Veit SF26 Operating Instructions Manual

Shirt finisher
Table of Contents

Advertisement

Quick Links

GB
Operating instructions
Translation of the original operating instructions
Shirt finisher
VEIT SF26
Read the manual carefully before starting work! Please retain the manual for future use!
SF26, Version 10, en_GB
18.07.2017

Advertisement

Table of Contents
loading

Summary of Contents for Veit SF26

  • Page 1 Operating instructions Translation of the original operating instructions Shirt finisher VEIT SF26 Read the manual carefully before starting work! Please retain the manual for future use! SF26, Version 10, en_GB 18.07.2017...
  • Page 2 This document as well as the information contained in it are protected by copyright and must not be copied as a whole or in parts or made available to third parties without the written consent of the editor. © VEIT GmbH, D-86899 Landsberg am Lech, Germany...
  • Page 3: Table Of Contents

    6.4.1 Setup instructions for sleeve tensioning device..42 Operation................43 7.1 Operating modes............43 7.2 Operating state of the machine........44 7.2.1 Operating state............44 7.2.2 Run to home position..........44 7.2.3 Run to reference position......... 44 18.07.2017 Shirt finisher VEIT SF26...
  • Page 4 13.3.2 Setup menu for the unloading station....143 13.3.3 Technical data of the unloading station....144 13.4 Cuff tuck press............145 13.4.1 Function description of the cuff tuck press..145 13.4.2 Setup for the cuff tuck press........ 145 Shirt finisher VEIT SF26 18.07.2017...
  • Page 5 13.5.2 Setup for the cuff tuck press........ 145 13.5.3 Technical data of the Basic shirt finisher....146 13.6 Saving energy............147 13.6.1 Function description for saving energy....147 13.6.2 Setup menu for energy-saving mode....147 Index................. 148 18.07.2017 Shirt finisher VEIT SF26...
  • Page 6: General Information

    The type plate indicating the serial number is on the back of the machine. In case of questions about the machine, please contact the VEIT service department. For all enquiries or orders in writing or on the phone, please always quote:...
  • Page 7: Ec Declaration Of Conformity

    General information EC declaration of conformity 1.2 EC declaration of conformity 18.07.2017 Shirt finisher VEIT SF26...
  • Page 8: Intended Use

    Other garments or Other materials than listed above or Coated materials may not be used The SF26 shirt finisher must not be used in hazardous areas. CAUTION! Danger from misuse of the SF26 shirt finisher. Unintended use may result in personal injuries, damage to the equipment or environment.
  • Page 9 Intended use The SF26 shirt finisher only requires little maintenance but is not maintenance-free. NOTICE! Maintenance Irregular maintenance may result in damage to the machine and production downtime. Observe the notes on maintenance. 18.07.2017 Shirt finisher VEIT SF26...
  • Page 10: Overview Of The Machine

    Adjustment of shoulder width Switch cabinet Cuff tensioning device, short sleeve Cuff tensioning device, long sleeve Iron Control panel Hem tensioning device Sleeve tensioning device Front hem clamp Foot pedal Retractable pressure clamp Machine frame Bust Shirt finisher VEIT SF26 18.07.2017...
  • Page 11: Function

    Intended use Function 2.2 Function The SF26 shirt finisher is designed for finishing and/or drying short- sleeve or long-sleeve garments, such as: Shirts Blouses Polo shirts Work coats Made from: Natural fibres or Synthetic fibres or blended fabrics of natural fibres and syn-...
  • Page 12: Technical Data

    Intended use Technical data 2.3 Technical data Fig. 2: Technical data Shirt finisher VEIT SF26 18.07.2017...
  • Page 13 1 x 8 mm, 0.6 MPa, (6 bar) Tab. 4: Dimensions and weight Dimensions Width, with sleeve tensioning devices extended 2470 mm, max. Depth, including condensate drain 1704 mm Height 2592 mm Weight 290 kg, approx. 18.07.2017 Shirt finisher VEIT SF26...
  • Page 14: Scope Of Delivery

    69 dB (A) Tab. 6: Consumption data Compressed air 11 l/cycle 2.4 Scope of delivery These operating instructions cover the maximum scope of delivery. The individual scope of delivery is detailed in the purchase contract. Shirt finisher VEIT SF26 18.07.2017...
  • Page 15: Safety

    Safety Safety The SF26 shirt finisher has been designed and built according to the basic safety requirements of EU Machinery Directive. WARNING! Residual hazard – Misuse or incorrect operation may result in death, serious or minor injuries, and damage to the equipment or environment.
  • Page 16: Explanation Of The Safety Notes

    (personal injuries), damage to the equipment or environment. NOTICE! The keyword NOTE is used to give advice on the usage. Disregarding these notes may result in damage to the equipment, e.g. to the machine or material. Shirt finisher VEIT SF26 18.07.2017...
  • Page 17: Explanation Of The Warning Symbols And Danger Signs

    (ESD protection or by touching a heating element/water pipe). NOTICE! Request to pay particular attention. This symbol labels the connection points for the protective con- ductor connection. Reference to external operating instructions. 18.07.2017 Shirt finisher VEIT SF26...
  • Page 18: General Safety And Warning Notes

    – The mains connection cable must only be replaced by a member of the VEIT GmbH service team or a person commissioned and instructed by VEIT GmbH. –...
  • Page 19: Built-In Safety Systems

    3.4 Built-in safety systems Prior to commissioning, the safety systems must be checked as follows at the specified intervals. Tab. 7: Interval Every day Every week Every month Every year Tab. 8: Inspection Visual inspection Function check Measurement 18.07.2017 Shirt finisher VEIT SF26...
  • Page 20 Mains disconnecting device (con- nector of the mains connection cable) Pneumatic main valve The maintenance unit containing the pneumatic main valve is located on the machine back side. Steam stop valve Condensate stop valve Warning signs Shirt finisher VEIT SF26 18.07.2017...
  • Page 21: Instructions

    3.4.1 Instructions Operating and maintenance personnel will be instructed on site by personnel of VEIT GmbH unless otherwise agreed in the purchase contract. In case of questions or uncertainties, please contact VEIT GmbH. WARNING!
  • Page 22: Safety Measures

    Authorised person A person who operates the machine on a regular basis and who has been instructed by a qualified person from VEIT GmbH, partic- ularly with regard to setting up and servicing the machine, unless agreed otherwise in the purchase contract.
  • Page 23: Safety Tests

    Safety Built-in safety systems > Safety tests 3.4.3 Safety tests Carried out by VEIT GmbH Airborne noise measurement – According to the Machinery Directive, Appendix 1 (Pos. 1.7.4/f) Testing and verification according to EN 60204-1:2006+A1:2009 (Section 19.1 – 19.6) –...
  • Page 24: Operating Areas

    SF26 shirt finisher can always be freely accessed. – Make sure that the emergency stop buttons can always be accessed. The SF26 shirt finisher has two operating areas. Shirt finisher VEIT SF26 18.07.2017...
  • Page 25 Cuff tensioning Hem tensioning device device Hem tensioning device , if necessary Front side of machine Control panel Select the program Enter the program parameters Stop the machine Machine frame Load the machine Start automatic mode 18.07.2017 Shirt finisher VEIT SF26...
  • Page 26: Potential Dangers

    – Keep your distance. – Do not touch the steam and condensate lines. – The machine must only be operated with the bust properly mounted. WARNING! Protect the machine against frost. Shirt finisher VEIT SF26 18.07.2017...
  • Page 27: Danger Zone Of The Machine

    Environmental obligations NOTICE! Prior to commissioning the machine, the operating company must ensure that the local regulations, e.g. on electric and pneumatic connections, are complied with if the company itself is responsible for setup and installation. 18.07.2017 Shirt finisher VEIT SF26...
  • Page 28: Operating And Maintenance Personnel

    Shut off the valve for steam supply and condensate return line. Depressurise the steam system by pressing the steam button on the control panel. Make sure that no steam emerges from the machine. Make sure that the machine has cooled down. Shirt finisher VEIT SF26 18.07.2017...
  • Page 29 Unplug the mains connector. Make sure that no voltage is present. Cutting off the pneumatic system Shut off the compressed air valve. Exhaust the air from the compressed air lines. Make sure that the machine is depressurised. 18.07.2017 Shirt finisher VEIT SF26...
  • Page 30: Transport And Packaging

    Transport and packaging Delivery Transport and packaging Although machines of VEIT GmbH are carefully checked and packed before being delivered, damages during transport cannot be ruled out. 5.1 Delivery Incoming inspection – Check the scope of delivery for completeness using the delivery note.
  • Page 31: Unloading And Transport To The Place Of Installation

    The machine must be secured before being transported. – Avoid shocks and pay attention to hoses on the earthing plate. There is a risk of injury and machine damage. – It is forbidden to stay under suspended loads! 18.07.2017 Shirt finisher VEIT SF26...
  • Page 32: Installation

    6.1 Setting up The machine will be set up, assembled and installed by qualified personnel of VEIT GmbH or by qualified personnel provided by the customer. In case of subsequent deliveries, the subassemblies must be disassembled or assembled by qualified personnel only.
  • Page 33: Energy Savings

    6.3 Installation 6.3.1 Power supply connection Connect the SF26 shirt finisher to the power supply system. The machine is provided with a connector. The connector must be freely accessible and must not be blocked. Direct connection without connector is not permissible.
  • Page 34 Installation Installation > Power supply connection CAUTION! Observe the input voltage. The machine must only be operated with the voltage and current indicated on the type plate. Make sure to observe the mains frequency. Shirt finisher VEIT SF26 18.07.2017...
  • Page 35 "sensitive to uni- versal current" (type B). NOTICE! Electrical connection ratings For the electrical connection ratings, please refer to . 18.07.2017 Shirt finisher VEIT SF26...
  • Page 36: Compressed Air Supply Connection

    Installation Installation > Compressed air supply connection 6.3.2 Compressed air supply connection The SF26 shirt finisher is connected to a pneumatic supply. WARNING! Pneumatic energy Pneumatic energy may lead to death or serious injuries. Even when the power supply has been disconnected, energy stored in the system may cause hazardous movement, e.g.
  • Page 37 Do not use compressed air that contains chemi- cals, synthetic oils with organic solvents, salts, caustic gases, etc. 18.07.2017 Shirt finisher VEIT SF26...
  • Page 38 Remove excessive coal dust by installing a microfilter on the input side of the valve. Large amounts of coal dust generated by the compressor may deposit in the valve and lead to mal- functions. Shirt finisher VEIT SF26 18.07.2017...
  • Page 39 0.6 MPa (6 bar) Sleeve tensioning device 0.15 - 0.4 MPa (1.5 - 4.0 bar) Cuff tensioning device 0.3 - 0.5 MPa (3.0 - 5.0 bar) Hem tensioning device 0.01 - 0.1 MPa (0.5 - 1 bar) 18.07.2017 Shirt finisher VEIT SF26...
  • Page 40: Condensate Connection

    Installation Installation > Condensate connection 6.3.3 Condensate connection The SF26 shirt finisher is connected to a condensate line using a condensate drain. The use of other condensate drains is not permitted and may lead to malfunctions. We therefore recommend using The SF26 mounting kit without CTP (for machines without cuff tuck press), order no.
  • Page 41: Steam Connection

    Installation Installation > Steam connection 6.3.4 Steam connection The SF26 shirt finisher is connected to a water steam supply. Machine working pressure 0.6 MPa (6 bar) at 158°C Internal diameter of the steam 1/2'' supply Steam must be connected according to the applicable technical regulations.
  • Page 42: Commissioning

    – Commissioning, particularly the first startup of the SF26 shirt finisher, must only be carried out by trained personnel. – Secure the SF26 shirt finisher against unau- thorised startup.
  • Page 43: Operation

    Incorrect operation may result in serious or minor injuries (personal injuries), damage to the equipment or environment. – Only adequately qualified and instructed per- sons may work on the SF26 shirt finisher. – Keep unauthorised persons away. – Service and maintenance work may only be carried out by qualified personnel.
  • Page 44: Operating State Of The Machine

    The carriage moves up until the upper reed switch is triggered and then down until the lower reed switch is triggered. After successful completion of the reference run, the machine is in home position and ready to operate. Shirt finisher VEIT SF26 18.07.2017...
  • Page 45: Manual Mode

    Automatic mode includes the following functions: Manually placing the garment when the tensioning elements are closing Automatic finishing cycle (steaming, drying) Manually removing the garment after opening the tensioning elements After garment removal, the machine is in idle state again. 18.07.2017 Shirt finisher VEIT SF26...
  • Page 46: Controls And Indicators

    Control panel The control panel including the touch panel contains all of the command elements required to operate the machine. A bracket for holding the iron is mounted to the control panel. Foot pedal Shirt finisher VEIT SF26 18.07.2017...
  • Page 47: Control Panel

    Menu for service mode Fig. 5: Operating mode screen Service mode The buttons of the selected functions are high- lighted. Grey: Function selection disabled Blue: Function inactive Yellow: Function active Fig. 6: Service mode screen 18.07.2017 Shirt finisher VEIT SF26...
  • Page 48 Fig. 9: Numeric keypad Exit keypad Delete entry Accept entry Pressing the button opens the numeric keypad with num- bers and special characters. Pressing the button opens the keypad with letters from A - P. Shirt finisher VEIT SF26 18.07.2017...
  • Page 49 Machine in idle state Pressing the button starts the the run to home position. If the following is indi- Pressing this button acknowledges cated: these messages. Warning Fault Defect 18.07.2017 Shirt finisher VEIT SF26...
  • Page 50 Save button Pressing the button saves the modifications. Operating mode Pressing the button changes to operating mode. Service mode Pressing the button changes to service mode. Confirm Pressing the button confirms the action. Shirt finisher VEIT SF26 18.07.2017...
  • Page 51 However, the function of the individual con- trol elements is identical to those of the extended menu. 7.3.1.5 Operating mode Fig. 11: Extended operating mode Fig. 12: Simplified operating mode 18.07.2017 Shirt finisher VEIT SF26...
  • Page 52 Displays and sets the manual drying time in the range 0 - 180 sec- onds. Drying time for residual moisture control Displays and sets the maximum drying time in the range 20 - 180 seconds. Shirt finisher VEIT SF26 18.07.2017...
  • Page 53 Without carriage (operation without re-stretching and without automatic travel of the carriage) Drying time (with residual moisture control option only) This button can be used to switch between the manual drying time function and the automatic residual moisture control function. 18.07.2017 Shirt finisher VEIT SF26...
  • Page 54 The sleeve tensioning devices are not active. Polo shirt The sleeve tensioning devices are not active. In addition, the front clamp is deactivated. Note: This type of garment cannot be selected if the residual moisture control option is active. Shirt finisher VEIT SF26 18.07.2017...
  • Page 55 Logged in (password level A) Fig. 15: Logged in to service mode Service mode is password-protected. The func- tions are disabled. For log-in see Ä Chapter 7.3.1.6.3 „Logging in to service mode“ on page 57. 18.07.2017 Shirt finisher VEIT SF26...
  • Page 56 Incorrectly set machine parameters may result in serious or minor injuries (personal injuries), damage to the equipment or environment. The machine parameters (service settings) must only be set by the VEIT service department or a third party engaged by VEIT GmbH. 7.3.1.6.2 Selecting the service menu...
  • Page 57 Screen calibration Customer-specific setup settings With "Pay-per-piece" option only Information level With "Pay-per-piece" option only Test level With "Pay-per-piece" option only 7.3.1.6.3 Logging in to service mode Log-in Enter password Password = USER Confirm password 18.07.2017 Shirt finisher VEIT SF26...
  • Page 58 Total runtime Displays the system runtime. Brightness Displays and sets the touch panel bright- ness. CPU temperature Displays the CPU temperature. dd-mm-jjjj Displays the current date. hh:mm Displays the time. Fig. 16: System Info (EN) Shirt finisher VEIT SF26 18.07.2017...
  • Page 59 Sets the delay time after which the tensioning elements will open after completing a finishing cycle. Time screen saver Sets the time after which the screensaver will be activated (VEIT logo). When setting to 0 s, the screensaver is deactivated. Enable Standby Option Enables or disables the standby function.
  • Page 60 The eMotion functions can be enabled or disabled here, in general. eMotion condensate system Moisture control eMotion save energy Note: The individual eMotion functions have to be additionally enabled in the corresponding eMotion setup menu. Shirt finisher VEIT SF26 18.07.2017...
  • Page 61 The higher the preset value for the drying time in the menu, the dryer the garment. Depending o the steam power/steam quality, VEIT GmbH recom- mends a tolerance time of 0 - 5 seconds. Minimum drying time The minimum drying time specifies how long the garment will be at least dried when the residual moisture control option is activated.
  • Page 62 Manual mode CAUTION! When pressing the button, the following warning note appears: "Do you want to activate manual operation? Attention!!! Security functions are limited". Accept safety note Cancel procedure Fig. 20: Manual mode touch screen (EN) Shirt finisher VEIT SF26 18.07.2017...
  • Page 63 ) residual moisture control can be cali- brated. The bust of SF26 must not be loaded with garment and the steam lines need to be connected to the system. After pressing the button, the procedure starts fully automatically and is completed after approximately 10 seconds (attention: front clamp moves up).
  • Page 64 A daily report is not created. Receiver Entry Enter the e-mail address of the recipient (e.g. client). Fig. 24: PPP-Setup D (EN) Time to Entry send Set the desired time for the report to be sent. Shirt finisher VEIT SF26 18.07.2017...
  • Page 65: Starting The Machine

    When pressing this button, a test e-mail is sent. Fig. 26: PPP-Tests A (EN) 7.4 Starting the machine Open all shut-off valves. Switch on the main switch. The control system starts. The following screen appears. 18.07.2017 Shirt finisher VEIT SF26...
  • Page 66: Program Sequence

    Pressing the button starts a reference run and sets the machine to the operational state. If the machine is not operated for one hour, the screensaver is automatically activated (VEIT logo). Touching the touch screen for a longer period exits screensaver mode. The user interface is displayed again and the operating functions can be executed again via the touch screen.
  • Page 67 The hem tensioning carriage moves up until reaching the lower edge of the shirt. The suction function is switched on. Align the front placket, pull down the shirt back such that the light barrier is able to detect the hem. 18.07.2017 Shirt finisher VEIT SF26...
  • Page 68 After completing the finishing cycle the pressure clamp moves to home position. The side stretchers move out for approximately 1 second. The hem tensioning unit moves down for approximately 10 cm. The garment can be removed. Shirt finisher VEIT SF26 18.07.2017...
  • Page 69: Switching Off The Machine

    Operation Switching off the machine 7.6 Switching off the machine Close all shut-off valves. Switch off the main switch. 18.07.2017 Shirt finisher VEIT SF26...
  • Page 70: Maintenance And Cleaning

    Ä Chapter 3.4.2 „Safety measures“ on page 22). Operating and maintenance personnel will be instructed on site by personnel of VEIT GmbH unless otherwise agreed in the purchase contract. To assure faultless operation of the machine, it is indispensable that the machine is cleaned and maintained at regular intervals.
  • Page 71: Cleaning

    Clean and remove mois- Wipe using a clean, lint- ture free cloth. Apply silicone spray Fluff filter, left and right Visual inspection Wipe using a clean, lint- free cloth. 18.07.2017 Shirt finisher VEIT SF26...
  • Page 72 Covers of bust, pressure Visual inspection Clean, wash or replace, clamps and sleeve if necessary, to achieve clamps an optimum finishing or drying result. Moving components Function check Adjust the speed in order to avoid hard impacts. Shirt finisher VEIT SF26 18.07.2017...
  • Page 73: Battery Replacement On Touch Panel Pp65

    Please replace battery immediately. Warning "01 PLC battery, Attention data loss" indicates that there only is little capacity of the PLC backup battery remaining. Replace the battery immediately. Operation can be continued. 18.07.2017 Shirt finisher VEIT SF26...
  • Page 74 If the battery is missing, data can only be stored for 10 minutes. The Veit order number for the replacement battery is 123546. For battery replacement, proceed as follows: Disconnect the supply line to the touch panel from the power supply.
  • Page 75 Mount the battery cover (Pos. 1) and tighten the screws. Reconnect power to the panel. Set the date and time again, if required. CAUTION! Lithium batteries are hazardous waste. Used bat- teries must therefore be disposed of accordingly. 18.07.2017 Shirt finisher VEIT SF26...
  • Page 76: Remedy Of Faults/Elimination Of Defects

    Damaged hose lines Qualified person Hoses not properly connected Screw connections not prop- erly installed, loose or leaking 9.1 Alarm messages on the touch screen Listed according to their priority (lowest error number = highest priority) Shirt finisher VEIT SF26 18.07.2017...
  • Page 77: Error Messages

    03 Error connection I/O-module Touch panel cannot connect to I/O If this error occurs, please contact module no. x. your VEIT subsidiary and specify the indicated I/O module number 05 Error front reed switch clamp The front position (pressing posi-...
  • Page 78 11 Error condensate temp. Temperature sensor signal of con- Check the temperature sensor external KT3 densate connection for external and replace if necessary. collar and cuff tuck press faulty. Check the wiring of the tempera- ture sensor. Shirt finisher VEIT SF26 18.07.2017...
  • Page 79 Read the error code on the fre- quency inverter; please contact your VEIT subsidiary. 20 Emergency Switch Emergency stop device was acti- Release the emergency stop vated. device. Acknowledge the error message with the "Stop" button. 18.07.2017 Shirt finisher VEIT SF26...
  • Page 80: Warning Messages

    23 PPP - GSM network not avail- GSM network disturbed By service engineer able 24 PPP - MODBUS-TCP faulty Internet router defective By service engineer 25 PPP - Mechanic Piece Counter Piece counter defective Replace the piece counter faulty Shirt finisher VEIT SF26 18.07.2017...
  • Page 81: Defect, Cause, Remedy

    Replace the defective fuse. No steam or not enough steam Check the steam supply. available Machine control system defective Check and replace, if necessary. Error messages on the touch Remove machine error. screen 18.07.2017 Shirt finisher VEIT SF26...
  • Page 82: Emergency

    Extinguishers that can be used according to fire class DIN EN 2: Powder extinguisher with ABC extinguishing powder for solids, liquids and gases Powder extinguisher with D extinguishing powder for flam- mable metals Carbon dioxide extinguisher for liquids, gases and solids Shirt finisher VEIT SF26 18.07.2017...
  • Page 83: Disassembly And Disposal

    Oils and solvents must be disposed of in accordance with the local regulations. Any resi- dues from production and cover material must be disposed of in accordance with the instructions of the material manufacturer or the local regulations. 18.07.2017 Shirt finisher VEIT SF26...
  • Page 84: Spare Parts

    Spare parts Spare parts CAUTION! Please note that only accessories and spare parts from VEIT GmbH may be used. VEIT GmbH cannot be held liable for damages resulting from using non-genuine accessories and non-genuine parts. For all enquiries or orders in writing or on the phone, please always...
  • Page 85: Spare Parts List

    Spare parts Spare parts list 12.1 Spare parts list 18.07.2017 Shirt finisher VEIT SF26...
  • Page 86 Spare parts Spare parts list Fig. 31: From 10/2016 Shirt finisher VEIT SF26 18.07.2017...
  • Page 87 Spare parts Spare parts list Fig. 32: From 10/2016 18.07.2017 Shirt finisher VEIT SF26...
  • Page 88 Spare parts Spare parts list Mounting plate for 3~/N/PE 400 V version Shirt finisher VEIT SF26 18.07.2017...
  • Page 89 Spare parts Spare parts list Mounting plate for 1~/N/PE 200 - 240 V version 18.07.2017 Shirt finisher VEIT SF26...
  • Page 90 Spare parts Spare parts list (*) with 3ph version only Shirt finisher VEIT SF26 18.07.2017...
  • Page 91 Spare parts Spare parts list 18.07.2017 Shirt finisher VEIT SF26...
  • Page 92 Spare parts Spare parts list Shirt finisher VEIT SF26 18.07.2017...
  • Page 93 Spare parts Spare parts list 18.07.2017 Shirt finisher VEIT SF26...
  • Page 94 Spare parts Spare parts list Shirt finisher VEIT SF26 18.07.2017...
  • Page 95 Spare parts Spare parts list Fig. 33: Cover until 10/2016 18.07.2017 Shirt finisher VEIT SF26...
  • Page 96 Spare parts Spare parts list Fig. 34: Cover from 10/2016 Shirt finisher VEIT SF26 18.07.2017...
  • Page 97 Spare parts Spare parts list 18.07.2017 Shirt finisher VEIT SF26...
  • Page 98 Back hem clamp Collar clamp Drawer/sliding partition Control pressure 0-6.0 bar Height adjustment for sleeve tensioning device, right Height adjustment for sleeve tensioning device, left Shoulder spreader Unloading station (option) is retrofitted at VEIT (5/2-way valve, bistable) Shirt finisher VEIT SF26 18.07.2017...
  • Page 99 Spare parts Spare parts list NOTICE! The blue side of the insert (Pos. 414) must be pointed upwards when installed with front clamp cover (Pos. 303). Fig. 35: Mounting the insert for residual moisture control 18.07.2017 Shirt finisher VEIT SF26...
  • Page 100 Y22, Y24 4834630060 Extension for 5/3-way valve Y9, Y10, Y11, Y12, Until 04/15 Y13, Y14 147262 5/2-way valve, monostable Y1, Y2, Y3, Y4, Y5, Y7, From 04/15 Y8, Y15, Y16, Y17, Y18, Y21, Y22, Y24 Shirt finisher VEIT SF26 18.07.2017...
  • Page 101 4874130020 Type AS DRV holding device 4831830110 W male stud coupling D4-G1/8" 4834630030 W connection G 1/8"-6/4, Viton 4838130400 D check valve screw connection D4 - M5 4831830100 W male stud coupling D4 - M5 18.07.2017 Shirt finisher VEIT SF26...
  • Page 102 F3, F4 4790650030 Fuse, 5 A MTR 5 x 20 (10 pcs.)** 137370 Motor bridge with TLE7209-2R 9290752080 Contactor 3RT1016-2BB41 K1, K2 9290752100 Varistor 3RT1916-1BB00 K1, K2 9280152260 Resistance R = 0.24 ohms, 25 W Shirt finisher VEIT SF26 18.07.2017...
  • Page 103 Mains filter 16 A 123546 Backup battery, touch 135697 Printed circuit board, residual moisture 143483 Counter, pay per piece 143487 Antenna 143485 Router extension FLB3202 143484 Router basic unit 9290550150 Fuse, 0.63 A MTR 5 x 20 18.07.2017 Shirt finisher VEIT SF26...
  • Page 104 Cover for front clamp 138647 138647 138647 Cover for back hem clamp from 01/06/2013 128689 128689 128689 Cover for side stretcher 152028 152160 135611 Cover for slim bust 152161 152161 152161 Cover for front clamp Shirt finisher VEIT SF26 18.07.2017...
  • Page 105: Spare Parts, Residual Moisture Control (Option)

    Return spring for swivel arm (for HRS also) 12.1.1 Spare parts, residual moisture control (option) Position Article number Designation Identifier 135697 Printed circuit board, residual moisture control 136175 Wigaflex, highly flexible, 1 mm²/yellow Wiring, front clamp 18.07.2017 Shirt finisher VEIT SF26...
  • Page 106: Spare Parts, Pay Per Piece (Option)

    Spare parts, pay per piece (option) Position Article number Designation Identifier 151134 ET - complete eWon router 143483 Counter, pay per piece 148583 Patch cable, shielded, 5 m, 85°C 143487 Router extension for GSM antenna Shirt finisher VEIT SF26 18.07.2017...
  • Page 107: Pneumatics Diagram

    Spare parts Pneumatics diagram 12.2 Pneumatics diagram 18.07.2017 Shirt finisher VEIT SF26...
  • Page 108 Spare parts Pneumatics diagram Shirt finisher VEIT SF26 18.07.2017...
  • Page 109: Circuit Diagram

    Spare parts Circuit diagram 12.3 Circuit diagram 18.07.2017 Shirt finisher VEIT SF26...
  • Page 110: Circuit Diagram 230 V

    Spare parts Circuit diagram > Circuit diagram 230 V 12.3.1 Circuit diagram 230 V Fig. 36: Circuit diagram 230 V, page 1 Shirt finisher VEIT SF26 18.07.2017...
  • Page 111 Spare parts Circuit diagram > Circuit diagram 230 V Fig. 37: Circuit diagram 230 V, page 2 18.07.2017 Shirt finisher VEIT SF26...
  • Page 112 Spare parts Circuit diagram > Circuit diagram 230 V Fig. 38: Circuit diagram 230 V, page 3 Shirt finisher VEIT SF26 18.07.2017...
  • Page 113 Spare parts Circuit diagram > Circuit diagram 230 V Fig. 39: Circuit diagram 230 V, page 4 18.07.2017 Shirt finisher VEIT SF26...
  • Page 114 Spare parts Circuit diagram > Circuit diagram 230 V Fig. 40: Circuit diagram 230 V, page 5 Shirt finisher VEIT SF26 18.07.2017...
  • Page 115 Spare parts Circuit diagram > Circuit diagram 230 V Fig. 41: Circuit diagram 230 V, page 6 18.07.2017 Shirt finisher VEIT SF26...
  • Page 116 Spare parts Circuit diagram > Circuit diagram 230 V Fig. 42: Circuit diagram 230 V, page 7 Shirt finisher VEIT SF26 18.07.2017...
  • Page 117 Spare parts Circuit diagram > Circuit diagram 230 V Fig. 43: Circuit diagram 230 V, page 8 18.07.2017 Shirt finisher VEIT SF26...
  • Page 118 Spare parts Circuit diagram > Circuit diagram 230 V Fig. 44: Circuit diagram 230 V, page 9 Shirt finisher VEIT SF26 18.07.2017...
  • Page 119 Spare parts Circuit diagram > Circuit diagram 230 V Fig. 45: Circuit diagram 230 V, page 10 18.07.2017 Shirt finisher VEIT SF26...
  • Page 120 Spare parts Circuit diagram > Circuit diagram 230 V Fig. 46: Circuit diagram 230 V, page 11 Shirt finisher VEIT SF26 18.07.2017...
  • Page 121 Spare parts Circuit diagram > Circuit diagram 230 V Fig. 47: Circuit diagram 230 V, page 12 18.07.2017 Shirt finisher VEIT SF26...
  • Page 122 Spare parts Circuit diagram > Circuit diagram 230 V Fig. 48: Circuit diagram 230 V, page 13 Shirt finisher VEIT SF26 18.07.2017...
  • Page 123 Spare parts Circuit diagram > Circuit diagram 230 V Fig. 49: Circuit diagram 230 V, page 14 18.07.2017 Shirt finisher VEIT SF26...
  • Page 124 Spare parts Circuit diagram > Circuit diagram 230 V Fig. 50: Circuit diagram 230 V, page 15 Shirt finisher VEIT SF26 18.07.2017...
  • Page 125: Circuit Diagram 400 V

    Spare parts Circuit diagram > Circuit diagram 400 V 12.3.2 Circuit diagram 400 V Fig. 51: Circuit diagram 400 V, page 1 18.07.2017 Shirt finisher VEIT SF26...
  • Page 126 Spare parts Circuit diagram > Circuit diagram 400 V Fig. 52: Circuit diagram 400 V, page 2 Shirt finisher VEIT SF26 18.07.2017...
  • Page 127 Spare parts Circuit diagram > Circuit diagram 400 V Fig. 53: Circuit diagram 400 V, page 3 18.07.2017 Shirt finisher VEIT SF26...
  • Page 128 Spare parts Circuit diagram > Circuit diagram 400 V Fig. 54: Circuit diagram 400 V, page 4 Shirt finisher VEIT SF26 18.07.2017...
  • Page 129 Spare parts Circuit diagram > Circuit diagram 400 V Fig. 55: Circuit diagram 400 V, page 5 18.07.2017 Shirt finisher VEIT SF26...
  • Page 130 Spare parts Circuit diagram > Circuit diagram 400 V Fig. 56: Circuit diagram 400 V, page 6 Shirt finisher VEIT SF26 18.07.2017...
  • Page 131 Spare parts Circuit diagram > Circuit diagram 400 V Fig. 57: Circuit diagram 400 V, page 7 18.07.2017 Shirt finisher VEIT SF26...
  • Page 132 Spare parts Circuit diagram > Circuit diagram 400 V Fig. 58: Circuit diagram 400 V, page 8 Shirt finisher VEIT SF26 18.07.2017...
  • Page 133 Spare parts Circuit diagram > Circuit diagram 400 V Fig. 59: Circuit diagram 400 V, page 9 18.07.2017 Shirt finisher VEIT SF26...
  • Page 134 Spare parts Circuit diagram > Circuit diagram 400 V Fig. 60: Circuit diagram 400 V, page 10 Shirt finisher VEIT SF26 18.07.2017...
  • Page 135 Spare parts Circuit diagram > Circuit diagram 400 V Fig. 61: Circuit diagram 400 V, page 11 18.07.2017 Shirt finisher VEIT SF26...
  • Page 136 Spare parts Circuit diagram > Circuit diagram 400 V Fig. 62: Circuit diagram 400 V, page 12 Shirt finisher VEIT SF26 18.07.2017...
  • Page 137 Spare parts Circuit diagram > Circuit diagram 400 V Fig. 63: Circuit diagram 400 V, page 13 18.07.2017 Shirt finisher VEIT SF26...
  • Page 138 Spare parts Circuit diagram > Circuit diagram 400 V Fig. 64: Circuit diagram 400 V, page 14 Shirt finisher VEIT SF26 18.07.2017...
  • Page 139 Spare parts Circuit diagram > Circuit diagram 400 V Fig. 65: Circuit diagram 400 V, page 15 18.07.2017 Shirt finisher VEIT SF26...
  • Page 140: Options

    (residual moisture control) or if the preset maximum time is reached. On the SF26, the user can therefore use the advantages of residual moisture control and time control in parallel. When set-...
  • Page 141: Setup Menu For Residual Moisture Control

    . 13.2 Heat recovery 13.2.1 Function description of the heat recovery system The heat generated during finishing, is absorbed by the heat recovery system and partly returned using a heat exchanger. 18.07.2017 Shirt finisher VEIT SF26...
  • Page 142: Technical Data Of The Heat Recovery System

    Options Heat recovery > Technical data of the heat recovery system 13.2.2 Technical data of the heat recovery system Fig. 68: Dimensional drawing of heat recovery system Shirt finisher VEIT SF26 18.07.2017...
  • Page 143: Automatic Unloading Station

    Access to the sub- menus is password-protected. Log in, see Ä Chapter 7.3.1.6.3 „Logging in to service mode“ on page 57. Press the setup button, see . Set the automatic unloading parameter option to "Yes". 18.07.2017 Shirt finisher VEIT SF26...
  • Page 144: Technical Data Of The Unloading Station

    Options Automatic unloading station > Technical data of the unloading station 13.3.3 Technical data of the unloading station Fig. 69: Dimensional drawing of unloading station Shirt finisher VEIT SF26 18.07.2017...
  • Page 145: Cuff Tuck Press

    Combined long-sleeve and short-sleeve stretchers No side vent fixing 13.5.2 Setup for the cuff tuck press The settings for the Basic shirt finisher have already been preset by the manufacturer. 18.07.2017 Shirt finisher VEIT SF26...
  • Page 146: Technical Data Of The Basic Shirt Finisher

    Options Shirt finisher Basic > Technical data of the Basic shirt finisher 13.5.3 Technical data of the Basic shirt finisher Fig. 70: SF26 Basic technical data Shirt finisher VEIT SF26 18.07.2017...
  • Page 147: Saving Energy

    Log in, see Ä Chapter 7.3.1.6.3 „Logging in to service mode“ on page 57. Press the setup button, see . Set the eMotion parameter to "Yes". Set the save energy parameter option to "Yes". 18.07.2017 Shirt finisher VEIT SF26...
  • Page 148: Index

    ........140 Operating state ......44 Shirt finisher VEIT SF26 18.07.2017...
  • Page 149 Switching off the machine ....69 System information ..... . 58 18.07.2017 Shirt finisher VEIT SF26...

Table of Contents