FIREPLACE INSTALLATION
2. Attach green ground wire from power
cord to blower housing using screw pro-
vided (see Figure 36). Tighten screws
securely.
3. Place blower against lower rear wall
of firebox outer wrapper with exhaust
port directed upward. The blower will
fit inside back opening and be held in
position against back wall by magnets
(see Figure 36).
4. Be certain that all wire terminals are
securely attached to terminals on blower
motor and that the screw retaining green
ground wire is tight.
5. Mount speed control box by placing plastic
control shaft through opening in switch
bracket (see Figure 37) or ignition module
bracket (see Figure 38).
6. While supporting speed control, secure
control shaft with lock nut by pushing and
turning lock nut with pliers clockwise until
it is tight against front panel. Place control
knob provided on shaft.
7. Turn on power to duplex outlet if previ-
ously turned off per the warning in column
2, page 22.
8. Plug in blower power cord.
a. If your firebox is installed as a free-
standing unit with an accessory
mantel, determine whether the power
cord will exit left side or right side of
firebox. Route power cord through exit
hole and plug power cord into a wall
receptacle near firebox.
b. If your firebox installation is recessed
and/or pre-wired, plug power cord into
duplex outlet provided. Refer to your
firebox owner's manual for instructions
on wiring duplex outlet.
CAUTION: Never touch blow-
er wheel while in operation.
9. Check to make sure that power cord is
completely clear of blower wheel and that
there are no other foreign objects in blower
wheel. Turn blower on and check for opera-
tion. Turn blower off by turning knob fully
counterclockwise before continuing.
10. Peel off backing paper and stick supplied
wiring diagram decal on firebox bottom
approximately 12" in front of blower (see
Figure 39, page 24).
116035-01J
Continued
Lower Firebox
Cavity
Side View
Spade
Terminals
Green
Ground
Wire
Figure 36 - Blower Model BK
Switch
Speed Control Control Shaft
Bracket
Locknut
Control
Knob
Figure 37 - Attaching Speed Control to
Firebox (Millivolt Models)
Speed
Control
Control
Shaft
Figure 38 - Attaching Speed Control to
Firebox (Electronic Models)
www.desatech.com
Blower Location
Magnetic
Strips
Screw
Exhaust Port
Blower
Plug-In
Duplex Outlet
(Located underneath
firebox floor against
lower right outside wall)
Duplex Outlet
Control
Knob
Locknut
Ignition
Module
Bracket