ABB RELION 670 Series Product Manual page 139

Transformer protection
Hide thumbs Also See for RELION 670 Series:
Table of Contents

Advertisement

Transformer protection RET670 2.1 IEC
Binary input/output module, mA and time synchronization
boards.
Make BIM with 50 mA inrush current the primary choice. BIM with 50 mA inrush current fulfill additional standards. As a consequence the EMC withstand
capability is further increased.
BIM with 30 mA inrush current is still available.
For pulse counting, for example kWh metering, the BIM with enhanced pulse counting capabilities must be used.
Note: 1BIM and 1 BOM included.
Slot position (rear view)
1/2 Case with 1 TRM
3/4 Case with 2 TRM
1/1 Case with 2 TRM
No board in slot
Binary output module 24 output relays (BOM)
BIM 16 inputs, RL24-30 VDC, 50 mA
BIM 16 inputs, RL48-60 VDC, 50 mA
BIM 16 inputs, RL110-125 VDC, 50 mA
BIM 16 inputs, RL220-250 VDC, 50 mA
BIM 16 inputs, 220-250 VDC, 120mA
BIMp 16 inputs, RL24-30 VDC, 30 mA, for pulse counting
BIMp 16 inputs, RL48-60 VDC, 30 mA, for pulse counting
BIMp 16 inputs, RL110-125 VDC, 30 mA, for pulse counting
BIM 16 inputs, RL220-250 VDC, 30 mA, for pulse counting
IOM 8 inputs, 10+2 output, RL24-30 VDC, 50 mA
IOM 8 inputs, 10+2 output, RL48-60 VDC, 50 mA
IOM 8 inputs, 10+2 output, RL110-125 VDC, 50 mA
IOM 8 inputs, 10+2 output, RL220-250 VDC, 50 mA
IOM 8 inputs 10+2 output relays, 220-250 VDC, 110mA
IOM with MOV 8 inputs, 10-2 output, 24-30 VDC, 30 mA
IOM with MOV 8 inputs, 10-2 output, 48-60 VDC, 30 mA
IOM with MOV 8 inputs, 10-2 output, 110-125 VDC, 30 mA
IOM with MOV 8 inputs, 10-2 output, 220-250 VDC, 30 mA
mA input module MIM 6 channels
SOM Static output module, 12 outputs, 48-60 VDC
SOM static outputs module, 12 outputs, 110-250 VDC
ABB
X
B1
C1
D1
E1
E2
Selection for position #11.
#11
X
X
X
X
X
X
X
A
A
A
A
A
A
A
B1
B1
B1
B1
B1
B1
C1
C1
C1
C1
C1
C1
D1
D1
D1
D1
D1
D1
E1
E1
E1
E1
E1
E1
E2
E2
E2
E2
E2
E2
F
F
F
F
F
F
G
G
G
G
G
G
H
H
H
H
H
H
K
K
K
K
K
K
L1
L1
L1
L1
L1
L1
M
M
M
M
M
M
1
1
1
1
1
1
N1
N1
N1
N1
N1
N1
P1
P1
P1
P1
P1
P1
P2
P2
P2
P2
P2
P2
U
U
U
U
U
U
V
V
V
V
V
V
W
W
W
W
W
W
Y
Y
Y
Y
Y
Y
R
R
R
R
R
R
T1
T1
T1
T1
T1
T1
T2
T2
T2
T2
T2
T2
1MRK 504 155-BEN F
Notes and Rules
Note: Max 3 positions in 1/2
rack, 5 in 3/4 rack with 2 TRM
and 11 in 1/1 rack with 2 TRM
Note: Only for A10/A25/A30
X
X
X
A
A
A
Note: Maximum 4 (BOM+SOM
+MIM) boards. Only 1 BOM in
A10
B1
B1
B1
Note: Only 1 BIM in A10
C1
C1
C1
D1
D1
D1
E1
E1
E1
E2
E2
E2
F
F
F
G
G
G
H
H
H
K
K
K
L1
L1
L1
M
M
M
1
1
1
N1
N1
N1
P1
P1
P1
P2
P2
P2
U
U
U
V
V
V
W
W
W
Y
Y
Y
R
R
R
Note: Maximum 1 MIM board in
1/2 case
T1
T1
T1
Rule: SOM must not be placed
in the following positions: 1/2
T2
T2
T2
case 1 TRM slot X51, 3/4 case 2
TRM slot X71, 1/1 case 2 TRM
slot X131
139

Advertisement

Table of Contents
loading

This manual is also suitable for:

Relion ret670

Table of Contents