Figure 4-1: Lens Adjustment
Table 4-1: Lens Adjustment Description
Port Name
Focusing lever
Adjust the focus of lens, default is lock.
Adjust the lens focal length, default is
Zoom level
lock.
Figure 4-2: Multihead Cable 1
Table 4-2: Multihead Cable 1 Description
ID
Cable
Description
Connects to a standard
Ethernet cable
Network
Green light: Network
1
Access Port
connection is normal
Yellow light: Data is
being transmitted
Connects to a 12V direct
Power Supply
2
current (DC) power
(DC 12V)
supply
Long press 5 seconds to
3
Reset Button
restore original settings
Figure 4-3: Multihead Cable 2
Table 4-3: Multihead Cable 2 Description
ID
Cable
Description
1
Network
Connects to a standard
Description
Comment
Supports
PoE
Comment
Supports
Access Port
Ethernet cable
Green light: Network
connection is normal
Yellow light: Data is being
transmitted
Connects to an external
2
Audio Output
audio device (speaker)
Receives an analog audio
3
Audio Input
signal from devices such
as a microphone.
Long press 5 seconds to
4
Reset Button
restore original settings
Power Supply
Connects to a 12V DC
5
(DC 12V)
power supply
G
Alarm output COM
OUT
Alarm output terminal
6
G
Alarm input COM
IN
Alarm input terminal
5. Add Camera to VMS
Change IP Address to Static
There are some situations where an IP address
needs to be static and/or the camera password
changed. These steps are optional and do not
apply to everyone.
Camera Login
1. Open an Internet browser, enter the IP
address of the camera (default value:
192.168.0.120) in the address box, and press
Enter.
2. Input the username and password and click
the login button (default username and
password are both admin). Change the
password after logging in for the first time to
ensure system security. It is recommended to
restart the device after modifying the
password.
Set Static IP
1. After logging in to the camera, navigate to
Configuration > Device > Local Network.
2. Input the desired IP address in the IP Address
box and click Apply. After changing the IP
address setting, use the new IP address to
log in to the web interface in the future.
PoE
Applies to
cameras
with audio
function
Applied for
alarm
function

Advertisement