¡ To prevent condensate from returning, fit the ex-
haust pipe with a 1° gradient from the appliance.
16.8 Instructions for the air extraction mode
For air extraction mode, a one-way flap should be in-
stalled.
Notes
¡ If a one-way flap is not included with the appliance,
one can be ordered from a specialist retailer.
¡ If the exhaust air is conveyed through the external
wall, a telescopic duct should be used.
16.9 Installation
Checking the wall
1.
Check whether the wall is vertical and has sufficient
load-bearing capacity.
2.
Drill the hole depth in accordance with the length of
the screws.
The wall plugs must have a secure grip.
3.
Use the enclosed screws and wall plugs.
The enclosed screws and wall plugs are suitable for
use with solid brickwork. Use suitable fixing material
for other structures, e.g. plasterboard, porous con-
crete, poroton bricks.
4.
The maximum weight of the appliance is 40 kg.
Preparing the wall
1.
Mark a vertical centre line on the wall from the ceil-
ing to the lower edge of the appliance.
2.
Ensure that there are no electrical wires, gas pipes
or water pipes in the area where holes are to be
drilled.
3.
Use the enclosed template to mark where the
screws are to be inserted and the outline of the at-
tachment area.
4.
Drill five holes with a diameter of 8 mm to a depth
of 80 mm for the attachments and push in the wall
plugs flush with the wall.
Installing the appliance bracket
1.
Screw on the angle bracket for the flue duct.
2.
Screw on the brackets for the appliance until they
are hand-tight.
Do not firmly tighten the screws.