All safety guidelines, product descriptions, illustrations, and specifications found throughout this manual were in effect at the time the manual was released for printing. It should be noted; REED RESERVES THE RIGHT TO MAKE CHANGES IN DESIGN OR TO MAKE ADDITIONS TO OR IMPROVEMENTS IN THE PRODUCT WITHOUT IMPOSING ANY OBLIGATIONS UPON ITSELF TO INSTALL THEM ON PRODUCTS PREVIOUSLY MANUFACTURED.
OPERATION and MAINTENANCE (909)287-2100 WARRANTY REED warrants each new Concrete equipment A,B, and C Series to be free of defects in material and workmanship under normal use and service for a period as follows: CONCRETE PUMP • 1 year or 1200 operating hours, whichever occurs first •...
Failure Date: Repair Date: Do not send part(s) until requested by REED or until claim is approved. All parts requested to be returned must have a Return Authorization Number provided by REED and shipping freight prepaid. Parts must ship within 30 days from REED request.
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 SAFETY Everyone involved with the operation, maintenance, inspection, and repair of the concrete pump MUST READ and UNDERSTAND this manual and the accompanying Safety Manual. SAFETY ALERT SYMBOLS AND SIGNAL WORDS The following safety alert symbols, signals, and explanations are intended to warn the operator of hazardous and potentially hazardous situations.
OPERATION and MAINTENANCE (909)287-2100 LOCKOUT / TAGOUT The Lockout/Tagout procedure applies to all REED concrete placing equipment. Before performing any maintenance and/or repair on equipment; 1. Remove keys lock-out signage must be posted to indicate machine is currently under Lockout/Tagout.
Only Operate, Maintain, Inspect, and Repair In Accordance with This Operation Manual and the Safety Manual Performance and Safety Features Must Never Be Altered, Disconnected, or Removed Contact REED Technical Support and Service When Assistance Is Required Rev * 7 of 54...
Association (CPMA) for your protection. They are placed at appropriate areas on the concrete pump to be constant warnings of dangers. Know and adhere to the information they provide. Contact REED Customer Service for complimentary replacements of safety decals, shipping charges may apply.
Page 10
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 DO NOT OPERATE MACHINE WITHOUT ALL GRATES IN PLACE Rev * 9 of 54...
Page 11
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev * 10 of 54...
Page 12
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev * 11 of 54...
Page 13
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 DECALS PLACED NEAR HOPPER GRATE AREA Rev * 12 of 54...
Page 14
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev * 13 of 54...
Page 15
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 DECALS PLACED NEAR WATERBOX AREA DECALS PLACED NEAR OUTRIGGER CONTROL AREA Rev * 14 of 54...
Page 16
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 DECALS PLACED ON SIDE PANEL AREA Rev * 15 of 54...
Page 17
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev * 16 of 54...
Page 18
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev * 17 of 54...
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 OPERATION OPERATOR QUALIFICATIONS Everyone involved with the operation, maintenance, inspection, and repair of the concrete pump MUST READ and UNDERSTAND this operation manual and the accompanying Safety Manual. The following are a few general warnings for operator qualifications outlined in the Safety Manual.
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 PRODUCT DESCRIPTION The operation of the concrete equipment encompasses the use of hydraulic and electrical systems. This Concrete Pump is designed to safely mix wet concrete or material within its published ratings and specifications. Stability of the concrete pump during operation is provided by the ( ) outrigger legs and the front jack that can be raised or lowered from the concrete pump, to accommodate terrain.
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 CONTROLS PLC MAIN CONTROLS B, C-SERIES EMERGENCY STOP This push/pull emergency switch is used to shut down the pump in an emergency by disabling the hydraulic systems. It does not shut the engine or motor off. Depress PUSH knob in to STOP operation. PULL knob out to REACTIVATE system.
Page 24
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 PLC MAIN CONTROLS B,C-SERIES MAIN POWER KEY MAIN DIGITAL DISPLAY this is a three (3) this is where all position key switch. Turnkey to the ON position the pumping statues are displayed. to power control box. Shut down power by turning key to OFF position.
Page 25
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev * 24 of 54...
Page 26
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev * 25 of 54...
Page 27
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev * 26 of 54...
Page 28
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev * 27 of 54...
Page 29
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev * 28 of 54...
Page 30
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev * 29 of 54...
Page 31
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 Rev * 30 of 54...
Page 32
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 GAUGES PUMP or DRIVE CYLINDER GAUGE indicates the hydraulic pressure requirement of the pumping cylinders to push material. Gauge reading varies depending upon many circumstances such as: material slump, material line type, size and length, vertical, uphill, downhill or horizontal placement, pumping speed, etc.
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 JOBSITE SET-UP Refer to the Safety Manual for set-up safety precautions not limited to the following guidelines: Ensure Machine Can Be Safely Operated in Set-Up Location Away from Hazards and Dangers Away from Slopes and Excavations Position Machine on As Solid and Level Ground As Possible Adjust height of Machine and remove Leg pins Secure Machine Positions with Leg Pins and Locks...
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 PREPARING FOR SYSTEM START-UP Everyone involved with the operation, maintenance, inspection, and repair of the concrete pump MUST READ and UNDERSTANDS this manual and the Safety Manual. Refer to the Safety Manual for pumping and blockages safety precautions not limited to the following guidelines: Perform Required Inspection, Lubrication, and Maintenance Before, During, and After Pumping Operations...
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 OPERATION OF CONTROLS THE HOPPER GRATE MUST BE CLOSED (There is a safety interlock that guards against the opening of the mixer grate. SYSTEM START-UP Turn Pump ON Only When Hopper Is Full of Concrete Ensure the following conditions are met before activating pump: o PUMP Switch Is “OFF”...
Engine Manufacturer Maintenance Schedule Must Be Followed Read Engine Manufacturer Manual REED has provided only general guidelines regarding engine maintenance and will not cover engine warranty claims. Rev * 35 of 54...
Page 37
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 MAINTENANCE Hydraulic Pressure in All Systems Must Be ZERO Before and During Any Maintenance Procedures Engine Must Be Turned OFF and Lockout / Tagout Procedures Must Be Followed Before and During Any Maintenance Procedures Rev * 36 of 54...
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 GENERAL MAINTENANCE AREAS Perform scheduled inspections to identify and detect any potential problems. The list presented should be inspected and checked on a regular basis and is a recommended minimum. MAIN CONTROLS • Control box in good condition, sealed, not damaged •...
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 LUBRICATION Rapid wear and possible shutdown will result if the unit is operated with inadequate lubrication. Follow the recommendations stated herein, and if needed increase the application of lubricants above these recommendations when the equipment is subject to heavy usage.
Page 40
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 LUBRICATION POINTS The following graphics are for REFERENCE ONLY. IF EQUIPPED WITH DUAL (2) HYDRAULIC SHIFT CYLINDERS, RELIEVE SHIFT CIRCUIT HYDRAULIC PRESSURE TO PROPERLY GREASE HYDRAULIC SHIFT CYLINDERS AND BELL CRANK LUBRICATION POINTS Rev * 39 of 54...
Page 41
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 LUBRICATION POINTS S-TUBE OUTLET GREASE POINTS AGITATOR GREASE POINTS HYDRAULIC MOTOR SIDE GREASE POINTS BEARING SIDE GREASE POINTS Rev * 40 of 54...
Page 42
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 HYDRAULIC SYSTEM Hydraulic pumps are used to supply the flow of oil necessary to operate actuators of the concrete pump. Contamination of the Oil Is the Leading Contributor to System Malfunctions Extreme care must be exercised to prevent contaminants from entering the system. Always cap or plug open ports and hydraulic lines.
Page 43
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 HYDRAULIC SYSTEM MAINTENANCE ITEM DESCRIPTIONS FLUID Check fluid level and oil clarity daily with sight gauge provided. Maintain level at full mark. Add hydraulic oil through the return filter fill port when necessary. TANK BREATHER Clean every 50 hours of operation.
Page 44
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 ADDING HYDRAULIC FLUID There are a few common methods for filling the hydraulic tank as described below. Exercise extreme care when adding fluid to the hydraulic tank to avoid contamination. • To prevent any dirt or water from entering the hydraulic tank, thoroughly clean area around the return filter fill port plug, the vented fill cap or the inspection cover.
Page 45
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 FILL PORT FILTER ELEMENT GASKET RETURN FILTER Do Not Use Cloth for Straining Fluid Lint Is a Contaminant Harmful to the Hydraulic System FILTER ELEMENT O-RING Rev * 44 of 54...
Page 46
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 To change the filter elements: 1. Shut off machine. 2. VERIFY PRESSURES IN ALL CIRCUITS READ ZERO! 3. Wipe clean any dirt and grime from area surrounding filter housing 4. Loosen the filter cover plate bolts 5.
COMPONENT REPLACEMENT When parts are worn, do not delay in replacement. Continued usage with worn parts may lead to damage of other components. Please contact the REED Service Department or your local dealer for technical support. Rev * 46 of 54...
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 PUMP MAINTENANCE SCHEDULE AND CHECKLISTS Providing a maintenance schedule defined specifically by run hours or yardage pumped serves only as a general guideline given the large amount of variables a unit might be subject to, such as weather and ambient temperature conditions, jobsite conditions, material differences of mix design, the load burden the unit is typically subject to, i.e.
Page 49
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 INITIAL 50 HOUR MAINTENANCE CHECKLIST Actual Hours Date # Maintenance Description Initials Change engine oil and filters (see engine manufacturer maintenance schedule for additional requirements) IF REQUIRED Additional Notes: Change hydraulic oil filters Inspect hydraulic hoses and fittings for any signs of external wear or damage Additional Notes: Rev * 48 of 54...
Page 50
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 EVERY 100 HOUR MAINTENANCE CHECKLIST Actual Hours Date Maintenance Description Initials Clean hydraulic tank breather Inspect all structural components (check frame, hopper, and other structural members for any damage) Additional Notes: Additional Notes: Check coolers and radiators for dirt or debris. Clean as necessary Check condition of engine drive belts.
Page 51
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 EVERY 250 HOUR MAINTENANCE CHECKLIST Actual Hours Date # Maintenance Description Initials Change hydraulic filters (or change more frequently as indicated by indicator gauge on filter) Additional Notes: Check that all electrical wires, cables, terminals, plugs are in good condition Additional Notes: Change engine oil and filters (see engine manufacturer guide for all engine requirements) IF REQUIRED...
Page 52
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 EVERY 250 HOUR MAINTENANCE CHECKLIST Actual Hours Date Maintenance Description Initials Control console in good condition Switch in good condition Additional Notes: Rev * 51 of 54...
Page 53
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 EVERY 500 HOUR MAINTENANCE CHECKLIST Actual Hours Date Maintenance Description Initials Inspect hydraulic hoses and fittings for any signs of external wear or damage Additional Notes: Inspect all wear parts and change as necessary (excessive wear may cause inefficient performance and/or shutdown of operation) Additional Notes: Change hydraulic fluid, clean the reservoir and the suction strainers within...
Page 54
www.reedpumps.com OPERATION and MAINTENANCE (909)287-2100 EVERY 500 HOUR MAINTENANCE CHECKLIST Actual Hours Date ADDITIONAL GENERAL NOTES: Rev * 53 of 54...
Page 102
89113 PLC WIRING HARNESS PIN-OUT FROM DESCRIPTION WIRE SIZE/COLOR FROM DESCRIPTION WIRE SIZE/COLOR MVEC MAIN PWR V+ (BATTERY) RED 14 AWG 65 BUSS#17-3 VOLUME + B- WHT 18/19 AWG MVEC MAIN PWR V+ (BATTERY) RED 14 AWG 66 BUSS#17-4 VOLUME - B- WHT 18/19 AWG MVEC MAIN PWR V+ (BATTERY)
Page 108
TRAILER PLUG PINOUT OPEN NOT USED OPEN NOT USED #2 GREEN BLACK TAIL LIGHTS OPEN NOT USED OPEN NOT USED #2 GREEN TAIL LIGHTS #3 RED #1 BROWN #3 RED #1 BROWN LEFT TURN RIGHT TURN LEFT TURN RIGHT TURN &...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 PARTS PUMPING TRAIN ASSEMBLY WATERBOX TOP VIEW WITH OUT AGITATOR ONLY DETAIL C DETAIL B DETAIL A 4, 5, ID # PART # PART DESCRIPTION QUANTITY...
Page 112
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 PUMPING TRAIN ASSEMBLY CONTINUED DUAL SHIFT (OPTION) DETAIL D DETAIL G 300 FT-LB DETAIL F 280 FT-LB ID # PART # PART DESCRIPTION QUANTITY 86047 TIE ROD, 1" X 51½”...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 5” OUTLET SEAL KIT INSTALLATION VIEW A GROOVE IN SEAL ID # PART # PART DESCRIPTION QUANTITY 79895 SEAL KIT 77762 O-RING-#257 BUNA 90 77761 O-RING-#264 BUNA 90...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 DRIVE CYLINDER ASSEMBLY ID # PART # PART DESCRIPTION QUANTITY 86304-2 HYD CYLINDER GROUP 78961 CHECK VALVE-5K PSI O-RING 86748 FITTING-MB-MJ90-6-6 ELBOW, MB-MB90-6-6 86223HT HYDRAULIC CYLINDER 3.50 X 2.00 X 35.75...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 DUAL SHIFT BELL CRANK ASSEMBLY DETAIL E ID # PART # PART DESCRIPTION QUANTITY 86320 S-TUBE SHIFT GROUP, DUAL 85956 BELL CRANK, 3” SPLINE, DUAL 86985...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 DUAL SHIFT CYLINDER ASSEMBLY DETAIL E ID # PART # PART DESCRIPTION QUANTITY 86220HT SWING RAM-DUAL-2.50 X 5.75 STROKE 86220A-SK SEAL KIT B50HP-V25 REV A 11 of 88...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 DUAL SHIFT ASSEMBLY DETAIL E SPACE AS REQUIRED FOR PROPER S-TUBE 4 or 5 ALIGNMENT SPACE AS REQUIRED FOR PROPER S-TUBE 4 or 5 ALIGNMENT ID #...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 HOPPER AGITATOR ASSEMBLY VIEW F DETAIL F ID # PART # PART DESCRIPTION QUANTITY 86322 AGITATOR ASSEMBLY 70211 FLANGE SEAL S/W 70212 SEAL REMIXER 85978 BEARING, BALL, PLAIN...
Page 122
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 AGITATOR ASSEMBLY CONTINUED DETAIL G NOTE* Install Grove as shown VIEW G ID # PART # PART DESCRIPTION QUANTITY GREASE FITTING, 1/8” NPT STRAIT 70219 REMIX SHAFT BUSHING...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 CLEAN OUT DOOR ASSEMBLY ID # PART # PART DESCRIPTION QUANTITY 86988 DOOR WELDMENT, CLEAN OUT 86559 BLOCK, CLEAN OUT DOOR, LH 86560 BLOCK, CLEAN OUT DOOR, RH 86922 SHOULDER SCREW 1"...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 POWER TRAIN GROUP ENGINE TIER-4 ID # PART # PART DESCRIPTION QUANTITY 89552 POWER TRAIN B50/70 TIER4 140CC KAWAS 88876 ENGINE QSB4.5 130 HP CUMMINS TIER4...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 EXHAUST AFTERTREATMENT TIER4 ID # PART # PART DESCRIPTION QUANTITY BRACKET 4 CYL CUMMINS EXHAUST 74679 PLUG 1/4" NPT SOCKET HEAD 89348 HEAT BLANKET 89424 T4 ROOF HARNESS SUPPORT, C-SERIES W-114850 RUBBER BUFFER, 65X22.5X26...
Page 130
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 B50HP-V25 REV A 22 of 88...
Page 131
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 B50HP-V25 REV A 23 of 88...
Page 132
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 ID # PART # PART DESCRIPTION QUANTITY 89267 DEF COOLANT GROUP 88794-DT DEF TANK 89346 HOLD DOWN STRAP, 1” 88794-022 VALVE, DEF TANK HEATER B50HP-V25 REV A...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 DEF COOLANT GROUP ID # PART # PART DESCRIPTION QUANTITY 88794-CCV VALVE, COOLANT CONTROL, 11EA2V 89268 COOLANT MANIFOLD 89268-B MANIFOLD BRACKET 89269 BRASS FITTING, ½” NPT TO 5/8” QC 89269-1 QUICK CONNECT FITTING, 5/8”...
Page 134
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 DEF COOLANT GROUP ID # PART # PART DESCRIPTION QUANTITY DEF PUMP FILTER, DEF PUMP 88794-001 DEF HOSE, SUCTION (YELL) 88794-002 DEF HOSE, RETURN LINE (RED)
Page 135
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 DEF COOLANT GROUP ID # PART # PART DESCRIPTION QUANTITY SPARE PARTS 88794-007 AFTERTREATMENT SENSOR, NOx INLET 88794-008 AFTERTREATMENT SENSOR, NOx OUTLET B50HP-V25 REV A 27 of 88...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 TANKS FUEL TANK ASSEMBLY ID # PART # PART DESCRIPTION QUANTITY 89484 FUEL TANK ASSY B-SERIES TIER-4 89479 FUEL TANK WELDMENT, B-SERIES TIER-4 85570 FUEL CAP, 1 1/2 IN VENTED...
Page 137
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 FUEL TANK ASSEMBLY ID # PART # PART DESCRIPTION QUANTITY 10297 PLUG-GALV 1/2" (AS NEEDED) 87566 FITTING BARBED-JIC, 3/8-3/8MPT (STRAIGHT) 87567 FITTING (90 DEG) METRIC TO JIC...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 HYDRAULIC GROUP HYDRAULIC TANK ASSEMBLY ID # PART # PART DESCRIPTION QUANTITY 89554 HYD GR. B SER, TIER4, KAW 89199 HYD TANK ASSY B-SERIES 89195 HYDRAULIC TANK WELDMENT, B-TIER4...
Page 139
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 HYDRAULIC TANK ASSEMBLY CONTINUED ID # PART # PART DESCRIPTION QUANTITY 74509 GAUGE-SIGHT/TEMPERATURE 801025 DRAIN COCK, 1/4 NPT BG-12 ¾” SAE PLUG 70366 PRESSURE GAUGE, 3000 PSI/BAR...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 ELECTRICAL GROUP PROXIMITY SENSOR ID # PART # PART DESCRIPTION QUANTITY 87930 ELECTRICAL GROUP B SER 2008 CUMMINS 77998 PROXIMITY SENSOR NPN FLUSH BOX MOUT 10522...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 TEMPERTURE SENSOR HYD ID # PART # PART DESCRIPTION QUANTITY 89279 SENSOR TEMPERTURE FOR TIER4 CUMMINS 89633 ADAPTER TEMP SENSOR FOR 89279 B50HP-V25 REV A 38 of 88...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 TIER-4 MAIN WIRING HARNESS B50HP-V25 REV A 42 of 88...
Page 151
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 TIER-4 ROOF HARNESS B50HP-V25 REV A 43 of 88...
Page 152
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 ID # PART # PART DESCRIPTION QUANTITY 89052 WIRING HARNESS, B SERIES PLC TIER 4 87540 CABLE SOLENOID 88243 CABLE WITH 2 DIN PLUGS 5M 87540-1...
Page 153
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 ID # PART # PART DESCRIPTION QUANTITY 89156 DEUTSCH RECEPTACLE 128 CONTACT 89116 DEUTSCH WEDGE LOCK FOR 89109 87457 PINS, FOR 87456 BW10147 CONTACT SOCKET SIZE-16, 13 AMP, PIN...
Page 154
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 ID # PART # PART DESCRIPTION QUANTITY 89314 PLUG, APEX 150 SERIES, 24 CAVITY ID # PART # PART DESCRIPTION QUANTITY 88935 3 EAY PLUG DT SER...
Page 155
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 ID # PART # PART DESCRIPTION QUANTITY 89316 PLUG. HDSCS SERIES, 4 CAVITY GRAY 89316-3 BACKSHELL, 89315, 89316 ID # PART # PART DESCRIPTION QUANTITY 89315 PLUG.
Page 156
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 ID # PART # PART DESCRIPTION QUANTITY 89102 DEUTSCH DT06 PLUG, 2X2 89132 WEDGE,DEUTSCH FOR 89102 89102-B BOOT FOR 89102, 4 CAVITY SOCKET ID # PART #...
Page 157
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 ID # PART # PART DESCRIPTION QUANTITY 89319 RECEPTICAL, METRIPAK 150 SERIES, 6 CAVITY 89319-3 WEDGE LOCK, METRIPAK 150 CAV, FOR 89319 ID # PART #...
Page 158
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 ID # PART # PART DESCRIPTION QUANTITY 89321 PLUG, AMP SERIES, 4 CAVITY 89321-3 COVER FOR 89321 ID # PART # PART DESCRIPTION QUANTITY 89322 PLUG, BOSCH, 2 CAVITY...
Page 159
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 ID # PART # PART DESCRIPTION QUANTITY 89323 PLUG, METIPAK 150.2 SERIES, 2 CAVITY 89323-1 TERMINAL, 150 SERIES, 16-18 AWG FOR 89323 ID # PART #...
Page 160
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 ID # PART # PART DESCRIPTION QUANTITY 87456 PLUG SOCKET CONNECTOR, 8PIN ID # PART # PART DESCRIPTION QUANTITY 89217 DEUTSCH HD34 RECP, 8 PIN 88479...
Page 161
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 ID # PART # PART DESCRIPTION QUANTITY 89277 DEUTSH DT706 PLUG, 2 CAVITY 89277-A WEDGE FOR 89277 ID # PART # PART DESCRIPTION QUANTITY 88733-1 FUSE HOLDER INLINE, BLADE STYLE, 30AMP...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 SERIAL PLATE IDENTICATION Serial Plate Identification Tier version Panel serial # Display serial # Pump type Expansion module serial # PLC program Fuse/Relay box serial #...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 CAN PUSH BUTTON SWITCH PLUG SWITCH A CAN SWITCH A ID # PART # PART DESCRIPTION QUANTITY 89102 DEUTSCH DT04 PLUG, 2X2 89132 DEUTSCH WEDGE LOCK FOR 89102...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 CAN PUSH BUTTON SWITCH PLUG SWITCH B CAN SWITCH B ID # PART # PART DESCRIPTION QUANTITY 89102 DEUTSCH DT04 PLUG, 2X2 DEUTSCH WEDGE LOCK 89132...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 CAN PLUGS, CONNECTORS GREEN BLUE BLUE NOTE* GREEN-CIRCLE BLUE-TRIANGLE BLUE ENGINE CAN J1939 ID # PART # PART DESCRIPTION QUANTITY 88934 3 WAY T RECEPTICAL, DT SER.
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 DEUTSCH 128 PLUG ASSEMBLY CONTROL HARNESS SIDE ENGINE HARNESS SIDE B50HP-V25 REV A 68 of 88...
Page 177
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 DEUTSCH 128 PLUG ASSEMBLY CONT. PLUG ASSEMBLY ID # PART # PART DESCRIPTION QUANTITY 89109 DEUTSCH RECEPTACLE 128 CONTACT, PIN 89159 DEUTSCH WEDGE LOCK FOR 89157...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 FRAME INSTALLATION FRAME, TIRES, JACK, AND TOW EYE ID # PART # PART DESCRIPTION QUANTITY 89486 FRAME ASSY B SER TIER4 89485 FRAME WELDMENT 36” STROKE, TIER4 85423 TIRE &...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 HOOD AND COVERS FLUSH BOX ASSEMBLY TOP COVER BOTTOM COVER ID # PART # PART DESCRIPTION QUANTITY 89482 COVER TOP, B SER CUMMINS T4 PAINTED 89284...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 OPTIONS 3 SPOOL CONTROL VALVE DETAIL A DETAIL B DETAIL D DETAIL C ID # PART # PART DESCRIPTION QUANTITY 85706 RELIEF, CARTRIDGE 74469 DETENT KIT, #11 WALVOIL VALVE...
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 AVAILABLE OPTIONS OUTRIGGER GROUP HYD OUTRIGGER OUTRIGGER/AGITATOR ELECTRIC OUTRIGGER AGITATOR GROUP STD/PADDLE OPTION/PADDLE HYD/AGITATOR/SINGLE HYD/AGITATOR/TRIPLE RADIO REMOTE AARCOMM 2-WAY RADIO W/STROKE COUNTER AND VOLUME INDICATOR (IF EQUIPPED) 50’...
Page 194
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 CARBIDE WEAR PARTS WEAR RING/CARBIDE WEAR PLATE/CARBIDE ELECTRIC VOLUME/FLOW CONTROL RADIO CONROL OF VOLUME (IF EQUIPPED) WATER PUMP WASH PUMP INSTALL WASH PUMP ASSY VIBRATOR KIT...
Page 195
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 TIRE & WHEEL ALUMINUM 9000 LB AUTO LUBE STEEL TUBING 12 PORT PLASTIC TUBING 12 PORT MANUAL LUBE BLOCK REMOTE EMERGENCY STOP B50HP-V25 REV A 87 of 88...
Page 196
B50HP TIER4 13822 Oaks Avenue Chino, CA 91710 reedpumps.com PARTS (909) 287 - 2100 SURGE BRAKE ASSY 9000LB 2"BALL 3”PINTLE HITCH BALL 2" 2 5/16" REINFORCED HOPPER B50HP-V25 REV A 88 of 88...
Need help?
Do you have a question about the B50HP and is the answer not in the manual?