Radiant RK 34/B Ekobox User Manual

Premix condensing boiler version for remote storage cylinder connection
Hide thumbs Also See for RK 34/B Ekobox:

Advertisement

Quick Links

User Manual
for model
RK 34/B Ekobox
Premix condensing boiler
version for remote storage cylinder connection
CE
0694
RK 34.B EKOBOX - RAD - ING - MAN.UT - 1305.1 - DIGITECH 2 - CBD - AUSTRALIA
Technical specification RADIANT BRUCIATORI S.p.A. Montelabbate

Advertisement

loading

Summary of Contents for Radiant RK 34/B Ekobox

  • Page 1 User Manual for model RK 34/B Ekobox Premix condensing boiler version for remote storage cylinder connection 0694 RK 34.B EKOBOX - RAD - ING - MAN.UT - 1305.1 - DIGITECH 2 - CBD - AUSTRALIA Technical specification RADIANT BRUCIATORI S.p.A. Montelabbate...
  • Page 2: General Warnings

    USER INSTRUCTIONS BOILER OPERATING INSTRUCTIONS Make sure that the authorised technician who tested the boiler has stamped the guarantee booklet. The installation, first start-up, regulation and maintenance operations must be carried out exclusively by qualified personnel. Incorrect installation can cause damage to property and injury to persons or animals, for which the manufacturer will not be held responsible.
  • Page 3 USER INSTRUCTIONS If you smell gas …  DO NOT ACTIVATE ANY ELECTRIC SWITCHES, TELEPHONES OR ANY OTHER DEVICE THAT MAY GENERATE ELECTRICAL DISCHARGES OR SPARKS.  OPEN DOORS AND WINDOWS IMMEDIATELY TO CREATE A CURRENT OF AIR THAT WILL RAPIDLY CLEAR THE ROOM.
  • Page 4: Starting - Up The Boiler

    USER INSTRUCTIONS Starting - up the boiler • Open the gas Isolation valve located under the boiler. • Switch on the boiler by placing the ON/OFF switch (1) in the ON position (see “Control panel”). • The boiler will light automatically (with the WINTER mode selected and room thermostat connected).
  • Page 5 USER INSTRUCTIONS ■ Topping-up the system with water The water pressure in the central heating circuit must be checked during the entire period of operation of the boiler. In this respect, the reading on the pressure gauge M (fig. 2), located on the lower part of the boiler, must not be less than 1 bar.
  • Page 6 USER INSTRUCTIONS Heating Sensor malfunction Code E05 lit continuously on the display. Call the Service Centre. D.H.W boiler sensor malfunction Code E12 lit continuously on the display. Call the Service Centre. Electric Fan Malfunction Code E16 lit continuously on the display. Call the Service Centre. Parameter programming request Code E22 lit continuously on the display.
  • Page 8 RADIANT BRUCIATORI s.p.a. Via Pantanelli, 164/166 - 61025 Loc. Montelabbate (PU) Tel. +39 0721 9079.1 • fax. +39 0721 9079279 e-mail: info@radiant • Internet: http://www.radiant.it TECHNICAL DATA MEASUREMENTS PROVIDED INFORMATION PURPOSES ONLY AND ARE NOT BINDING. THE COMPANY RESERVES THE RIGHT TO APPLY VARIATIONS WITHOUT PRIOR NOTIFICATION.