Download Print this page

Samsung MWR-WE11N Installation Manual page 9

Hide thumbs Also See for MWR-WE11N:

Advertisement

Group Control with Your Wired Remote Controller
Group control means that you are using one Wired Remote Controller to control two or more indoor units and
ventilator(ERV) at the same time.
When Connected to an Indoor Unit Only
(1) Using One Wired Remote Controller to control three indoor Units
Outdoor Unit
COM1(F1, F2)
Indoor Unit
Wired Remote
Controller
(2) U sing One Wired Remote Controller to control indoor units connected to different outdoor unit
Outdoor Unit
COM1(F1, F2)
Indoor Unit
Outdoor Unit
COM1(F1, F2)
Indoor Unit
• R egardless of the indoor unit's group address (RMC address), only the indoor units connected to COM2 are
controlled in group.
• Regardless of your outdoor units, you can control a maximum of 16 indoor units as a group.
• A ddress of each outdoor units must be set differently when group control indoor units connected to the other
outdoor unit.
COM1(F1, F2)
COM2(F3, F4)
COM2(F3, F4)
COM2(F3, F4)
COM1(F1, F2)
Indoor Unit
COM2(F3, F4)
Wired Remote
Controller
Indoor Unit
9

Advertisement

loading