Advertisement

Quick Links

Astra 38
Owner's Manual
Model Number: 38SFC
This product is proudly developed and manufactured in North America by SUPREME FIREPLACES INC.
3594 Jarry East, Montreal, QC H1Z 2G4
T: 877-593-4722, F: 514-593-4424
www.supremem.com
Revised: April 2020
IMPORTANT: Keep the owner's manual for future use.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 38SFC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SUPREME 38SFC

  • Page 1 Astra 38 Owner’s Manual Model Number: 38SFC This product is proudly developed and manufactured in North America by SUPREME FIREPLACES INC. 3594 Jarry East, Montreal, QC H1Z 2G4 T: 877-593-4722, F: 514-593-4424 www.supremem.com Revised: April 2020 IMPORTANT: Keep the owner’s manual for future use.
  • Page 2: Table Of Contents

    Chimney Sweeping Cap ........................4 Door ..............................4 Certification Label ..........................5 Removable Ash Lip ..........................5 SUPREME Radiation Shield Offset ..................... 5 2.10 Baffle Secondary Burn Technology ..................... 5 2.11 Cast Iron Interior ..........................6 2.12 Blower Kit ............................6 2.13 Optional Hot Air Kit ..........................
  • Page 3 3.5.1 Dual Louver Gravity Ducts ......................16 3.5.2 Single Linear Front Louver ......................18 Hearth Extension ..........................22 Chase Installation ..........................23 Clearances to Combustibles ......................24 Blower Kit ............................25 OPTIONS ..............................27 Hot Air Kit ............................27 Fresh Air Kit ............................29 OPERATION INSTRUCTIONS .........................
  • Page 4: Safety

    SAFETY SUPREME FIREPLACES INC. congratulates you on purchasing an Astra 38 wood burning fireplace. This manual describes the installation and operation of the Astra 38 non-catalytic wood heater. This heater meets the 2020 U.S. Environmental Protection Agency’s crib wood emission limits for wood heaters sold after May 15, 2015.
  • Page 5: General Information

    GENERAL INFORMATION 2.1 Overall Dimensions Figure 2-1: Astra 38 Traditional Dimensions Figure 2-2: Astra 38 Clean Face Dimensions...
  • Page 6: Specifications

    125,000 BTU (36.6 kWh) Efficiency Protocol: CSA B415.1-10 WARRANTY REGISTRATION Please register your SUPREME product online at http://www.supremem.com/warranty.php to ensure full warranty coverage. Proof of purchase is required for all warranty claims. Depending on combustion air control setting (see Section 5.3 for further details).
  • Page 7: Combustion Air Control

    2.3 Combustion Air Control The Combustion Air Control is a patented mechanism (Patent No: US 7,325,541 B2) that regulates the air flow into the firebox based on the temperature of the unit. It is located on the top of the firebox, at the front center of the unit.
  • Page 8: Certification Label

    NOTE: The door of the Astra 38 must remain closed at all times during operation. 2.9 SUPREME Radiation Shield Offset The SUPREME Radiation Shield Offset is a standard component for the Astra 38 fireplace (Figure 2-8). Prior to installing the chimney manufacturer’s radiation shield, the SUPREME Radiation Shield Offset is fastened below the chimney opening within the chase, with the flanges along the component providing a ½”...
  • Page 9: Cast Iron Interior

    (breaker off) before accessing the electrical wiring of the hot air kit. CAUTION: Only a hot air kit provided by SUPREME FIREPLACES INC. can be installed onto the fireplace. Substituting the hot air kit may result in overheating, will void the warranty and can be hazardous.
  • Page 10: Installation Instructions

    (Canada) or the ANSI NFPA 211 Standard for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances (USA). CAUTION: Modifications/alterations to the unit/installation without written authorization from SUPREME FIREPLACES INC. are strictly forbidden and will void the warranty. Refer to Section 1 for further Figure 3-1: Straight Wall Installation safety information.
  • Page 11: Chimney Installation

    3.2 Chimney Installation The Astra 38 is approved with a 6” chimney that is listed under the UL 103 / ULC S629 standards (refer to Table 3-1). WARNING: Mixing chimney components from different brands is a safety hazard and will void the warranty on the unit.
  • Page 12: Listed Ul 103 / Ulc S629 Approved Chimney Models (Reference Table)

    2. For an installation with the chimney running through the ceiling, install the SUPREME Radiation Shield Offset below the chimney opening prior to installing the radiation shield (refer to Figures 2-8 and 3-7).
  • Page 13: Offset Installation

    M2000 (Canada) or UL 1777 (US) standards must be installed within the existing masonry Connector chimney. Note that the 6CON connector (manufactured by SUPREME FIREPLACES INC.) must be installed to connect the prefabricated chimney to the liner (6CON sold separately).
  • Page 14 Note that prior to installation, an inspection from an authority having jurisdiction is required to determine whether the masonry chimney: • Is constructed in accordance with national and municipal building codes. • Is in good condition. Note that repairs must be performed on any cracked or missing bricks. •...
  • Page 15: Framing

    3.3 Framing The Astra 38 can be placed directly onto or against normal, combustible construction materials such as lumber, plywood, millboard, particleboard, drywall and decorative wood paneling. The fireplace should NOT be placed directly against or be in contact with an insulation material. A portion of the framing on the face of the chase must be constructed with nominal 2"...
  • Page 16: Surround Installation

    3.4 Surround Installation The Astra 38 can be installed with either the traditional surround or the clean face surround. 3.4.1 Traditional Surround The traditional surround comprises louvers below (intake) and above (outtake) the door. All components and fasteners are included in the surround kit. Refer to Figure 3-14 and Table 3-2 for the instructions below. 1.
  • Page 17: Clean Face Surround

    Figure 3-14: Traditional Surround Components Table 3-2: 3238ATFA-11 Components TRADITIONAL ITEM DESCRIPTION Traditional Surround Lower Support Bracket Upper Support Bracket 3.4.2 Clean face Surround The Clean Face surround comprises no louvers; however, an intake into the chase and an outtake through gravity ducts is required for this configuration.
  • Page 18 Figure 3-15: Intake Swivel Cover Kept Open for Clean Face Figure 3-16: Clean Face Surround Installation Installations Figure 3-17: Clean Face Surround Components Table 3-3: 3238ATFA-12 Components CLEAN FACE ITEM DESCRIPTION Clean Face Surround Clean Face Upper Cover Clean Face Lower Cover Duct Adapter...
  • Page 19: Gravity Kit Installation

    (Figure 3-22). Please note that the SUPREME KG540 kit and the UCAC8 semi-rigid insulated ducts are required for the Gravity Kit installation (Figure 3-21).
  • Page 20 Table 3-4: KG540 Components ITEM DESCRIPTION ILLUSTRATION 11”x 12” grille LW1021 for intakes and outtakes Duct/louver LW1000 adapter 45° elbow, 8” 4358C26 diameter 8” worm gear HAMGC-128 clamp Figure 3-21: KG540 Assembly Diagram WARNINGS: • The gravity ducts must extend upwards from the top of the unit and cannot exceed 10 feet.
  • Page 21: Single Linear Front Louver

    The instructions below describe the installation of the intake openings and the single linear front gravity ducts/outtakes. Please note that the SUPREME LV32 kit is required for the Gravity Kit installation with a single linear front louver (Figure 3-23).
  • Page 22 INSTALLATION: Install the linear duct/louver adapter (item SL1110 of Figure 3-23 and Table 3-5) onto the framing of the single linear front louver (Figure 3-24). The brackets of the SL1110 (SL1153 of Figure 3-23) are adjustable to accommodate different wall finishing materials (Figure 3-25). Temporarily install one of the 90°...
  • Page 23 Uninstall the 90° elbow from the linear duct/louver adapter. Add 3 inches to the distance L and cut the two CAC8 ducts (Figure 3-23 and Table 3-5) to that length. Insert a worm gear clamp on each end of the ducts (Figure 3-28). Install the 90°...
  • Page 24 10. Once the chase has been built, locate the linear duct/louver adapter outlet and cut an opening on the chase finishing material of 30.75” (W) X 4.5” (H) centered with the outlet (Figure 3-33). Figure 3-33: Opening for Air Outtake 11.
  • Page 25: Hearth Extension

    3.6 Hearth Extension The hearth extension of the Astra 38 must comprise of a non-combustible material, such as steel, cement or mortar, bricks, or ceramic tiles. Note that unidentified materials may be combustible; verify product specifications prior to installation. The hearth extension must extend a minimum of 18” from the front of the door, 8” from side of the outer frame of the door and extended all the way to the unit (see Figure 3-35 for dimensions and Figure 3-36).
  • Page 26: Chase Installation

    3.7 Chase Installation A portion of the front of the chase must be constructed out non-combustible material. Refer to Figure 3-37, 3-38, and 3-39 for dimensions. Note the chase must be properly fastened onto the framing structure. WARNING: Do not nail or screw the chase onto the fireplace. For the clean face surround option, two intake openings must be constructed onto the chase, as well as two outtake openings or one if installing the linear single louver front (Section 3.5).
  • Page 27: Clearances To Combustibles

    3.8 Clearances to Combustibles The clearances below must be respected to ensure safe operation of the unit under normal and extreme conditions. Failure to follow the information below is a safety hazard and may result in property damage. Table 3-6: Overall Clearances Combustible Clearance Reference...
  • Page 28: Blower Kit

    Hz, and 56 W. A variable speed control (rheostat) and a heat sensor (therm-o-disc) are included with the kit. WARNING: Only blowers provided by SUPREME FIREPLACES INC. can be installed into the fireplace. Substituting the blower kit may result in overheating, will void the warranty and can be hazardous.
  • Page 29 Figure 3-42: Access to Blowers Figure 3-43: Electrical Diagram Figure 3-45: Blower and its Fixture Figure 3-44: Access to Blowers...
  • Page 30: Options

    CAUTION: Only a hot air kit provided by SUPREME FIREPLACES INC. can be installed onto the fireplace. Substituting the hot air kit may result in overheating, will void the warranty and can be hazardous.
  • Page 31 Installation: 1. Remove the 5’’ knockout on the exterior casing of the fireplace using a flat head screwdriver (Figure 4-1). WARNING: Only remove the knockouts that will be connected to a hot air kit system. 2. Install the fireplace duct connector (FDC - #5) on the opening using four screws. 3.
  • Page 32: Fresh Air Kit

    • The air register can be installed above or below the level of the fireplace. • Use the SUPREME FIREPLACES INC. Fresh Air Adapter (ADP4) provided with the unit. • Use the SUPREME FIREPLACES INC. Fresh Air Kit (UPEA4). Installation: 1.
  • Page 33: Operation Instructions

    OPERATION INSTRUCTIONS 5.1 Fuel The Astra 38 is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods (moisture content below 20%), as compared to softwoods or to green or freshly cut hardwoods. The following are a few signs indicating that firewood is sufficiently dry for use: (a) cracks on the ends and surface of the logs, (b) lighter in weight, and (c) color (yellow/grey).
  • Page 34: Starting A High Efficiency Fire

    The left combustion control lever is the Activator. When starting a fire or adding a new load of wood, the Activator must be pushed in to allow maximum air to enter the firebox. The right combustion control lever is the Burn Rate Selector.
  • Page 35: Adding A New Load Of Wood

    NOTE: Sufficient air exchange is necessary for the fireplace to operate properly. Air is required in order to maintain the combustion of the fireplace. If the house is airtight, the fireplace may not function properly. If the fireplace is deprived of air, it will be necessary to provide a source of fresh air into the dwelling. This may be done by using an air exchanger unit or simply by opening a window or a door near the fireplace partially for a few minutes.
  • Page 36: Troubleshooting

    TROUBLESHOOTING 6.1 Backdraft / Smoking Draft is the force created by a difference in pressure, which moves air from the appliance up through the chimney. It is important to operate the Astra 38 with proper draft to ensure optimal performance of the unit. Draft is depended on the length of the chimney, local geography, nearby obstructions and other factors.
  • Page 37: Maintenance

    MAINTENANCE 7.1 Disposal of Ashes Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a non-combustible floor or on the ground, well away from all combustible materials, pending final disposal.
  • Page 38: Cleaning Of Glass

    WARNING: Do not operate the unit with any of the cast iron panels missing. 7.5 Replacing the Door Gasket SUPREME FIREPLACES INC. assembles heat resistant graphite coated gaskets on the doors of all products, allowing for a proper seal of the unit at extreme temperatures (up to 1000 F).
  • Page 39: Replacing The Glass Panel

    7.6 Replacing the Glass Panel Table 7-1: Parts List of Door Assembly Item Code Description SUPREME FIREPLACES INC. uses a high quality 5mm thick DR2100-* Door frame assembly Pyroceram III / Keralite ceramic glass that can withstand DR_25.75 Horizontal metallic bracket temperatures up to 1300 F.
  • Page 40: Door Latch Maintenance

    7.7 Door Latch Maintenance Lightly lubricate the hook of door latch (CM0031) with grease on a yearly basis to prevent abrasive wear. Occasionally inspect the bushing of the door latch. If required, adjust the tightness of the latch bolt using a 5/32” hex key.
  • Page 41: Replacement Parts

    7.9 Replacement Parts Refer to the codes from the table below for any replacement parts: Code Description Illustration SFC0032 Wood pull handle Pyroceram III / Keralite 5mm thick PYRO_24.25_17 glass 24.25" X 17" Graphite coated square gasket, GSK_19_7.5 0.1875" thick, 7.5' length Graphite coated square gasket, GSK_31_7.5 0.75"...
  • Page 42: Warranty

    EXCLUSIONS: SUPREME FIREPLACES INC. shall not be responsible for any labor costs for the replacement or repair of any electrical components, painted/plated parts, secondary air burning system, and the combustion air control. The cast iron panels are covered under the warranty for 10 years.
  • Page 43 In the case of a return for repair or replacement, it is the responsibility of the customer to adequately package the component/unit to prevent further damage during transport. Items sent to the SUPREME FIREPLACES INC. without an open warranty claim will be returned to the sender.

This manual is also suitable for:

Astra 38

Table of Contents