CMS1002W
REMOVAL AND REPLACEMENT
TRANSDUCER
1. Disconnect electrical power BEFORE removing
transducer.
2. Open bin door and locate the transducer socket.
3. Twist inner portion of transducer counter-
clockwise and push up gently.
4. Pull transponder down until plug connection is
accessible.
TRANSDUCER LOCATION
TRANSDUCER
5. Unplug transducer and remove from the
machine.
6. Reverse steps 1-5 to reassemble.
September, 1993
Page 20
CONNECTION
REMOVAL OF TRANSDUCER
SOCKET IN ICE
MACHINE BASE