AIT MFS 600S Operating Manual

AIT MFS 600S Operating Manual

Multi-functional domestic hot water tank
Hide thumbs Also See for MFS 600S:

Advertisement

Quick Links

Accessories for
heat pumps
Operating Manual
Multi-functional domestic hot water tank
MFS 600 S, MFS 830 S, MFS 1000 S
UK
83017400cUK – Translation of the original operating manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MFS 600S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AIT MFS 600S

  • Page 1 Accessories for heat pumps Operating Manual Multi-functional domestic hot water tank MFS 600 S, MFS 830 S, MFS 1000 S 83017400cUK – Translation of the original operating manual...
  • Page 2: Please Read First

    Adhere to the given sequence. ● Single-step instruction for action ● List Reference to further information elsewhere in  the operating manual or in another document. Subject to change without notice | 83017400cUK – Translation of the original operating manual | ait-deutschland GmbH...
  • Page 3: Table Of Contents

    Installation plan for all storage tanks ....... 15 Hydraulic connections Variant 1 ............. 16 Variant 2 ............. 17 Legend hydraulic diagram ........18 EC Declaration of Conformity ........19 Subject to change without notice | 83017400cUK – Translation of the original operating manual | ait-deutschland GmbH...
  • Page 4: Intended Use

    There is a risk of cutting your hands on sharp edges of the unit. ► Wear cut-resistant protective gloves during trans- port. Subject to change without notice | 83017400cUK – Translation of the original operating manual | ait-deutschland GmbH...
  • Page 5: Customer Service

    ● : suitable combination, n.g. : not suitable  For details of the quantity and positioning of the heating element sockets, refer to the dimensioned drawing of the respective tank. Subject to change without notice | 83017400cUK – Translation of the original operating manual | ait-deutschland GmbH...
  • Page 6: Transport, Installation, Assembly

    This can result in personal injuries and damage. ► Take suitable precautions, which pre- vent the tipping hazard. Subject to change without notice | 83017400cUK – Translation of the original operating manual | ait-deutschland GmbH...
  • Page 7: Installation

    WARNING! Make sure you secure the tank against slipping during transport. Always secure the tank on the hand truck with a ratchet strap! Subject to change without notice | 83017400cUK – Translation of the original operating manual | ait-deutschland GmbH...
  • Page 8: Circulation Kit Installation

    Replace the tank cover and push the grommets over the corresponding pipe connections. Seal the thread of the flexible corrugated pipe and screw into the tee. Subject to change without notice | 83017400cUK – Translation of the original operating manual | ait-deutschland GmbH...
  • Page 9: Insulate The Circulation Connection

    CAUTION shown in the hydraulic diagram. Tighten the union nut carefully to prevent dam-  Hydraulic connection age to the seal! Subject to change without notice | 83017400cUK – Translation of the original operating manual | ait-deutschland GmbH...
  • Page 10: Sensor Installation

     Sensor connection as shown in the “terminal dia- gram of the respective heat pump type”. Subject to change without notice | 83017400cUK – Translation of the original operating manual | ait-deutschland GmbH...
  • Page 11: Technical Data

    20 l/min drawn off at 45°C 10 l/min drawn off at 38°C 20 l/min drawn off at 38°C Manufacturer: ait deutschland GmbH 813575 Subject to change without notice | 83017400cUK – Translation of the original operating manual | ait-deutschland GmbH...
  • Page 12: Dimensional Drawings

    Sensor pocket (Solar) Ø 13x75 Sensor exchanger return 1" AG Cold water inlet 1" IG Return of second heat generator (draining) 11/2" IG Subject to change without notice | 83017400cUK – Translation of the original operating manual | ait-deutschland GmbH...
  • Page 13: Mfs 830 S

    Sensor pocket (Solar) Ø 13 x 100 Sensor exchanger return 1" IG Cold water inlet 1" AG Return of second heat generator (draining) 11/2" IG Subject to change without notice | 83017400cUK – Translation of the original operating manual | ait-deutschland GmbH...
  • Page 14: Mfs 1000 S

    Sensor pocket (Solar) Ø 13 x 100 Sensor exchanger return 1" IG Cold water inlet 1" AG Return of second heat generator (draining) 11/2" IG Subject to change without notice | 83017400cUK – Translation of the original operating manual | ait-deutschland GmbH...
  • Page 15: Installation Plan For All Storage Tanks

    MF Mindestfläche um Betriebsfähigkeit und Service sicher zu stellen Storage tank Speicher Top view Minimum area to ensure ability to operate and service Subject to change without notice | 83017400cUK – Translation of the original operating manual | ait-deutschland GmbH...
  • Page 16: Variant 1

    Variant 1 Hydraulic connection MFS max. 20 m² max. 15 KW ZWE 2 ZWE 1 J 62 833308 / Code 218 Subject to change without notice | 83017400cUK – Translation of the original operating manual | ait-deutschland GmbH...
  • Page 17: Variant 2

    Hydraulic connection MFS Variant 2 max. 20 m² max. 15 KW ZWE 2 ZWE 1 J 62 833308U / Code 217 Subject to change without notice | 83017400cUK – Translation of the original operating manual | ait-deutschland GmbH...
  • Page 18: Legend Hydraulic Diagram

    Subject to change without notice | 83017400cUK – Translation of the original operating manual | ait-deutschland GmbH...
  • Page 19: Ec Declaration Of Conformity

    EN 12897:2016 Company: Place, date: Kasendorf, 11.07.2019 ait-deutschland GmbH Industrie Str. 3 93359 Kasendorf Germany Signature: Jesper Stannow UK818177c Head of Heating Development Subject to change without notice | 83017400cUK – Translation of the original operating manual | ait-deutschland GmbH...
  • Page 20 GmbH Industriestraße 3 D-95359 Kasendorf www.ait-deutschland.eu...

This manual is also suitable for:

Mfs 830sMfs 1000s

Table of Contents