  • Page 1 Evolve ES Series ® Water Softeners For Models: • ES-844 • ES-948 • ES-1044 • ES-1248 • ES-1354...
  • Page 2: Table Of Contents

    Water conditioners do not remove nitrates or coliform bacteria, this requires specialized equipment. Your Evolve Series water softeners are precision built, high quality products. These units will deliver conditioned water for many years to come, when installed and operated properly. Please study this manual carefully and understand the cautions and notes before installing.
  • Page 3: Pre-Installation Instructions For Dealers

    PRE-INSTALLATION INSTRUCTIONS FOR DEALERS The manufacturer has preset the water treatment unit’s sequence of cycles and cycle times. The dealer should read this page and guide the installer regarding hardness, day override, and time of regeneration, before installation. For the installer, the following must be used: •...
  • Page 4: Bypass Valve

    BYPASS VALVE The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control valve repairs or maintenance. The 1” full flow bypass valve incorporates four positions, including a diagnostic position that allows a service technician to have pressure to test a system while providing untreated bypass water to the building.
  • Page 5: Installation

    INSTALLATION: GENERAL INSTALLATION & SERVICE WARNINGS The control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments. There is a small amount of “give” to properly connect the piping, but the water softener is not designed to support the weight of the plumbing. Do not use Vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere.
  • Page 6 INSTALLATION: should be set before installing the nut, split ring and “O” Ring. Avoid getting solder flux, primer, and solvent cement on any part of the “O” Rings, split rings, bypass valve or control valve. If the building’s electrical system is grounded to the plumbing, install a copper grounding strap from the inlet to the outlet pipe.
  • Page 7 INSTALLATION: 9. SAFETY BRINE TANK CONNECTION: Install the 3/8” O.D. polyethylene tube from the Refill Elbow to the Brine Safety Float valve in the brine tank. Connection at Refi ll Elbow on the control valve Connection at Brine Safety Float in brine tank 10.
  • Page 8: Programming Procedures

    PROGRAMMING PROCEDURES: 1. Set time of day: Time of day should only need to be set after extended power outages or when daylight saving time begins or ends. If an extended power outage occurs, the time of day will flash on and off indicating that the time should be reset. STEP 1 –...
  • Page 9: Startup Instructions

    FOR DOWNFLOW REGENERATING UNITS STARTUP INSTRUCTIONS FLUSHING OF SYSTEM: To flush the system of any debris and air after installation is complete, please perform the following steps: 1. Rotate bypass handles to the bypass mode (Fig. 2 on page 4) . 2.
  • Page 10: Operating Displays And Maintenance

    OPERATING DISPLAYS AND MAINTENANCE 1. GENERAL OPERATION: When the system is operating, one of four displays may be shown and will alternate with the installing dealer’s name and phone number for future service. Pressing will alternate between the displays. NEXT 1.
  • Page 11 OPERATING DISPLAYS AND MAINTENANCE 4. POWER LOSS AND BATTERY REPLACEMENT: If an extended power outage BATTERY REPLACEMENT occurs, the control valve will retain the time of day settings until the board’s battery is depleted. Once the battery is depleted, the display will appear dark and absent of any information.
  • Page 12: Troubleshooting Guide

    TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION A. Depleted battery A. See Operating Display and Maintenance section B. Control valve power adapter not plugged into B. Plug power adapter into outlet or connect outlet or power cord end not connected to PC power cord end to PC board connection board connection 1.
  • Page 13 TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION A. Turn bypass handles to place bypass in A. Bypass valve in bypass position service position 7. Control valve does not B. Meter is not connected to meter connection on B. Connect meter to three pin connection labeled regenerate automatically PC board METER on PC board...
  • Page 14 TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION A. Injector is plugged A. Remove injector and clean or replace B. Faulty regenerant piston B. Replace regenerant piston C. Regenerant line connection leak C. Inspect regenerant line for air leak 12. Control valve fails to D.
  • Page 15 TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION A. Check motor connections then Press NEXT and REGEN buttons for 3 seconds to resynchronize A. Motor failure during a regeneration software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect.
  • Page 16 TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION 20. Err – 109 A. Invalid motor state detected A. Replace PC board 21. Err – 201 A. Invalid regeneration cycle step detected A. Replace PC board A. Check for low flow leak. Press NEXT and A.
  • Page 17: Replacement Parts

    Black cover CV3367- 01-WR-A Gray cover CV3107-1 Motor CV3002-A Drive assembly (includes #5 and #6) – CV3813WP Evolve ES PC board CV3110 Drive gear, 12 x 36 CV3109 Drive gear cover not shown CV3186 Transformer, 110V-12V, AC (standard) not shown...
  • Page 18 REPLACEMENT PARTS: PISTON ASSEMBLY Item No. Part No. Description Qty. CV3005 1” spacer stack assembly CV3430 1.25” spacer stack assembly CV3004 Drive cap assembly CV3135 O-ring 228 CV3011 1” piston assembly downflow CV3011-01 1” piston assembly upflow CV3407 1.25” piston assembly downflow CV3174 Regenerant piston CV3001-04...
  • Page 19 REPLACEMENT PARTS BYPASS VALVE Item No. Part No. Description Qty. CV3006 Bypass assembly CV3147 Bypass handles BRINE ELBOW ASSEMBLY Item No. Part No. Description Qty. CV3195-01 Refill port plug assembly CH4615 Elbow locking clip CV4144 3/8” Elbow, Parker fitting CV3163 O-ring 019 Loosens Injector And Bypass Caps...
  • Page 20 REPLACEMENT PARTS INJECTOR ASSEMBLIES Item No. Part No. Description Qty. CV3176 Injector cap CV3152 O-ring 135 CV3177-01 Injector screen CV3010-1Z Injector assembly plug CV3010-1A A injector assembly, BLACK CV3010-1B B injector assembly, BROWN C injector assembly, CV3010-1C VIOLET CV3010-1D D injector assembly, E injector assembly, CV3010-1E WHITE...
  • Page 21 REPLACEMENT PARTS DRAIN LINE ASSEMBLY 3/4” DRAIN LINE ASSEMBLY 1” Item No. Part No. Description Qty. Item No. Part No. Description Qty. CH4615 Elbow locking clip CH4615 Elbow locking clip CPKP10TS8-BULK Optional insert, 5/8” tube CV3166 Drain FTG body 1 CV3192 Optional nut, 3/4”...
  • Page 22 REPLACEMENT PARTS BRINE TANK ASSEMBLY Item No. Part No. Description Qty. CG2191- 84 Brine tank cover, injection molded WR CG2180 Brine tank cover, standard CH1095-01 Optional 18” diameter salt grid CH1080 Optional 24” diameter salt grid CG21833CB1C00 18” x 33” brine tank, black CG21840CB1C00 18”...
  • Page 23: Installation Fitting Assemblies

    INSTALLATION FITTING ASSEMBLIES NOTE: Not all available fi ttings are displayed below. Contact manufacturer for optional fi ttings. 1” PVC MALE NPT ELBOW 3/4” & 1” PVC SOLVENT ELBOW Item Item Part No. Description Qty. Part No. Description Qty. CV3007 1”...
  • Page 24 INSTALLATION FITTING ASSEMBLIES NOTE: Not all available fi ttings are displayed below. Contact manufacturer for optional fi ttings. 1-1/4” & 1-1/2” BRASS SWEAT 1-1/4” & 1-1/2” PVC SOLVENT Item Item Part No. Description Qty. Part No. Description Qty. CV3007- 09 1-1/4 &...
  • Page 25: Specifications

    18”W x 40”H 18”W x 40”H * All Evolve ES water softeners are set at “medium salting” from the factory. Manufactured for Evolve • 1900 Prospect Court • Appleton, WI 54914 • Phone: 920-739-9401 • Fax: 920-739-9406 SPE-EV ES SOFT RevA1218...
  • Page 26: Warranty

    Water Softener Limited Warranty ® Congratulations. You have purchased one of the fi nest water treatment systems available. In the unlikely event of a problem due to defects in material and workmanship, Water-Right proudly warrants our Evolve Series water ® ®...
  • Page 27: Quick Reference Guide

    QUICK REFERENCE GUIDE GENERAL OPERATION ERROR CALL FOR SERVICE When the system is operating, one of four displays will be shown: If the display toggles between “Error” 1. Time of day/gpm ERROR and an error code (i.e. a number), call 2.
  • Page 28 Manufactured exclusively for Evolve Series Dealers at: 1900 Prospect Court • Appleton, WI 54914 Phone: 920-739-9401 • Fax: 920-739-9406 © 2018 Evolve Series All rights reserved. MAN-EV ES SOFT RevA1218...