CONNECTION OF THE HOB FOR 1774 - 1778
Mains
Connection
230V~ 50/60Hz
1 Phase + N
400V~ 50/60Hz
2 Phases + N
400V~ 50/60Hz
3 Phases + N
230V~ 50/60Hz
230V~ 50/60Hz
* calculated with the simultaneous factor following the standard EN 60 335-2-6/1990
Caution! Be careful that the cables are correctly engaged and tightened.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
Supply cord
3 x 4 mm²
4 x 2.5 mm²
5 x 1.5 mm²
2 Phases
3 x 4 mm
3 Phases
4 x 2,5 mm
equipped with a faulty earth connection.
68
Supply cord
Circuit braker
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
H 05 VV - F
2
H 05 RR - F
H 05 VV - F
2
H 05 RR - F
40 A *
25 A *
16 A *
40 A *
25 A *