Parts List codes and pertinent industry standards should be • Maxum Series verified before installation. (RHRV-S300P, RERV-S300) 3. Use this unit only in the manner intended by the •...
Wiring Diagram (Maxum Series Unit) TC100-120 CONTROL BOARD: BLACK 120 Vac / 1 / 60Hz BLACK Optional Accessories (Not Supplied) WHITE WHITE Power Supply a) Timer Switch (TC100) Ground b) Wall Switch Ground TC100-120P c) Dehumidistat d) Time Delay Switch (TC100-120 & TC100-120P)
Wiring Diagram (cont’d) Furnace / Fan-Coil / Heat Pump Interlock: W A R N I N G Never connect a 120 volt AC circuit to the terminals of the furnace /fan-coil/heat pump interlock (Standard Wiring). Only use the low voltage class 2 circuit. Standard Interlock Wiring LO/HI Remote...
(Recommended) Note: (For Semi Ducted System only) Semi Ducted System ( For Superior / Maxum series only) • It is recommended that the furnace blower run continuously or HRV/ERV operation be interlocked Double Vent with Extruded Aluminum Grille...
HRV and ERV Typical Installations (cont’d) HORIZONTAL Note: • 30” clearance (300CFM) and 34” clearance (500cfm) is recommended for cleaning of the core/servicing the unit. • Dampers are installed for horizontal installation. For vertical installation both dampers have to be turned so they can open properly and close when there is any backdraft. •...
Drain Connection When the outside temperature drops below -5°C, the Reversomatic HRV / ERV Supply Fan cycles ON / OFF depend on the outside temperature. The exhaust fan always operates normally at all times regardless of the outside air temperature.
Air Flow Balancing Balancing Procedure It is required to have balanced air flows in an HRV/ERV. The volume of air brought in from the outside must equal the volume of air exhausted by the unit while running at normal speed. If the air flows are not properly balanced, then: •...
NOTES:- Air Flow Balancing (cont’d) P" DUCT DIAM CROSS SECTION AREA Note:(Option #2)- Only for “superior” series Ø6 Ø7 *For balancing, extension box cover plate is 0.004 0.002 6" 0.196 sq. ft. 0.006 0.003 provided with 3 holes on supply side and 3 7"...
Air Flow (CFM) Chart for Different Knob Position (cont’d) Maintenance Regular Maintenance 1. Turn the unit off and disconnect the power supply. 2. Unlatch the door and lift the door panel towards you, hold it firmly and slide it to the left. 3.
Maintenance (cont’d) Annual Maintenance Repeat steps 1 to 5 from the previous section and continue with the following steps: 1. Clean the HRV and ERV core: - Remove filters - Loosen the core locking bracket - Remove the core, carefully grip ends of core and pull evenly outward - HRV Core >...