OVERVIEW - READ BEFORE PROCEEDING!
1. Refer to the LEGIOMIX Quick Start Guide and instruction sheet, code H0002997, for complete instructions on setup
and commissioning.
2. Do not mount station in orientation with actuator upside down. If mounted other than shown, and not with actuator
upside down, remount the controller to normal horizontal position as it is shown here.
2. The LEGIOMIX Station components are shown below:
Purge to test/
commission
Strut frame
INSTALLATION GUIDE
Mix Out
2
1
2
Hot In
Keyed components:
1. Serviceable dual union check valves (4).
2. Isolation ball valves (5).
3. 24 V wall plug-in transformer with 20 ft cable
(not shown in this view). Strapped to strut for shipment.
4. LEGIOMIX valve/actuator.
5. Connect recirculation pump (not included, source separately) to this line.
5
Extra DIN rail for
accessories
3
2
1
4
1
1
2
2
To Tank
Cold In
1
NA10679.02
www.caleffi.com
6000AS series
Recirc
Return
Purge to
prime the
recirculation
pump

Advertisement

loading

Summary of Contents for CALEFFI LEGIOMIX 6000AS Series

  • Page 1 NA10679.02 www.caleffi.com LEGIOMIX ® Station electronic mixing system © Copyright 2021 Caleffi 6000AS series INSTALLATION GUIDE OVERVIEW - READ BEFORE PROCEEDING! 1. Refer to the LEGIOMIX Quick Start Guide and instruction sheet, code H0002997, for complete instructions on setup and commissioning.
  • Page 2 Technical specifications Mixing valve actuator current draw: 1 A max / 24 V Mixing valve body Alarm relay (R2): 5 A resistance (2 A inductance) / 24 V Contact rating (R1, R3, R4): 10 A resistance (2 A inductance) / 24 V Materials: - Body: DZR low-lead brass...
  • Page 3 LEGIOMIX Station sizing and selection procedure 1 Max. GPM (@ 5 fps pipe Station Code Station Size velocity) Station Cv 600066AS 1" 600076AS 1¼" 600086AS 1½" 600096AS 2" 600060AS 2½" Pressure drop across station (PSID) 2 Flow rates (GPM) @ above pressure drop Station size 1"...
  • Page 4 CALEFFI NORTH AMERICA THIS DRAWING, THE DESIGN AND THE PATENTS IT COVERS, ARE THE PROPERTY OF CALEFFI INC. THEY ARE LOANED MERELY AND ON THE BORROWER'S EXPRESS AGREEMENT 3883 West Milwaukee Road THAT THEY WILL NOT BE REPRODUCED, COPIED, LOANED, EXHIBITED, NOR USED EXCEPT...

This manual is also suitable for:

Legiomix 600066asLegiomix 600076asLegiomix 600086asLegiomix 600096asLegiomix 600060as