Removal Of The Three Way Diverter Valve; Removal Of The Diverter Group - Biasi ActivA Plus Service Manual

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Table of Contents

Advertisement

D
E
Figure 8.4

8.4 Removal of the three way diverter valve

1 Remove the front and both side case panels.
2 Empty the primary circuit and the d.h.w circuit of the boiler.
3 Remove the electric actuator (see "Removal of the electric
actuator" page 19).
4 5HPRYH WKH ¿[LQJ VSULQJ ) )LJXUH 
5 Remove the three way diverter valve G by levering with a
screwdriver in as shown in Figure 8.5.
G
F
H
Figure 8.5
Reassemble the three way diverter valve carrying out the remov-
al operations in the reverse order.
Warning: to lubricate the O-ring gaskets exclusively
use a silicone base grease compatible to be in con-
tact with foods and approved by the local water Au-
thorities.
Attention. When reassembling the three way diverter valve
be sure that the three way diverter is correctly oriented by
matching the reference H with the notch of the water group
Figure 8.5.
- 20 -
THREE WAY DIVERTER VALVE
C

8.5 Removal of the diverter group

1 Remove the front and both side case panels.
2 Empty the primary circuit and the d.h.w circuit of the boiler.
3 Remove the electric actuator (section "Removal of the elec-
tric actuator" page 19).
4 5HPRYH WKH ¿[LQJ VSULQJ , )LJXUH  DQG UHPRYH WKH SUL-
PDU\ FLUFXLW ÀRZ VZLWFK -
J
I
Figure 8.6
5 Disconnect d.h.w. temperature probe K.
L
Figure 8.7
6 8QVFUHZ WKH FRQQHFWRU / )LJXUH   WKH FK ÀRZ FRQQHFWRU
and the d.h.w. outlet connector.
7 Remove the d.h.w. heat exchanger (see "Removal" page
16).
8 Unscrew the screw M and remove the diverter group.
9 Reassemble the diverter group carrying out the removal op-
erations in the reverse order.
Warning: to lubricate the O-ring gaskets exclusively
use a silicone base grease compatible to be in con-
tact with foods and approved by the local water Au-
thorities.
K
M

Advertisement

Table of Contents
loading