  • Page 1 Operating Instructions Digital Blood Pressure Monitor EW-BU58N011 Model NO. Thank you for purchasing our products. Please read these in structions carefully before using Version: NO.01.1 this product, and save this manual for future use. Issued date: March 2023...
  • Page 2: Table Of Contents

    • Specifications • About each instruction Product name: Digital Blood Pressure Monitor Model: EW-BU58N011 Structure and composition: It is composed of a main unit and a cuff Scope of application: This product can measure diastolic blood pressure, systolic blood pressure and pulse rate of human body by oscillometry, and its values are for diagnostic reference.
  • Page 3: How To Take A Proper Measurement

    How to take a proper measurement Relax for 4~5 minutes before measurement and be sure to take the measurement in a relaxed state. The posture and physical condition of the user will affect the blood pressure measurement. Wrap the Measuring posture Align the height cuff around of the cuff to...
  • Page 4: Product Functions

    Product functions: Please confirm the function of purchased product EW-BU58N011 Hypertension flash ● Memory number 90 times × 1 person Movement warning ● Irregular pulse ● Morning and evening comparison ● Clock function ● Voice function ● Backlight function ●...
  • Page 5: Safety Precautions

    Safety precautions ※Before use, please read these [Safety Precautions] carefully for proper use. ※To prevent users from suffering harm or loss due to improper use, please refer to the [Safety Precautions] and use this device correctly. For safety reasons, be sure to observe these safety precautions. indicates the contents of caution and warning.
  • Page 6 Warning Please do not allow children or people who can't express their self-awareness to use this device. While measuring with this device, do not use the unit on an arm where a catheter has been inserted. Otherwise, it may cause an accident. Forbid Do not spill water on the main unit.
  • Page 7 Be sure to please contact the After-sales Service Office designated observe by Panasonic Appliances (China) Co., Ltd. to consult the maintenance methods or ask for maintenance information. Caution: If the device needs to be repaired for various reasons, please contact the After-sales...
  • Page 8 Please note that ※During the measurement process, do not use devices that generate electromagnetic interference near this product, such as mobile phones, as the strong radiation field generated by such devices will interfere with the normal use of the product. Otherwise, this product may cause mis-operation or inaccurate measurement.
  • Page 9: Parts Identification

    Parts identification Structure and composition: Please confirm Main unit The product is composed of a main unit and a cuff. the product Display Cuff socket Bottom Battery cover Loudspeaker Operation hole part (see below) Operation part Time button Forward button Backward button Voice button Memory/Recall button...
  • Page 10 Parts identification Cuff Anti-curling fastener Cuff plug Tube Velcro fastener Includes Pouch Batteries For test run Backlight display About backlight function: The device has backlight function. When measuring and calling up the measured value, the backlight displays.  If the display is facing the light, sometimes the user cannot see the display clearly when looking from the right angle.
  • Page 11 Parts identification Display See the following table Memory number/Date/ Time identification Systolic blood pressure Indicates the systolic Pulse mark blood pressure value Indication of the detected pulse during measurement Diastolic blood Battery indicator pressure Indicates the diastolic Indication when the battery is out of power blood pressure value Voice mark...
  • Page 12: Preparation

    Batteries last for approx. 300 times, which is 3 times/day for 3 months (when using a pack of new Panasonic zinc carbon batteries). (Under the condition that the room temperature is 23 °C, 22.7 kpa (170 mmHg) pressured, and the circumference of upper arm is 30cm.)
  • Page 13: Setting The Time And Date

    Preparation Power-on prompt Power-on prompt Note: When the product is under standby mode, “0” will be displayed on the monitor. This is a normal condition, not malfunction. Preparation Setting the time and date Set in the power-off state. When using or replacing the batteries for the first time, please reset the date and time.
  • Page 14 Preparation Setting the time and date The setting of date/time cannot be completed in the following circumstances • When no operation is made for more than 1 minute and 30 seconds during the setting process. • When the [minute] setting is completed, the button is not pressed.
  • Page 15: Setting The Volume Adjustment

    Preparation Setting the time and date Set the [minute] Press button Press button to complete •The display disappears after 10 seconds Alternate display every 2 seconds Preparation Setting the volume adjustment During measurement and other operations, the volume cannot be adjusted. Press the button to adjust the volume.
  • Page 16: Before Measurement

    Preparation Before measurement For correct measurement, please read the following key points carefully, and observe the exact environment and posture. Please refer to P3 (How to take a proper measurement). Measuring time The blood pressure is constantly changing throughout the day. Therefore, take the period with the least movement after getting up and before sleeping as the measuring time.
  • Page 17 Preparation Before measurement Posture Method of cuff wrapping Do not lean forward Do not wrap the cuff on your clothes When the abdomen is stressed, the blood The pressure of the cuff pressure will rise. cannot be transmitted to the blood vessels and the blood pressure will rise.
  • Page 18: Wrapping The Cuff

    Preparation Wrapping the cuff ※Be sure to use a dedicated cuff It can be wrapped on either left or right arm for measurement. Take the measurement of left arm as an example. The measurement results of the left and right arms may vary to different extent due to different conditions of each user.
  • Page 19 Preparation Wrapping the cuff Hold down the hook and loop fastener and wrap the cuff with a gap of 1 or 2 fingers. •If the Velcro fastener is curled, fix it Anti-curling with the anti-curling fastener fastener Velcro fastener Velcro fastener If it is wrapped too loose, the cuff will swell and inflate, and the blood vessel will be locally tightened, which will cause an indication error, and the measured value will tend to rise...
  • Page 20: Operating Instructions

    Operating instructions Start measurement With the power off, press the button. After the display is fully lit, the cuff will be pressurized and measurement will be taken automatically Voice prompt (cantonese) “Please relax and then start measurement in proper posture” Note: When the pressurization value is more than 280 mmHg, the cuff will automatically exhaust.
  • Page 21 Operating instructions Start measurement Press the button to store the measured value. Memory No. Date Memory Year Time SYS. Alternate display every DIA. 2 seconds Pulse /min Press the button and take off the cuff. Press the On/Off button for about 5 seconds to switch measuring methods of mmHg and kPa.
  • Page 22: Call-Up Of Measured Values

    Operating instructions Call-up of measured values Call up the recorded measured value and average value for confirmation When the power is turned off, you can directly press the button to call up the latest measured value. Voice prompt (cantonese) : ①When the date is not set, “Systolic blood pressure: XX mmHg;...
  • Page 23 Operating instructions Delete all the memorized measured values The memorized measured values can all be deleted. But they cannot be deleted one by one. When the power is turned off, you can directly press the Alternate button to call up the display every latest measured value.
  • Page 24: About Each Instruction

    Operating instruction About each indication As the basis of correct measurement, there are movement warning and irregular pulse warning. After the signal is displayed, the correct measured value may not be obtained. After the measurement, re-measurement is recommended. (Please rest for 4~5 mins before re-measurement) The measured values of each signal are also recorded together.
  • Page 25: Others

    Others Storage Pull the cuff plug out of Click the cuff socket. Anti-curling fastener Store the cuff. ① Place the tube into the cuff. • Please do not stretch or bend the tube with force and do not roll the tube around the main unit.
  • Page 26: Care And Maintenance

    Others Care and maintenance Cleaning frequency/maintenance cycle 1. Cleaning of main unit Visually confirm the appearance of the main unit. If there is dirt, for cleaning, please turn off the power supply and gently wipe it with cloth that is soaked in soapy water or warm water then wrung.
  • Page 27: Faq

    Others Questions Answers Why does the • Whether the cuff is properly wrapped. → Whether the cuff is too loose or too tight. systolic or → Whether the cuff is wrapped to the upper arm. diastolic blood (Refer to P18 for the correct wrapping method) pressure value •...
  • Page 28 Others Questions Answers When the hand The so-called [ ] warning means that during the measurement process, the device will give a movement or the wrist is warning when the cuff senses excess pressure due to moved, but the the movement of the arm, etc. ] mark is Therefore, the [ ] warning may not be displayed...
  • Page 29: Troubleshooting

    Others Troubleshooting Please confirm before consulting or repairing Failures Cause and solution polarities of the batteries are installed Even if the incorrectly. Please refer to P12 button is pressed, Battery power is low. Please refer to P12 there is no display The button pressing time is not sufficient.
  • Page 30 Others In case of abnormality Failures Cause and solution Low battery. Please refer to P12 Pressurization to more than 280 mmHg. Is the measurement posture correct? (P3,P17) Pressure decreased suddenly. Is the measurement method and posture correct? (P3,P17) Is the cuff wrapped correctly? (P18) Is the cuff plug inserted correctly? (P19) Please relax for 4~5 mins.
  • Page 31: Specifications

    Others Specifications Power supply 4 AA zinc carbon or alkaline batteries Display Digital LCD Method of Oscillographic system measurement Static pressure measurement range: (0.0~37.3) kPa ((0 ~ 280) mmHg) Pulse measurement range: (30~160) beats/min Measurement Blood pressure measurement range: systolic blood pressure shall range meet at least (8.0~30.7) kPa ((60 ~ 230) mmHg);...
  • Page 32 ※If stored and used outside the specified temperature and humidity range, the specified performance specifications may not be met. ※Product specifications are subject to change without further notice. Panasonic Appliances (China)Co., Ltd ©Panasonic Appliances (China)Co., Ltd Issued date: 2023.3.1 Printed in China...