Components - Honeywell HW4000 Owner's Manual

Portable electrical generator
Hide thumbs Also See for HW4000:
Table of Contents

Advertisement

Available languages

Available languages

COMPONENTS

Use information provided in this section to become familiar with your generator's components.
The information below is provided for reference only. Refer to "OPERATION" on page 13 for instructions on
CAUTION
operating the generator.
J
H
G
F
A—Power Control Center
Household Outlets
120V 20 Amp Duplex (NEMA 5-20R)
outlets to connect 120V appliances
to generator for power.
Generator Cord/ Transfer Switch
120V 20 Amp Twist-Lock outlet can
be used to:
Power 240V appliances using
appropriate (NEMA L14-20R)
power cord (not included).
Connect a transfer switch to building's main electrical sys-
tem for back-up power (see page 10).
Breakers
Protects circuits from damage caused by
overload or short-circuit by stopping the flow
of electricity from the generator to the appli-
ance. Master circuit breaker controls power
to all outlets. If there is no power at outlets,
see Troubleshooting section.
Ground Terminal
Connects generator to ground wire for grounding protection.
Generator must be grounded to prevent electrical
shock from faulty appliances. See page 10.
B—Engine Oil Fill Cap/Dipstick
Seals off engine oil fill hole and provides indicator for engine
oil level.
C—Engine Oil Plug
When loosened, allows engine oil to drain from generator.
HW4000/HW4000L Portable Electrical Generator Owner's Manual
I
D
B
E
C
FIGURE 16: HW4000L Portable Generator
POWER CONTROL CENTER
HOUSEHOLD
4-IN-1POWER CORD
OUTLETS
TRANSFER SWITCH
120 VOLTS AC
120/240 VOLTS AC
BREAKER
BREAKER
4000
242cc
PORTABLE GENERATOR
5500 CONTINUOUS WATTS • 9375MAXIMUM WATTS
Set Tripped
CAUTION
A
D—Engine Control Switch
Control used to run and stop the engine. Engine switch has
two positions:
OF
RUN—Prepares engine to start
STOP—Stops generator engine
E—Recoil Starter Grip Handle
MASTER
BREAKER
Starts engine.
F—Fuel Valve
Controls flow of fuel from fuel tank to carburetor.
G—Air Cleaner Assembly
Removes dust from engine intake air.
H—Choke Control
Controls choke valve. Choke control must be pulled out to ON
position when starting a cold engine.
I— Fuel Gauge
Indicates level of fuel currently in fuel tank.
J—Fuel Tank Cap
Provides a secure seal on fuel tank.
K—Muffler Equipped with Spark Arrester
Provides outlet for engine exhaust. Prevents sparks and other
combustible materials from escaping generator.
Muffler reaches temperatures that can cause serious
burns if touched. NEVER touch hot surfaces.
L—Spark Plug Cap (Wire)
Delivers voltage to spark plug. When spark plug needs ser-
vice, cap must be removed.
M—Carbon Canister (HW4000L model only)
Reduces hydrocarbon emissions.
K
WARNING
www.honeywellgenerators.com
L
M
11