Advertisement
1 x Air Purifier
1 x True HEPA Combination Filter (Pre-Installed)
1 x User Manual
Power Supply | AC 120V, 60Hz |
Rated Power | 47W |
Effective Range | ≤ 442 ft² / 41 m² |
Operating Conditions | Temperature: 14°–104°F / -10°–40°C |
Humidity: ≤ 85% RH | |
Noise Level | 25–54dB |
CADR (Clean Air Delivery Rate) | 466 m³/h / 274 CFM |
Standby Power | < 0.8W |
Dimensions | 12.5 x 12.5 x 23.6 in / 31.8 x 31.8 x 60 cm |
Weight | 21 lb / 9.5 kg |
![]() | On/Off Button Turns the air purifier on/off. |
![]() | Fan Speed Button Cycles through fan speeds: low, medium, and high. |
![]() | Auto Mode Button Turns Auto Mode on/off. |
![]() | Sleep Mode Button Turns Sleep Mode on/off. |
![]() | Display Off Button
|
![]() | Check Filter Indicator Lights up red to remind you to check the filter. |
![]() | Timer Button Sets the timer. |
Fan Speed Chart
Fan Speed Indicator | Fan Speed |
![]() | Low |
![]() | Medium |
![]() | High |
Note:
Auto Mode adjusts the fan speed automatically based on air quality. For example, if the air quality is bad, the fan will be set to high speed.
Air Quality Indicator Chart | ||
Indicator Color | Air Quality | Fan Speed |
Blue | Very Good Sleep Mode | |
Green | Good | Low |
Orange | Moderate | Medium |
Red | Bad | High |
This indicator uses an automatic sensor to display the air quality. This sensor uses an infrared light to detect airborne particles The air purifier will take 30 seconds to detect the air quality each time it is turned on. During this time, the air quality indicator color will be blue. After 30 seconds, the air quality indicator color will change based on the detected air quality.
Sleep Mode uses the lowest possible fan speed to operate quietly.
You can set a timer between 1–12 hours.
Note:
The air purifier will remember its programmed settings while turned off and resume those settings when turned back on. The air purifier must remain plugged in for the memory function to work.
Note: The air purifier will not remember timers.
The True HEPA Combination Filter uses a 3-stage filtration system to purify air.
If the air quality sensor is blocked by accumulated dust, the air quality indicator may not work correctly.
will light up as a reminder to check the filter. The indicator is automatic. You may not need to change your filter yet, but you should check it when
lights up.
Reset the Check Filter Indicator when:
If not using the air purifier for an extended period of time, wrap the filter in plastic packaging and store in a dry place to avoid moisture damage.
The filter should be replaced every 6–8 months. You may need to replace your filter earlier or later depending on how often you use your air purifier. Using your air purifier in an environment with relatively high pollution may mean you will need to change the filter more often, even if is off.
You may need to replace your filter if you notice:
Note: To maintain the performance of your air purifier, only use official Levoit filters. To buy replacement filters, visit Levoit's online store. Go to levoit.com for more information.
Problem | Possible Solution |
Air purifier will not turn on or respond to button controls. | Plug in the air purifier. |
Check to see if the power cord is damaged. If it is, stop using the air purifier and contact Customer Support. | |
Plug the air purifier into a different outlet. | |
Air purifier may be malfunctioning. Contact Customer Support. | |
Air purifier makes an unusual noise when the fan is on. | Make sure the filter is properly in place with plastic packaging removed. |
Replace the filter. | |
Air purifier may be damaged, or a foreign object may be inside. Stop using the air purifier and contact Customer Support. Do not try to repair the air purifier. | |
Airflow is significantly reduced. | Make sure the filter's plastic packaging is removed. |
Tap ![]() | |
Leave at least 15 in / 38 cm of clearance on all sides of the air purifier. | |
Replace the filter. | |
Poor air purification quality. | Tap ![]() |
Make sure no objects are blocking the top or sides of the air purifier for proper airflow. | |
Close doors and windows while running the air purifier. | |
Make sure the filter is removed from its plastic packaging and properly in place. | |
Make sure the room is smaller than ≤ 442 ft² / 41 m². The air purifier may not be as effective in larger rooms. | |
Replace the filter. | |
The air purifier is producing an unpleasant odor. | Replace the filter. |
Make sure that the air purifier is in a room where the relative humidity is less than 85% RH. Higher humidity levels may cause mildew to grow on the filter. | |
![]() | Reset ![]() |
![]() | ![]() ![]() |
![]() | ![]() ![]() |
If your problem is not listed, please contact Customer Support.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Levoit LV-H133 - Tower True HEPA Air Purifier Manual
Advertisement
Need help?
Do you have a question about the LV-H133 and is the answer not in the manual?
Questions and answers