ILLUMINATED TISSUE FLOTATION BATH - BK200

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BK200 and is the answer not in the manual?

Questions and answers

Summary of Contents for Mopec BK200

  • Page 1 MOPEC USER MANUAL ILLUMINATED TISSUE FLOTATION BATH - BK200...
  • Page 2: Table Of Contents

    WARRANTY TERMS AND CONDITIONS INTRODUCTION Mopec’s Illuminated Tissue Flotation Bath features an LED light and high-contrast background that allows users to better view tissue sections while also detecting foreign particles floating on the surface of the water. The LED light is dimmer controlled and can be switched between white or blue.
  • Page 3: General Notes

    The system features an optional lid to cover the bowl when not in use. The lid not only improves temperature control, but also prevents particle from settling on the surface of the water. GENERAL NOTES 1. This product is designed for laboratory use only. Always follow good laboratory practice. 2.
  • Page 4: User Safety

    SPECIFICATION The Mopec Illuminated Tissue Flotation Bath is designed with both reliability and ease of use in mind. Digital temperature control accurately maintains water at a set temperature, which enables tissue sections to be efficiently flattened prior to being picked up with a microscope...
  • Page 5: Location

    The bath has generous space for a user to rest their hands when floating sections and an extra deep tapered bowl which allows slides to be dipped at any angle, without touching the bottom of the bowl. Stability is provided by four rubber feet and controls have been recessed to provide the user with an added measure of safety.
  • Page 6: Cleaning Instructions

    2. Connect the mains plug to the electrical supply and switch on. (Ensure the power supply is properly earthed). 3. Turn on the tissue section bath. 4. Select the desired temperature. a. Press the DOWN arrow then release it (do not hold the DOWN arrow for 5 seconds).
  • Page 7: Miniature Circuit Breakers

    4. Mopec will accept no liability, where in the opinion of the company the defect has been caused by damage due to the Customers failure to follow operating instructions, correct...
  • Page 8 6. Any goods or parts thereof, which may require repair or replacement, shall be repaired or replaced (at the election of Mopec) at the works of Mopec. The product to be repaired shall be delivered to Mopec by the customer at the Customer’s risk and expense. Any such goods or parts will be delivered by Mopec to the Customer free within the United States but if required to be borne by the Customer.
  • Page 9 800 Tech Row Madison Heights, MI 48071 EC DECLARATION OF CONFORMITY We herewith confirm the following products: Illuminated Tissue Flotation Bath - BK200 Conforms with requirements outlined by the following European Directives: Low Voltage Directive 2006/95/EEC EMC Directive 2004/108/EEC We confirm the declaration:...
  • Page 10 ROUTINE INSPECTION RECOMMENDATIONS Mopec recommends that a simple annual inspection be made for all Mopec laboratory appliances in order that any malfunction can be identified and rectified as early as possible. This is to ensure user safety and prolong instrument lifespan.