Download Print this page

Advertisement

Quick Links

Disassembly and Reassembly
Repairs must be carreid out by trained professional.
For any repairs, please contact our service provider or independent qualified professional.
AE***BXYD*G
No
Parts
1
CABI SIDE RH
2
Procedure
You must turn off the power before
disassembling.
1) Unscrew and remove 3 screws on the CABI
SIDE RH.
(Use '+' type screw driver)
2) Hold CABI SIDE RH handle and push to
downside. Pull the left side of Cabinet and
remove it.
Remark
hook
hook

Advertisement

loading

Summary of Contents for Samsung AE BXYD Series

  • Page 1 Disassembly and Reassembly Repairs must be carreid out by trained professional. For any repairs, please contact our service provider or independent qualified professional. AE***BXYD*G Parts Procedure Remark CABI SIDE RH You must turn off the power before disassembling. 1) Unscrew and remove 3 screws on the CABI SIDE RH.
  • Page 2: Cover Front

    Parts Procedure Remark COVER FRONT 1) Unscrew and remove 3 screws on the COVER FRONT. (Use '+' type screw driver) 2) Hold Top and Bottom of the COVER FRONT and push it to right side.
  • Page 3 Disassembly and Reassembly Parts Procedure Remark CABI FRONT RH 1) Unscrew and remove 3 screws on the CABI FRONT RH. (Use '+' type screw driver) 2) Hold the handle and pull the right-bottom side of cabinet. 3) Remove the CABI FRONT RH to downside. hook hook GUARD FAN...
  • Page 4 Parts Procedure Remark CABI TOP *You can remove the CABI TOP before disassembling GUARD FAN. 1) Unscrew and remove 9 screws on the CABI TOP. (Use '+' type screw driver)
  • Page 5 Disassembly and Reassembly Parts Procedure Remark CABI BACK RH *You can remove the CABI BACK RH before disassembling CABI TOP. 1) Unscrew and remove 1 screw. Remove the temperature sensor. 2) Unscrew and remove 10 screws on the CABI BACK RH. (Use '+' type screw driver) (If water pipe is connected, you don't have to remove yellow points)
  • Page 6 Parts Procedure Remark CABI FRONT LF 1) Unscrew and remove 7 screws on the CABI FRONT LF. (Use '+' type screw driver) 1) Turn the one nut as shown in the picture and remove it. (Use right size of the wrench) 2) Remove the nut.
  • Page 7 Disassembly and Reassembly Parts Procedure Remark MOTOR 1) Disconnect the motor wire from the Inverter PBA. 2) Loosen the 3 Holder wire points which are fixing the motor wire (yellow points). 3) Unscrew and remove 4 motor screws. BRACKET MOTOR 1) Unscrew and remove 2 screws on the BRACKET MOTOR.
  • Page 8 Parts Procedure Remark HEATER 1) Unscrew and remove 4 screws on the HEATER. (Use '+' type screw driver) 2) Unscrew and remove 1 screw on the COND & BASE 3) Unscrew and remove 2 screws on the BRACKET MOTOR TOP and remove it from the Cond.
  • Page 9: Control Out

    Disassembly and Reassembly Parts Procedure Remark CONTROL OUT [INVERTER PBA] 1) Disconnect 2connectors from the Inverter PBA EMI PBA 2-1) If model code is AE***BXYDEG, Unscrew and INV PBA remove 6 screws with Heatsink. 2-2) If model code is AE***BXYDGG, Unscrew and remove 2 screws with Heatsink.
  • Page 10 Parts Procedure Remark COMPRESSOR 1) Remove the all COMP FELT - Comp felt top - Comp felt out - Comp felt 2) Remove the COMP CASE. 3) Unscrew and remove 4 nuts. 4) Seperate the pipes from the Comp (3 yellow points)
  • Page 11 Disassembly and Reassembly Parts Procedure Remark ASSY PHE 1) Seperate the pipes from the PHE (Yellow points) 2) Unscrew and remove 5 points. 3) Remove the Assy PHE with Brackets.
  • Page 12 Parts Procedure Remark ASSY TUBE 4WAY 1) Seperate the pipes from the ASSY 4WAY (5 Yellow points)
  • Page 13 Disassembly and Reassembly Parts Procedure Remark ASSY TUBE SUCTION 1) Seperate the pipes from the ASSY TUBE SUCTION (6 Yellow points)
  • Page 14 Parts Procedure Remark ASSY TUBE 1) Seperate the pipes from the ASSY TUBE SUBCOOLER SUBCOOLER (6 Yellow points)
  • Page 15 Disassembly and Reassembly Parts Procedure Remark ASSY TUBE 1) Seperate the pipes from the PHE. CONNECTOR-ACCUM (2 Yellow points) 2) Unscrew and remove 4 points.
  • Page 16 Parts Procedure Remark ASSY COND OUT 1) Seperate the pipes from the COND. (Yellow points) 2) Unscrew and remove 2 points.