11. Safety Recommendations – Danger Rating
DANGER RATING
www.viperwrl.com
Phone: +61 2 9636 5655
• Before attaching the Viper lubricator Collar to the cable, you must
ensure the cable winch control has been locked out and tagged.
Serious injury or death may occur should the cable winching
equipment be activated while the Viper Lubricator is being fitted to
the cable.
• When the Viper Lubricator has been assembled, attached to the
cable and anchored in position, the lubrication system can be
activated. While in operation the grease pump can generate up to
5,500 psi grease pressure. Under no circumstances should the
Viper Collar be opened, or the grease hose disconnected while
under pressure as this can cause serious injury.
• While in operation the Viper Lubricator utilises both high-pressure
air, up to 120 psi max and high-pressure grease up to 5,500 psi.
Always wear appropriate PPE (personal protective equipment)
suitable for your work environment while carrying out the cable
lubrication operation.
• Suggested PPE includes, safety glasses, leather gloves, safety
boots, long sleeved shirts, high visibility vest, hard hat and hearing
protection.
• Lubrication Engineering recommend to only use pumps, fittings,
hoses and accessories supplied or recommended by Lubrication
Engineering. All our components have been tested to ensure they
will work safely and effectively for extended duty cycles. Using non-
approved components may lead to unexpected failure of the Viper
Lubricator and/or its components causing serious injury to
maintenance personnel.