Advertisement

Quick Links

Premium
Installation, Operation & Maintenance Manual
Reverse Osmosis
(RO) System
AW-PRM-75-38-Q-A ; AW-PRM-75-38-Q-C
All systems are equipped with Purefer
®
series filters

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AquaWave Premium and is the answer not in the manual?

Questions and answers

Summary of Contents for globalwater AquaWave Premium

  • Page 1 Premium Installation, Operation & Maintenance Manual Reverse Osmosis (RO) System AW-PRM-75-38-Q-A ; AW-PRM-75-38-Q-C ® All systems are equipped with Purefer series filters...
  • Page 2: Introduction And Warnings

    Congratulations on your purchase of the AquaWave™ Premium Reverse Osmosis System. The AquaWave Premium Reverse Osmosis System is designed with advanced filtration technology and utilizes a 5-stage filtration process to purify and deliver fresh-tasting water. This system is designed exclusively for municipal water systems and will remove volatile organic chemicals, chlorine, odor, sediment, suspended impurities, metals, and other harmful contaminants from your water.
  • Page 3: Specifications

    5 Stage Reverse Osmosis System OTHER IMPORTANT INFORMATION • Please note that the lifetime of the filters, as well as their replacement interval strongly depends on the inlet water quality, the amount of water consumed, the sediment and chlorine content, etc. System should be isolated from water supply and disconnected from power if not used for more than 1 week.
  • Page 4: Installation & Diagram

    INSTALLATION & DIAGRAM ™ AquaWave Premium Reverse Osmosis System COMPONENTS • #9 Water leak detector • #10 Water leak detector replacement pellet • #1 1st stage filter - K14-PP-WW • #11 Pressure regulator set to 70psi/5bar • #2 2nd stage filter - K14-GT-WW •...
  • Page 5: Installation Instructions

    5 Stage Reverse Osmosis System INSTALLATION INSTRUCTIONS If inlet water pressure is 60 psi / 4 bar, a pressure regulator Install waste water clip must be installed and set at 60 psi / 4 bar. You must check and comply with all local plumbing codes. Fig.
  • Page 6 INSTALLATION MANUAL ™ AquaWave Premium Reverse Osmosis System INSTALLATION INSTRUCTIONS Prepare RO system for installation Install RO faucet Fig. 3 Fig. 4 faucet base • Locate the position to place the RO system • Remove the faucet base from the package and ensure it can mount flat against the surface before drilling an 7/8”...
  • Page 7 5 Stage Reverse Osmosis System INSTALLATION INSTRUCTIONS • Connect this 1/4” white tube to compression filter Prepare RO system for installation - continued components as shown in Fig. 6.1 (a) Fig. 5 • Insert compression filter assembly into base of threaded stem of faucet as shown in Fig.
  • Page 8 INSTALLATION MANUAL ™ AquaWave Premium Reverse Osmosis System INSTALLATION INSTRUCTIONS Prepare RO system for installation - continued System start-up Fig. 5.2 • Ensure RO faucet is turned off/closed. • Turn on main cold water supply valve and ensure that the 1/4” water supply valve to the RO system is in open position.
  • Page 9 5 Stage Reverse Osmosis System THE RO SYSTEM FULL CONFIGURATION...
  • Page 10: Technical Data And Components

    TECHNICAL DATA AND COMPONENTS ™ AquaWave Premium Reverse Osmosis System BEFORE CHANGING THE FILTERS OF YOUR RO SYSTEM • Unplug the electricity plug of the pump and make sure no electricity is flowing into the system. • Turn off the 1/4" water supply valve. •...
  • Page 11 5 Stage Reverse Osmosis System FILTER CHANGE INTERVAL The suggested filter change interval is a non-binding recommendation based on years of experience. It represents the use of the RO system with an average inlet water quality and hence does not necessarily reflect the optimal filter change interval plan based on your water quality.
  • Page 12 INSTALLATION MANUAL ™ AquaWave Premium Reverse Osmosis System FILTER IDENTIFIERS & TYPE • #1 K14-PP-WW: Inline PP Filter • #2 K14-GT-WW: Inline Activated Carbon Filter • #3 K14-BF-WW: Inline Activated Carbon Filter • #4 MTW-1812-75: Replacement RO membrane • #5 K12-GT-WW: Inline Activated Carbon Filter...
  • Page 13: Troubleshooting

    5 Stage Reverse Osmosis System TROUBLESHOOTING Problem RO water looks "foamy" or "milky white" Possible Cause There is air in the system Air intake in the system is normal after the first installation. From time Possible Solution to time air might enter the systems through network. This condition will return to normal after a while.
  • Page 14: Warranty

    INSTALLATION MANUAL ™ AquaWave Premium Reverse Osmosis System WARRANTY Global Water Solutions (“GWS”) warrants the product will be free of defects in material and workmanship under normal usage conditions beginning on the date of manufacture and continuing for a warranty coverage period of 1 year. Warranty applies only when the product is used for its intended purpose and does not apply if a defect is due to improper use of the product, result of accident, misuse, or abuse.
  • Page 15 Have questions or need assistance? www.globalwatersolutions.com rev 1 © 2023/06 globalwatersolutions...