Your Evolve Series twin water softeners and conditioners are precision built, high quality products. These units will deliver conditioned water for many years to come when installed and operated properly. Please study this manual carefully and understand the cautions and notes before installing. This manual should be kept for future reference. If you have any...
Page 3
PRE-INSTALLATION INSTRUCTIONS The manufacturer has preset the water treatment unit’s sequence of cycles, cycle times, salt dose, exchange capacity and salt dose refill time. THE DEALER SHOULD... THE INSTALLER SHOULD... THE HOMEOWNER SHOULD... •Read this page and guide the installer •Program installer settings including hardness, •Read Programming Procedures section.
BYPASS VALVE The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control valve repairs or maintenance. The 1” full flow bypass valve incorporates four positions, including a diagnostic position that allows a service technician to have pressure to test a system while providing untreated bypass water to the building.
INSTALLATION GENERAL INSTALLATION & SERVICE WARNINGS The control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments. There is a small amount of “give” to properly connect the piping, but the water treatment unit is not designed to support the weight of the plumbing. Do not use Vaseline, oils, other hydrocarbon lubricants, or spray silicone anywhere.
Page 6
INSTALLATION 8. INSTALLING GROUND: To maintain an electrical ground in metal plumbing of a home’s SHUTOFF cold water piping (such as a copper plumbing system), install a ground clamp or jumper wiring. GROUND VALVE STRAP NOTE: If replacing an existing unit, also replace the ground clamps/wire. If removing a unit, replace the piping with the same type of piping as the original to assure plumbing integrity and grounding.
PROGRAMMING PROCEDURES: 1 . Set Time of Day Typically, time of day should only need to be set after extended power outages or when daylight saving time begins or ends or after the battery has been replaced. If an extended power outage occurs, the time of day will flash on and off indicating that the time should be reset. To set the clock: STEP 1 –...
Page 9
SERVICE ALARM PROGRAMMING PROCEDURES: – STEP 7 – ALARM BUZZER: Use the buttons to turn the alarm ON or OFF. Unit is set to ON by default. ALARM BUZZER Alarm will sound after a regeneration warning the owner of possible valve errors or other issues. This alarm is a short 0.5 second burst every 3 seconds.
START-UP INSTRUCTIONS FLUSHING OF SYSTEM: To flush the system of any debris and air after installation is complete, please perform the following steps: 1. Rotate bypass handles to the bypass mode (Fig. 2 on page 4) . 2. Turn on inlet water and check for leaks in the newly installed plumbing. 3.
OPERATING DISPLAYS AND MAINTENANCE: 1 . GENERAL OPERATION: When the system is operating, one of six displays may be shown and will alternate with the installing dealer’s name and phone number for future service. Pressing NEXT will alternate between the displays. 1.
Page 12
OPERATING DISPLAYS AND MAINTENANCE: 5 . POWER LOSS AND BATTERY REPLACEMENT: If an extended power outage occurs, the control valve will retain the time of day settings until the board’s battery is depleted. Once the battery is depleted, the display will appear dark and absent of any information. If this occurs, following these steps will determine if the problem is a low battery or a board failure.
TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION A. Depleted battery. A. See Operating Display and Maintenance section. B. Control valve power adapter not plugged into outlet B. Plug power adapter into outlet or connect or power cord end not connected to PC board power cord end to PC board connection.
Page 14
TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION A. Turn bypass handles to place bypass in A. Bypass valve in bypass position. service position. 7 . Control valve does B. Meter is not connected to meter connection on PC B. Connect meter to three pin connection labeled not regenerate board.
Page 15
TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION A. Injector is plugged. A. Remove injector and replace. B. Faulty regenerant piston. B. Replace regenerant piston. C. Regenerant line connection leak. C. Inspect regenerant line for air leak. 12 . Control valve fails to D.
Page 16
TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION 16 . E3, Err – 1003, A. Snap drive bracket in properly then Press Err – 103 = Control A. Drive bracket not snapped in properly and out NEXT and REGEN buttons for 3 seconds to valve motor ran enough that reduction gears and drive gear do not resynchronize software with piston position...
Page 17
TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION 21 . Err – 201 200 errors are only A. Invalid regeneration cycle step detected. A. Replace PC board. viewable in history screens. These do not flash when error occurs. A. Short power disruption. A. Check transformer voltage and verify power source. 22 .
Page 23
REPLACEMENT PARTS TWIN TRANSFER Item No. Part No. Description Qty. CV3470 Screw, BHC 1/4- 20 x 1 SS CV3724 Washer, flat SS 1/4 CV4005-01 T1 transfer cap assembly CV4029 O-ring 236 CV4015 T1 transfer spring CV4014 T1 transfer spring support CV4036 T1 rotor disk assembly CV3105...
Page 24
REPLACEMENT PARTS BYPASS VALVE Item No. Part No. Description Qty. CV3006 Bypass assembly CV3147 Bypass handles REFILL PORT ASSEMBLY Item No. Part No. Description Qty. CV4144 3/8” Elbow, Parker fitting CV3163 O-ring 019 CV3195-01 Refill port plug assembly CH4615 Elbow locking clip CV3395 Chlorine Generator (Black) CV3395-G...
Page 25
REPLACEMENT PARTS INJECTOR ASSEMBLIES Item No. Part No. Description Qty. CV3176 Injector cap CV3152 O-ring 135 CV3177-01 Injector screen CV3010-1Z Injector assembly plug CV3010-1A A injector assembly, ����� CV3010-1B B injector assembly, ����� C injector assembly, ������ CV3010-1C CV3010-1D D injector assembly, ��� CV3010-1E E injector assembly, �����...
Page 26
REPLACEMENT PARTS DRAIN LINE ASSEMBLY 3/4” DRAIN LINE ASSEMBLY 1” Item No. Part No. Description Qty. Item No. Part No. Description Qty. CH4615 Elbow locking clip CH4615 Elbow locking clip CPKP10TS8-BULK Optional insert, 5/8” tube CV3166 Drain FTG body 1 CV3192 Optional nut, 3/4”...
Page 27
REPLACEMENT PARTS BRINE TANK ASSEMBLY Item No. Part No. Description Qty. CG2191-84 Brine tank cover, injection molded WR CG2180 Brine tank cover, standard CH1095-01 Optional 18” diameter salt grid CH1080 Optional 24” diameter salt grid CG21833CB1C00 18” x 33” brine tank, black CG21840CB1C00 18”...
INSTALLATION FITTING ASSEMBLIES Fitting Installation Instructions • Installation fittings are designed to accommodate minor plumbing misalignments, but are not designed to support the weight of a system or the plumbing. • Slide nut on first, then the split ring and O-ring. •...
Page 29
INSTALLATION FITTING ASSEMBLIES NOTE: Not all available fi ttings are Item No . Part No . Description Qty . displayed below. Contact For All Assemblies CV3151 Nut, 1” quick connect manufacturer for optional CV3150 Split ring fi ttings. CV3105 O-ring 215 1”...
18”W x 40”H All Evolve water conditioners are pre-factory set at medium salting. Note: influent waters must be at least 3 GPG hardness and 80 TDS. A calcite or corosex unit may be needed for correct operation. Combined iron and manganese removal varies depending on the form of iron, manganese, pH and other local conditions. On waters that are pre-chlorinated or where other pre-oxidation occurs, precipitated metal oxides may form that are too fine to be filtered.
Water Conditioner and Softener Limited Warranty ® Congratulations. You have purchased one of the nest water treatment systems available. In the unlikely event of a problem due to defects in material and workmanship, Water-Right proudly warrants our Evolve Series water ® ®...
QUICK REFERENCE GUIDE: REGEN TODAY and TIME OF DAY GENERAL OPERATION MANUAL REGENERATION will flash alternately if a regeneration When the system is operating, one of six displays will be shown: NOTE: For softeners, if brine tank does is expected tonight. 1.
Page 35
QUICK REFERENCE GUIDE: ADJUST HARDNESS, DAYS BETWEEN REGENERATION, TIME OF REGENERATION AND ALARM BUZZER For initial set-up or to make adjustments, please complete the following steps. SERVICE ALARM 1. Accessed by pressing ���� and + button simultaneously 2. Adjust hardness using + and — buttons 3.
Need help?
Do you have a question about the EV1-TW and is the answer not in the manual?
Questions and answers