Single loop dimensions:
Amplifier dimensions (W x H x D):
Frequency range:
Average noise level (without loops):
IP3:
IP2:
MHz
Maximum output voltage:
Supply via HF cable:
Power supply:
HF output:
Weight:
Environmental conditions:
Compliance:
Specifications RLAGS (only deviating from 4G)
Single loop dimensions:
Frequency range:
Weight:
Changes are reserved in the course of technical development!
VERSION
DATE
1.4
24.11.2021
Specifications RLAG
About 500 mm x 500 mm
140 mm x 60 mm x 120 mm (without connectors)
50 kHz ... 30 MHz
<= -145 dBm/Hz (at 10 MHz)
>= +32 dBm (2x -6 dBm measuring tone at 10 MHz)
>= +80 dBm (10.0 MHz + 10.2 MHz -6 dBm measuring tone, 0.2
measured difference tone)
>= 1 V
, 1 dB compression
eff
+6.0 V ... +13.8 V, maximum +14.4 V!
max. 80 mA
BNC 50 ohm
<= 1.5 kg
-20 ... +40 °C ambient temperature, <=100 % rel. humidity
IP65 (with connected loops and connection cable)
CE according to DIN EN 55013, EN 55020, EN 60065
RoHS / WEEE Directive, ear-Reg. 27676700
Diameter horizontal approx. 770 mm
Height incl. housing approx. 690 mm
20 kHz ... 30 MHz
<= 2.0 kg