MPI/PPI user manual
(english)
Art.Nr. 9350
Art.Nr. 9350.05M
Art.Nr. 9350.10M
Art.Nr. 9350.15M
11.02.2021
© PI 2021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9350 and is the answer not in the manual?

Questions and answers

Summary of Contents for PI 9350

  • Page 1 MPI/PPI user manual (english) Art.Nr. 9350 Art.Nr. 9350.05M Art.Nr. 9350.10M Art.Nr. 9350.15M 11.02.2021 © PI 2021...
  • Page 2: Installation

    index of contents MPI/PPI 1 Description 2 System requirements 2.1 Operating system (s) 2.2 Software 2.3 Hardware 3 Installation 3.1 Hardware 4 Control elements 4.1 Display 5 Implementing 5.1 Programming software to use with direct access 5.1.1 PG2000 für S7 (V5.10) 5.1.2 PSet PG/PC interface 5.1.2.1 TCP/IP RFC1006 Communication 5.1.2.2 MPI setting...
  • Page 3 5.1.6 ProTool/Pro v6.0 SP2 5.1.7 Microwin v3.2 (only for S7 200) 5.1.8 S7 for Windows v5.02 6 S7-Interface Configurator Help 6.1 Language selection: 6.2 User interface: 6.3 Bus configuration 6.4 Network settings 6.5 Parameterize TELEService 6.5.1 Index "Network": 6.5.2 Index "Modem": 6.5.3 Index "Serial parameter": 6.5.4 Index "Access Protection": 6.5.5 Index "GSM/ISDN/SMS":...
  • Page 4 7.3.4.3.1 „Setup“ 7.3.4.3.2 „TS-function“ 7.3.4.3.3 „configure adapter“ 7.3.4.3.4 „Import parameter“ 7.3.4.3.5 „Export parameter“ 7.3.5 Tuning 8 Technical data 8.1 Pinning RS232 8.2 Pin assignment...
  • Page 5: System Requirements

    MPI/PPI Description The MPI/PPI-cable connects the programming device or the computer with the MPI-interface of an S7-300/400 or with the PPI-interface of an S7-200 over the serial interface (COM-Port). The cable recognizes automatically while attach on it on the PLC, which PLC-type is connected. At the first access from the PD´s on the cable it recognizes the baud rate for communication with the PLC.
  • Page 6 4) The connection of the modem to the MPI-cable must made with a special adapter plug (no Gender-Changer or so) Order information for the special adapter: Adapter for TS-function 9-pol Article-no. 9350-TS The adapter for the TS-function only works with the MPI/PPI–Cable with the order- number 9350 !
  • Page 7 Display Descriptions 115,2k or baud rate identification is active. USB connection Baud rate recognition and access way active. 115,2k or baud rate recognition is active. (cable is configured as TS – adapter) 19,2k 19,2k (cable is configured as TS – adapter) 38,4k 38,4k (cable is configured as TS –...
  • Page 8 Baud rate – configuration 1. line 2. line PPI 9,6k – (PPISER96) PPISER96 ACTIVE PPI 19,2k – (PPISER19) PPISER19 ACTIVE PPI 187,5k – (PPIMulti) ???PM? ???? PPILAN – (PPILAN) PPILAN ACTIVE PPIUSB – (PPIUSB) PPIUSB ACTIVE SONDSER SONDSER 19,2 kBaud 8N1 SONDUSB SONDUSB 38,2 kBaud 7E2...
  • Page 9 2. Choose from "View" => "S7-300/400" In the menu “Options“ click “Interfaces“.. 3. A dialog appears, in which you are able to set the “AG-Interface” (COM-port) in the section “Interfaces”. 4. Configure the baud rate in the section “Bus access“ to “19,2k“. Below change the value for PC - MPI to “187,5kBaud“.
  • Page 10 This step is required for the following software: => TIA-Portal => SIMATIC Step© 7 Manager => Windows Control Center (WinCC) (v6.0) => Windows Control Center flexible 2004 (WinCC flexible) (v5.2.0.0) => ProTool/Pro (v6.0 + SP2) => Microwin 3.2 1. Open the system configuration by using the start menu.
  • Page 11 4. Press "Select" to add the RFC1006 required elements interface configuration. 5. In the dialog "Select", choose" TCP / IP" and click on "Install". 6. After successful installation, click "Close". 7. Back to the “Set PG/PC interface“ dialog you will now find the desired entries called “PC - Adapter(Auto)“...
  • Page 12 10. Activate the "Automatic-mode" when you will be shure, that the connected PLC sends cyclic bus-parameter-protocols. When not please configure the bus by hand. 11. Save your configuration with „OK“ and close the „Set PG/PC–interface“ dialog with „OK“. 5.1.2.3 Profibus setting...
  • Page 13 12. Mark the entry „TIC ETH/USB(PROFIBUS)“ and click on „Properties“. 13. Open the properties dialog 14. Is the device-type is not identical with your used device, search for your device with "Search Device". Select the device in the result windows and click on the button "Apply".
  • Page 14 18. If you want to use ProTool/Pro RunTime you can set the "PG/PC Interface" by selecting the entry "DPSONLINE". Therefore you have to select "Access Point of Application" configure it as described above. The easiest way is to use the S7-LAN/MPI-LAN/MPI-USB- driver which supports USB and LAN products.
  • Page 15 3. The next dialog offers you several project types “Single-User Project”, “Multi-User Project” and “Client Project”. The next steps are the describing for the “Single- User Project”. 4. “OK” leads you to a new dialog. Type in the “Project Name” and the “Subfolder” of the project path. The chosen configuration is confirmed with “Create”.
  • Page 16 7. In the „Add new driver“ dialog select the driver which fits to your For a S7 PLC choose „SIMATIC S7 Protocol Suite.chn“. If you want to use an other PLC please inform yourself first, which driver fits with your PLC. It is very important that the selected driver fits with the PLC otherwise the connection cannot be established..
  • Page 17 9. Now you are able to type in the name of the connection. With a click on “Configuration“ a new dialog will appear. Now you are able to set the properties of the connection. Set up the station address of the PLC (in this example "2“).
  • Page 18 12. In this “Channel unit properties” you are able to see all “available connections”. Choose latest created connection and click again on „Properties”. Now you can see all the variables which has been created for this connection. In fact this connection is a new connection so there should not be any variable in the list.
  • Page 19 20. The tool could not detect a running connection so it marked the connection/s with a red ‘X’ (registry card "Channels/Connections“). Click on the last created, not active connection (with the red ‘X’) and some informations from connection will appear in the right part of the dialog.
  • Page 20 2. First you need to select “Create an empty project” on your first page. 3. In the "Device selection“mark the used operator panel (example: "TP 170A“) confirm with "OK“. 4. After the project has been created right-click in the project window on “Connections“of the sub menu “Communication“.
  • Page 21 6. Now you can start with your work. If you have finished work you can transfer this project to the panel by reading the next steps. 7. Choose „Transfer Settings“ from the sub menu „Transfer”. 8. In the new dialog change the „Mode“ to „MPI/DP“ and set the „Station address“ of the operator panel (e.g.
  • Page 22 1. Start ProTool/Pro by using the desktop link or program entry in the start menu. 2. Choose from the menu „File“ the sub menu „New“ or click on the right symbol. 3. The next dialog askes you which operator panel you are using. Mark the used panel (e.g.
  • Page 23 9. If you want to transfer you project to the panel you have to generate the project first. This can be done with a click on „File“ -„Compile“. 10. To transfer the project just click on „File“ „Download“ „Start Project Download“ or click on the right symbol Please wait while the project is transferred.
  • Page 24 3. Click on „Communications...” to start the next dialog. In the sector „Address” set up the „Remote” listbox with the station address of the PLC (e.g. „2”). If you skipped the point b („ PD/PC-set interface“) you can configure the PG/PC interface with a click on „Set PG/PC interface“.
  • Page 25 6. Confirm with „OK“ until you get back to the main window. The communication with the PLC ist now established. 5.1.8 S7 for Windows v5.02 1. Start the „S7 for Windows” software by using the link on your desktop or use the link in your start menu (standard is „Programs\S7 for Windows\S7 for Windows“) 2.
  • Page 26 - The number in the listbox „Max MPI Address“ must be higher than the PLC with the highest station address in your MPI bus. Otherwise every PLC which is higher than this number will not been seen (e.g. if there is only one PLC in your bus „15“...
  • Page 27: Language Selection

    Bus configuration Network settings Parameterize TELEService Index "Network" Index "Modem" Index "Serial Parameter" Index "Access Protection" Index "GSM/ISDN/SMS" Index "Internet/Mail" Tuning Factory defaults PPI Boot off Emergency-Loader Language selection: Select the menu Configuration to change the language permanently: User interface: Select near Search which interfaces are searched permanently for devices.
  • Page 28 Below the buttons is a list of the found devices. In each line an image, the type of the device, name (if existing), interface, serial number (if possible) and the OS-version of the device is displayed. On the rightmost position the actual OS-version on the harddisk is displayed. The background of the lines could use the following colours: •...
  • Page 29: Bus Configuration

    The button Update with FD updates the OS of the device and sets the factory default. The button Bootstrap sets the firmware/configuration to factory default. The button Factory defaults sets the configuration to factory default. The button Parameterize activates a dialog regarding to the device: Overview: Device Dialog...
  • Page 30: Network Settings

    Here you can parameterize the following: Use bus config for PC Tooks the bus configuration from the PC chooses the Baut rate for the cable to bus Baud rate communication The highest station-address in the bus (the less you use, the more performanceon the MPI- Highest station address bus, must be corresponding with the configuration in the...
  • Page 31 This button sets all over the network reachable devices to factory • Factory default default. • DHCP-client active When set the device acts as DHCP-client. Here you could enter the IP Address over which the device is accessed • IP address in the network.
  • Page 32 After clicking on "TELEService" a message will show up: Depending on the version of your TELEService software choose Yes or No. The regular parameters can be changed manually in the following categories: 6.5.1 Index "Network": Here you can configurate following: Station related: PD/PC is the only master on The TS-Adapter is the only master on the MPI-bus...
  • Page 33 Network type The network type MPI or PROFIBUS Transmission rate The transmission speed on the MPI bus Current transfer rate Shows the current transfer rate of the device The highest station address in the bus (the less you use, the more performance on the MPI Highest station address bus, must be corresponding with the configuration in the...
  • Page 34 There are two possible call techniques: MFV tone, the telephone number is transfered by several The phone system frequencies uses IWV pulse, the telephone number is transfered with the amount of several pulses on the line To access an outside If you need a prefix before your number to establish a call line, first dial outside, you must enter the prefix here e.g.
  • Page 35 Access Protection: The administrator can change the configuration over a telephone line. The two user accounts can not change the configuration. The username is maximal 8 characters long. Every user and the administrator should use a password which is used to login in the TELEService over a telephone-line.
  • Page 36 ISDN Modem: Choose the type of the ISDN network: AT&T 5ESS Nothern Telecom DMS-100 Type EuroISDN NET3 (Standard) INS64 US NI-1 Choose the transfer protocol type: Modem like V.120 X.75 (Standard) Protocol ML-PPP SoftBonding HDLC CLEAR Multiple Subscriber Number is used for all ISDN channels.
  • Page 37 PIN number of the SIM card, up to eight numeric characters (only for TELE-SERVICE GSM). With the button „Provider“ the provider could be choosen. Read the list of providers could be elapse more than a minute. In the end the possible provider are listed for selection. With „Automatic“ the GSM-Modem tries to connect automatically to a provider.
  • Page 38 SMS: Switches: SEND SMS RECEIVE SMS SEND+RECEIVE SMS DMTF CONFIRMATION SEND SMS+DTMF CONFIRMATION RECEIVE SMS+DTMF CONFIRMATION SEND+RECEIVE+DTMF CONFIRMATION SEND MAIL SEND MAIL+SEND SMS SEND MAIL+RECEIVE SMS SEND MAIL+SEND+RECEIVE SMS SEND MAIL+DTMF CONFIRMATION SEND MAIL+SEND SMS+DTMF CONFIRMATION SEND MAIL+RECEIVE SMS+DTMF QUITTUNG SEND MAIL+SEND+RECEIVE+DTMF CONFIRMATION Attention: before setting ON check configuration, after activating the device...
  • Page 39 local station address (should not be used twice in the Bus address TS MPI/Profibus!) from this station address the flag word and data block is accessed Bus address CPU for communication Communication communication-flagword (the first byte is the command, the flag word second is the state).
  • Page 40 The MPI/Profibus-Baudrate is not detectable Overflow in the internal MPI-Readbuffer Overflow in the internal LAN-Readbuffer Overflow in the serial Buffer The selected MPI/Profibus-Baudrate is wrong Overflow in internal LAN-Writebuffer LAN-Recieve-Error LAN-Send-Error The PD-Numberr is wrong The transferred SAP is wrong/unknown ErrCode 01: The Destination address (XXX) of a State protocol >...
  • Page 41 ErrCode 1C Data-protocol with unknown data-function-code received. (CPU=XXX,SSAP=YYh,FC=ZZh,DFC=UUh) ErrCode 1D: Received a state-protocol with error-code. (CPU=XXX,FPGA=YYh,RAM=ZZh) ErrCode 1E: FPGA has caused an interrupt although no data present. (SD1=XXh,SD1=YYh,CPU=ZZZ,FC=UUh) ErrCode 20: Unknown protocol at PPIMultimaster-Mode. (FC=XXh,Länge=YYY) ErrCode 21: Unknown baud-rate at PPIMultimaster-Mode. (Baudrate=XXh) After that additional hints are displayed.
  • Page 42 Tuning This menu is only used in some special cases. Select the device and click the button "Tuning" and after that the following dialog is displayed: The following configuration is possible, it will be transferred to the Cable by pressing the button „OK“.
  • Page 43: Factory Defaults

    send reset to cable: Send reset to cable. Console: Shows some information about the status of the connection. Factory defaults This button sets the configuration of the selected device to factory defaults. PPI Boot off In PPI boot mode S7IFC cannot communicate with the cable. To disable the PPI boot mode, click on the button PPI Boot off.
  • Page 44 • MPI-USB cable– Art. ID. 9352-USB • S7-USB module– Art. ID. 9352-S7-USB • MPI-II cable (USB – operation) – Art. ID. 9352 + 9352.1 • MPI/PPI cable– Art. ID. 9350 • Tele-Service – Art. ID. 9377-(ANALOG/ISDN/GSM)-OP • MPI/PPI-profibusmodem – Art. ID. 9379-(G)-OP 7.2 Installation...
  • Page 45 4. Wait for the installation of the files. 5. End the installation after a successful copy of data with "Finish". 7.3 Overview 7.3.1 Language After starting the application the tab Language is displayed at first: In this Dialog you could choose the used language in the application. You could choose between German and English and confirm by clicking on the desired language.
  • Page 46 In „set interface“ you can choose the COM-port you device is connected at. Only the COM-port which was aktive at starting the MPI-Kabel-Manager are shown. „Search“ update the COM-port listed in „set interface“ and put the Kabelmanager to the respective COM-port. For access query choose „Direct“...
  • Page 47 The diskette show the current operating system installed on your PC for corresponding product. The cabel-symbol on the right show the operating system which is installed on your product at the moment. With the button „default settings“ you can set your products on default settings. Should the device be out of order after configurated.
  • Page 48 7.3.4.1 Telephone book At the moment not implemented! In this dialog you could define new elements or edit/erase existing elements in your telephone- book. You could edit the following data: => Name for the connection (these are displayed at connection) =>...
  • Page 49 In this dialog, all configuration to the TS-adapter is done. The actual state of the MPI-cable is displayed right of the button “TS-function”, where the follwing 4 possible Messages could apear: „TS-Adapterfunction is NOT activ. To activate press TS-function“ The MPI-cable acts like an PC-Adapter. There will no answer for TS-spezific protocols, the attached modem will not initialized and the baud-rate to the PG/Modem is not fixed.
  • Page 50 7.3.4.3.2 „TS-function“ With this button you select the function of the MPI-cable as TS- or PC-adapter. Right of this button the actual state of the MPI-cable is displayed. 7.3.4.3.3 „configure adapter“ In the following dialog you could, after activating the MPI-cable as TS-adapter, configure the TS- spezific setup.
  • Page 51 Which local station-address is used for the TS-Adapter. Please consider that a programming device has normally the number 0, operator panel have 1, PLC’s use 2, FM/CP’s 3 etc. Please: Never use the same station-number for 2 different stations! network related: Here you can configurate following: The Nettype MPI or PROFIBUS The transfer-speed on the MPI-bus...
  • Page 52 At number of retries you could configure the number of retries for a connection before the call is stopped. When using a retry you could choose the seconds which the application should wait between calls. Serial parameter In this dialog the transfer-rate between modem and TS-Adapter is selected. The transfer-rate could choosen between the follwing values: 2400, 4800, 9600, 19.2k, 38.4k, 57.6k and 115.2kBaud The Parity could be choosen, but this is modem-dependant because some modems could not...
  • Page 53 The Access over a telephone-line on the PLC could be configured in this dialog. The Administrator could change the configuration over a telephone line, where an 2 User could not change the configuration. The User-Name is maximal 8 Chars long.Every user and the administrator could use a password which is used to log into the PLC over a telephone-line.
  • Page 54 Type: Choose the type of the ISDN-network switch: AT&T 5ESS Nothern Telecom DMS-100 EuroISDN NET3 (Standard) INS64 US NI-1 Protocol: Choose the transfer-protocol-type: Modem like V.120 X.75 (Standard) ML-PPP SoftBonding HDLC CLEAR DN/MSN: Directory Number resp. Multiple Subscriber Number Is used for both ISDN-channels. When using the number 255 no DN/MSN is used.
  • Page 55 PIN: PIN-Number of the SIM-Card, up to 8 numeric chars, (only for TELE-SERVICE GSM). Provider: With the button „Provider“ the provider could be choosen. Reading of the list of providers could be elapse more than a minute. At end the possible provider are listed for selection.
  • Page 56 in this text-field. Firstly, the modem-related information is shown: Message Modem ready Modem error No answer from modem Modem detects ring End of connection connected via modem line No dialtone detected Phone-line or telephone busy Phone-number is blacklisted in modem Phone-number delayed.
  • Page 57 ErrCode 01: The Destination address (XXX) of a State protocol > 127 detected. In the MPI/Profibus-Bus there are no stations possible which station number is greater than 127. (FC=YYh) ErrCode 02: At state-protocol the Source-Address is detected as 127. This is the Broadcast-address which is not possible.
  • Page 58 Attention: before setting ON check configuration, after activating the device will go into the MPI- BUS and tries to connect to the defined PLC. Receive of SMS only with TELESERVICE-GSM Receive of DTMF only with with TELESERVICE GSM TS: local station-address (should not be used twice in the MPI/Profibus!) PLC: from this station-address the Flagword and Data-block is accessed for communication MW: communication-flagword (the first byte is the command, the second is the state).
  • Page 59 This tab is only used in some special cases. If you press the button „Check Adapter“ the cable is connected und after that the following dialog is displayed: There are the following configuration possible, they will be transferred to the MPI-Cable by pressing the button „Transfer“.
  • Page 60: Technical Data

    never retry to connect (and then the correct version is transferred). In this case the HMI-version- information could be transferred immediately. A20-Terminal: When using the A20 or M20-Terminal, the control-lines on the serial port are not used. In that case the tele-service-function is not working. With this property the control-lines are no longer used and therefore the A20/M20 can communicate over tele-service.
  • Page 61 Direction Pin No. Notation Signalname cable) Not Connected M24V Ground of the 24V Ltg_B Data line B BiDir. RTS-AS Request to Send from the PLC Ground of the 5V 5V output P24V 24V Supply input Ltg_A Data line A BiDi RTS-PG Request to Send to the PLC Note...