INSTALLATION MANUAL
LS PLUS 100 AC PROTECTOR
SIZE
CAGE
DRAWING NUMBER
A
30992
SCALE
PRODUCT CATEGORY
1:8
ECN
DATE
DD2922
3/7/2011
10701 Airport Drive, Hayden, ID 83835, USA
.
+1.208.772.8515 FAX +1.208.762.6117
.
800.882.9110 www.protectiongroup.com
B39-38-0001
PAGE
ACL
1
APPROVED
MPD
REV
A
OF
12

Advertisement

loading

Summary of Contents for Infinite LS Plus 100

  • Page 1 FRACTIONS=± .XX=± 4/6/11 TITLE INSTALLATION MANUAL ANGLES=± ° .XXX=± PROJ APPD MATERIAL 4/6/11 LS PLUS 100 AC PROTECTOR NOTED PROJECT NO. DD2922 SIZE CAGE DRAWING NUMBER THIRD-ANGLE PROJECTION NOTICE: THE INFORMATION AND 30992 B39-38-0001 DESIGN IN THIS DOCUMENT IS THE PROPERTY OF LEA INTERNATIONAL.
  • Page 3 Pre-Install Notes READ ALL WARNINGS BEFORE ANY SERVICE OR TESTING Do not install, make any adjustments, or replace any components inside the enclosure with the power supply turned on. Under certain circumstances, dangerous potentials may exist even when the power supply is off. To avoid casualties, always turn the main power supply off before performing maintenance and/or testing.
  • Page 4: Installation Procedure

    Installation Procedure Notes Please read the entire installation manual before installing this SPD. Carefully unpack the SPD, removing all packaging material. Inspect for any signs of damage that may have occurred during shipment. If any damage is found, stop installation and contact LEA International.
  • Page 5: Ac Power Connection

    AC Power Connection The SPD is installed in parallel with the incoming phase conductors. It is recommended to connect the SPD to a 60A circuit breaker. This allows for servicing of the SPD without shutting power off at the panel main breaker. Route all SPD conductors taking care to avoiding sharp bends and keeping all leads as short as possible.
  • Page 6: Troubleshooting

    Troubleshooting The SPD operational status can be seen on the front door of the enclosure. There is no need to open the unit for any reason. TVSS Status LED A green LED indicates power is applied and all SPD protection modes are normal. A red LED indicates the SPD needs servicing.
  • Page 7 Please Note: LS Plus 100 shown without the Disconnect Switch. The Operation of the Surge Counter and Audible Alarm Switch is same for both models. Alarm Disabled A Red Illuminated Light Indicates Audible Alarm is Disabled Surge Counter Records any...
  • Page 8 14-3/4" Use 1/4" [ 6 mm ] Mounting Hardware Mechanical Specifications for LS Plus 100 [ Dimensions are for Reference Only ] Mounting: External mounting brackets with 0.31" [ 7.9 mm ] mounting holes. Dimensions: 14" X 12" X 6" [ 356 mm X 305 mm X 152 mm ]...
  • Page 9 4X Wire Strip Lengths for Phase & Neutral Connections 0.5" [ 13 mm ] 4X Torque Specification 50 in-lbs [ 5.6 Nm ] Wire Range #8 to #1/0 AWG Lug Torque Specification 50 in-lbs [ 5.6 Nm ] Wire Range #8 to #1/0 AWG Wire Strip Length 0.5"...
  • Page 10 548 mm 21-9/16" 368 mm 14-1/2" Mechanical Specifications for LS Plus 100 with Disconnect Switch [ Dimensions are for Reference Only ] Mounting: External mounting brackets with 0.41" [ 10.3 mm ] mounting holes. Dimensions: 20" X 16" X 6" [ 508 mm X 406 mm X 152 mm ]...
  • Page 11: Torque Specification

    Note: Remote Alarm Remote Alarm Remote Alarm Contacts Contacts Contacts NC Contact Closed with NO Contact Open Change State with Loss Wire Range of Power SPD powered with Power OFF #24 to #14 AWG and Functional or SPD Requires [ Normal State ] Replacement Remote Alarm Contacts Normally Open...
  • Page 12 Lock Out of Enclosure in the OFF Position if Required Pull Out Locking Tab to Install Locking Device Install Lock Step 1 Turn Handle to the OFF Disconnect Handle must Position be in the OFF Position to Open or Close the Enclosure Door 3/16"-5/16"...