AIT MFS 600S Operating Manual

AIT MFS 600S Operating Manual

Multi-functional domestic hot water storage tank
Hide thumbs Also See for MFS 600S:

Advertisement

Quick Links

an ideal tomorrow
Operating Manual
Multi-functional domestic hot water storage tank
MFS 600 S, MFS 830 S, MFS 1000 S
Accessory for heat pumps
www.aitgroup.com
UK
83017400eUK

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MFS 600S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AIT MFS 600S

  • Page 1 an ideal tomorrow Operating Manual Multi-functional domestic hot water storage tank MFS 600 S, MFS 830 S, MFS 1000 S Accessory for heat pumps www.aitgroup.com 83017400eUK...
  • Page 2: Table Of Contents

    MFS 830 S ............14 MFS 1000 S ............15 Installation plan ........... 16 Hydraulic connections ........17 Variant 1 ............17 Variant 2 ............18 Legend hydraulic diagram ........ 19 Subject to change without notice | 83017400eUK | ait-deutschland GmbH...
  • Page 3: About This Operating Manual

    ● Listing Secure connections against twisting Safety-relevant information. Warning of physical injuries. Flammable materials / flammable (primary) refrigerant Safety-relevant information. Warning of physical injuries. Flammable materials / flammable (primary) refrigerant Subject to change without notice | 83017400eUK | ait-deutschland GmbH...
  • Page 4: Intended Use

    During the warranty and guarantee period, service altered, modified or removed without the ex- work and repairs may only be carried out by personnel plicit written consent of the manufacturer. authorised by the manufacturer. Subject to change without notice | 83017400eUK | ait-deutschland GmbH...
  • Page 5: Personal Protective Equipment

    NOTE Please contact your dealer about all matters concerning warranties and guarantees. Disposal When decommissioning the unit, always comply with applicable laws, directives and standards concerning recovery, recycling and disposal. Subject to change without notice | 83017400eUK | ait-deutschland GmbH...
  • Page 6: Scope Of Delivery

    EHZ 60 ● ● ● EHZ 75 ● ● ●  “Technical data, weight” overview. EHZ 90 ● ● ● ● : suitable combination, n.g. : not suitable Subject to change without notice | 83017400eUK | ait-deutschland GmbH...
  • Page 7 All parts of the insulation must be carefully removed and put aside so that they are not damaged. Remove the protective transport sheeting. Remove both insulation shells and put them in a safe place. Subject to change without notice | 83017400eUK | ait-deutschland GmbH...
  • Page 8: Installation

    Grommets IMPORTANT The zip must be closed by two people to relieve the strain. b) Sleeve Subject to change without notice | 83017400eUK | ait-deutschland GmbH...
  • Page 9: Installing The Hydraulic Connections

    Seal the two threads (1 and 2). Stretch the flexible corrugated pipe and insert the seal between the elbow and the flexible corrugated pipe. Subject to change without notice | 83017400eUK | ait-deutschland GmbH...
  • Page 10: Insulate The Circulation Connection

    The safety drain of the safety valve must lead into the drain via a funnel siphon in accordance with the applicable standards and regulations. Subject to change without notice | 83017400eUK | ait-deutschland GmbH...
  • Page 11: Installating The Sensors

    Position the sensor on the outside of the sensor spring. 1 Sensor spring 2 Sensor 3 Sensor pocket (is already installed in the tank) Subject to change without notice | 83017400eUK | ait-deutschland GmbH...
  • Page 12: Technical Data

    • yes – no – | • – | • – | • *) for further details see dimensional drawing | Manufacturer: ait deutschland GmbH | Index: a 813605 813606 813607 Subject to change without notice | 83017400eUK | ait-deutschland GmbH...
  • Page 13: Dimensional Drawings

    11/4" IG | 11/4" IG (both can be replaced) Sensor pocket (Solar) Ø 13x75 Cold water inlet 1" AG Sensor exchanger return 1" IG Return of second heat generator (draining) 11/2" IG Subject to change without notice | 83017400eUK | ait-deutschland GmbH...
  • Page 14: Mfs 830 S

    11/4" IG | 11/4" IG (both can be replaced) Sensor pocket (Solar) Ø 13 x 100 Sensor exchanger return 1" IG Cold water inlet 1" AG Return of second heat generator (draining) 11/2" IG Subject to change without notice | 83017400eUK | ait-deutschland GmbH...
  • Page 15: Mfs 1000 S

    11/4" IG | 11/4" IG (both can be replaced) Sensor pocket (Solar) Ø 13 x 100 Sensor exchanger return 1" IG Cold water inlet 1" AG Return of second heat generator (draining) 11/2" IG Subject to change without notice | 83017400eUK | ait-deutschland GmbH...
  • Page 16: Installation Plan

    Draufsicht Keys: UK819397 MF Mindestfläche um Betriebsfähigkeit und Service sicher zu stellen All dimensions in mm. Storage tank Speicher Top view Minimum area to ensure ability to operate and service Subject to change without notice | 83017400eUK | ait-deutschland GmbH...
  • Page 17: Hydraulic Connections

    Variant 1 Hydraulic connection MFS max. 20 m² max. 15 KW ZWE 2 ZWE 1 J 62 833308 / Code 218 Subject to change without notice | 83017400eUK | ait-deutschland GmbH...
  • Page 18: Variant 2

    Hydraulic connection MFS Variant 2 max. 20 m² max. 15 KW ZWE 2 ZWE 1 J 62 833308U / Code 217 Subject to change without notice | 83017400eUK | ait-deutschland GmbH...
  • Page 19: Legend Hydraulic Diagram

    Subject to change without notice | 83017400eUK | ait-deutschland GmbH...
  • Page 20 GmbH Industriestraße 3 95359 Kasendorf Germany T +49 9228 / 99 06 0 F +49 9228 / 99 06 149 E info@ait-deutschland.eu www.aitgroup.com Member of NIBE Group.

This manual is also suitable for:

Mfs 830sMfs 1000s

Table of Contents