Demand mode-
If the On-Demand mode is used, the water heater
needs wifi capability.
If the water heater is NOT a WiFi model, you cannot
use the On-Demand mode.
To enter On Demand Mode
• Ensure Switch 1 on DIP 2 and switch 4 on DIP 1
are off.
• In less than one minute.
• Turn Switch 1 on DIP 2 on-off-on-off.
• Press the Adjust Button
• The PCB LED will flash one time
The unit is now in on demand mode.
NOTE:
If the water heater does not have WiFi capability,
the built-in display needs to be replaced with the
display including WiFi capability.
Rheem offers the display including wifi capability.
See the Parts and Accessories catalog for more
information.
When set to On-Demand mode, the recirculation
pump is ON for 5 minutes when the water heater
receive the signal form the application on smart
phone.
USING YOUR WATER HEATER
Mode setting – On-Demand mode-
Please refer to EcoNet app for
Recirculation Operation – Schedule
mode-
If the Schedule mode is used, the water heater needs
wifi capability.
If the water heater is NOT a WiFi model, you cannot
use the Schedule mode.
NOTE:
If the water heater does not have WiFi capability,
the built-in display needs to be replaced with the
display including WiFi capability.
Rheem offers the display including WiFi capability.
See the Parts and Accessories catalog for more
information.
When set to Schedule mode, the recirculation
pump is ON according the setting schedule on the
application on smart phone
Mode setting – Timer mode-
To use Schedule mode, the water heater should be
set to Performance mode or Timer mode.
instructions.
61