Possible Causes Of Failure - EINHELL BT-AC 190/6 OF Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13

10. Possible causes of failure

Problem
The compressor
1. No supply voltage
does not start
2. Insuffi cient supply voltage
3. Outside temperature is too low
4. Motor is overheated
The compressor
1. Leak in the non-return valve
starts but there is no
2. The seals are damaged.
pressure
3. The drainage screw for
condensation water (11) leaks.
The compressor
1. Loose hose connections
starts, pressure is
shown on the pres-
2. Leak in a quick-lock coupling
sure gauge, but the
3. Insuffi cient pressure set on the
tools do not start.
pressure regulator.
Anl_BT_AC_190_6_OF_SPK7.indb 17
Anl_BT_AC_190_6_OF_SPK7.indb 17
GB
Cause
1. Check the supply voltage, the pow-
er plug and the socket-outlet.
2. Make sure that the extension cable
is not too long. Use an extension
cable with large enough wires.
3. Never operate with an outside tem-
perature of below +5°C.
4. Allow the motor to cool down If
necessary, remedy the cause of the
overheating.
1. Replace the non-return valve
2. Check the seals and have any da-
maged seals replaced by a service
center
3. Tighten the screw by hand. Check
the seal on the screw and replace if
necessary.
1. Check the compressed air hose
and tools and replace if necessary.
2. Check the quick-lock coupling and
replace if necessary.
3. Open the pressure regulator further.
- 17 -