E80390 E80391 RFID antenna adapter 2 Safety instructions General • The unit described is a subcomponent for integration into a system. – The system architect is responsible for the safety of the system. – The system architect undertakes to perform a risk assessment and to create documentation in accordance with legal and normative requirements to be provided to the operator and user of the system.
E80390 E80391 3 Intended use The articles E80390 and E80391 are accessories for the M18 and rectangular type RFID read/write heads. The accessories are used to change the field of the connected RFID read/write heads. This leads to the following effects depending on the installation of the accessories: •...
E80390 E80391 RFID antenna adapter 4 Installation 4.1 Installing E80390 E80390 is suitable for being installed on an M18 type RFID read/write head (e.g. DTM424 / DTM425). There are two ways to install the E80390: • Installation to a mounted RFID read/write head (Ò...
E80390 E80391 w Use a maximum tightening torque of 0.6 Nm. u Use the mounting holes ① to fix the E80390 to a suitable surface. u Additionally fasten the RFID read/write head. w For a permanently reliable installation, the RFID read/write head is additionally fastened to a suitable surface using the M18 thread.
E80390 E80391 RFID antenna adapter 5 Technical data 5.1 E80390 detection range The figure below shows the detection zone of an ANT421 with and without E80390. A 50 mm tag (E80384) was used for the measurement. [mm] ① ANT421 with E80390 ②...
6 Maintenance, repair and disposal The unit is maintenance-free. u Contact ifm in case of malfunction. u Do not open the housing as the unit does not contain any components which can be maintained by the user. The unit must only be repaired by the manufacturer.
E80390 E80391 RFID antenna adapter 7 Approvals/standards For approvals and standards, the following information is available: • Test standards and regulations: documentation.ifm.com • EU declaration of conformity and approvals: documentation.ifm.com • Notes relevant for approval: Package insert of the device and...