Owner's Manual Residential Factory Built Fireplace Operation • Maintenance • Installation DELTA2 Keep these instructions for future use. RSF-IID2_2007-01...
Page 2
We have designed your new DELTA2 to be easy to install, operate and maintain. It is in your best interest to become familiar with it. Study your manual to be sure that the installation is correct, then follow the guidelines for operation and maintenance.
9. DO NOT use a fireplace grate or other products not specified for use with this fireplace. 10. DO read the section about MOVING THE DELTA2 before you begin the installation. NOTE: We strongly recommend that our products be installed and serviced by professionals who are certified by the National Fireplace Institute in the U.S.
If you do install electricity or a thermal switch in a Clean Face DELTA2, you may have to break through the masonry finish at some point in time for maintenance purposes.
Non-combustible hearth extension and spark 3" 29 3/4" guard (refer to Table 1 (I) Refer to Table 1 and text for particulars) (G) for minimum depth of hearth extension Figure 1 Unit Dimensions and Clearances DELTA2 Owner's Manual RSF Woodburning Fireplaces...
Maximum chimney height: maximum total chimney height from fireplace top to (12,19 m) below the chimney rain cap Maximum chimney height supported by the DELTA2 fireplace (4,88 m) Minimum depth of non-combustible hearth extension: from the front of the 16"...
PAINT You can touch up the face of the DELTA2 with Stove Bright Metallic Black high temperature paint which is available at most fireplaces dealers. Follow the directions outlined on the spray can. DO NOT attempt to paint the fireplace while it is still warm.
Repeat this procedure along all sides of the door. The most important factor for controlling the burning rate of the DELTA2 is a good seal on the door gasket. If the door gasket is worn or damaged to the point where the seal is not adequate as described above, then remove and replace the gasket.
1. Take the nailing brackets provided with the unit. 2. Remove the four (4) metal screws on each side of the DELTA2 facing. 3. Attach the nailing bracket to the side of the DELTA2 using the metal screws that you removed in Step 2 (see Figure 6).
Page 10
The framing dimensions are larger than required for ease of installation. Examples shown here are for a Louvered DELTA2. An extra 12" is required either on the left or behind the fireplace of a Clean Face DELTA2 to connect the intake air duct.
Page 11
Storm Collar in the Attic Radiation Shield Ceiling Hearth Extension and Beneath Hearth Extension (refer to text for particulars) Electrical Knock-outs Outside Air inlet (refer to text for particulars) Figure 8 Louvered DELTA2 General Installation DELTA2 Owner's Manual RSF Woodburning Fireplaces...
Page 12
Intake Grill part of Clean Facing Option FO-F Hearth Extension and Beneath Hearth Extension (refer to text for particulars) Electrical Knock-outs Outside Air inlet (refer to text for particulars) Figure 9 Clean Face DELTA2 General Installation DELTA2 Owner's Manual RSF Woodburning Fireplaces...
This fireplace is certified for use with 8" ICC Model EXCEL chimney only. Please refer to Table 1 (D-E) for the minimum and maximum chimney height permitted with the DELTA2 fireplace. We recommend that the minimum height be increased by approximately 1' for every 2000' elevation above sea level.
Seal it around the chimney with silicone Clearance (see sealer (DO NOT use roofing tar). Table 1 (C)) 6. Fit the rain cap on the chimney. Secure it tightly in place. Figure 11 General Chimney Installation DELTA2 Owner's Manual RSF Woodburning Fireplaces...
We also recommend to insulate the ceiling of the chase just as if it were in the attic space. This will prevent cold air from dropping down through the chase and into the DELTA2 Owner's Manual RSF Woodburning Fireplaces...
Shield, recommended (may be with Storm required by local authorities) Installing your DELTA2 fireplace with a masonry Collar in chimney still requires using EXCEL chimney from the the Attic top of the fireplace to the wall where it will connect to a listed liner that will run up inside the masonry chimney (see Figure 15).
Page 17
You may also completely cover the top of a Louvered Always respect the DELTA2 as long as you maintain all fireplace standoff fireplace standoffs clearances and the 2" clearances around the chased chimney.
MANDATORY OPTIONS WITH THE CLEAN FACE When installing a Clean Face (FO-F) on your DELTA2, you MUST install the intake duct (part of FO-F) to provide sufficient air to the unit along with two Gravity Vent Kits (FO-V, sold separately) to provide an evacuation path for the heat.
Page 19
4. The last three refractories should be placed in front from 11.6.D left to right looking at the fireplace (left 11.8.D, middle 11.9.D and right 11.7.D). 11.8.D 11.3.D 11.9.D 11.7.D 11.5.D Figure 18 Refractory Bricks Installation DELTA2 Owner's Manual RSF Woodburning Fireplaces...
CONFIGURED OPTIONS LIST Clean Face DELTA2 Required Optional Not available Clean Face Option FO-F Gravity Vent Kit FO-V (2) Delta - Rock Retainer Kit for Clean Face FO-KD2 Inline Fan FO-CIF Central Heat Tee Option FO-T Firescreen FO-FSD2 Thermostat kit (must be installed before facing...
30 years, subject to the following conditions: During the first year RSF Woodburning Fireplaces will repair or replace, at our option, any parts which upon examination by an authorized RSF Woodburning Fireplaces representative, are found to be defective, except the parts listed in the EXCLUSIONS portion of this warranty.