2 in 1 forehead and object temperature detection (28 pages)
Summary of Contents for Welcare WET100
Page 1
OBJECT TEMPERATURE DETECTION Model: WET100 Instructions for Use & Warranty Information Read Instructions Carefully Before Use...
Page 2
Thank you for purchasing this Welcare Ear Thermometer. Model: WET100 Please keep these instructions for use in a safe place where they are readily available. Note: The illustrations in these instructions for use may differ slightly from the product itself.
Contents Important Safety Information .......... 4 Features ................ 6 Package Contents ............6 Before Using the Ear Thermometer ....... 6 Components ..............7 LCD Display ..............7 Backlit Screen .............. 8 Using the Ear Thermometer .......... 9 Setting Parameters ............9 Resetting Parameters...........
• In an emergency case, if a child swallows a battery or a probe cover, immediately consult with a doctor. • It is recommended to use this unit with a Welcare Ear Thermometer Probe Cover for hygiene purposes and accurate temperature readings.
Page 5
Important Safety Information - continued • Conducting self-diagnosis based on the measurement results and/or treatment can be dangerous. Please follow the instructions of your doctor. • If the ear is cold, wait until the ear is warmed up before taking a temperature measurement.
• Probe Cover Detection & Probe Eject Function • BPA Free Package Contents • 1 x Welcare Ear Thermometer • 1 x Packet of Probe Covers (15pc) • 1 x Instructions for Use & Warranty Information • 2 x AA Batteries...
Components A. Probe Cover (disposable) B. Probe C. Test Button D. ON/OFF Button E. Battery Cover F. SET Button G. Probe Eject Button LCD Display Date & Time Object Temperature Mode Probe Cover Symbol Unit Sign: ˚C or ˚F Temperature Indicator Temperature Mode Temperature Result Sound Symbol...
37.8˚C. Object Mode GREEN Note: The display screen will light up for 3 seconds when the unit is ready for measurement. Once the OBJECT measurement is completed, the unit will GREEN illuminate for 3 seconds. Welcare Ear Thermometer...
Using the Ear Thermometer When using the thermometer for the first time, please set the parameters of the unit as per the following instructions. • Insert the 2 x AA batteries into the unit (see p16) Note: The use of temperature readings for self-diagnosis is dangerous.
Page 10
Note: Once the date is set, the unit will turn off automatically. Note: If an Error occurs during setup, press SET repeatedly until the screen switches off and press the SET Button for 5 seconds to start again. Welcare Ear Thermometer...
Resetting Parameters Resetting the Unit of Measurement °C or °F • When the unit is turned off, press and hold the SET Button for 5 seconds. • A beep will sound and the last measurement unit ºC or ºF will appear on the screen.
“RED” Micro Switch. (see below illustration). When the probe cover is installed correctly the icon will appear on the LCD screen. To release the probe cover, gently press the Probe Eject Button. RED Micro Switch Probe Eject Button Welcare Ear Thermometer...
Taking a Measurement - continued Measuring Ear Temperature Ensure the ear canal is clean and free from earwax build-up and any obstruction before taking a measurement to ensure accurate readings. Press the button. The display is activated to show all segments on the LCD screen.
• After approximately 5 seconds, another 2 “beeps” will sound, and the Object icon will appear ready for consecutive readings. Note: This Object Mode shows the actual, unadjusted surface temperatures, which is different from the body temperature. Welcare Ear Thermometer...
Memory Function The Memory Mode can be accessed either in Ear Mode or Object Mode. When the unit has been turned on and testing complete, press, and hold the Button for three seconds. The letters MEM will appear at the bottom of the display. (left). Each time the Button is pressed, the screen displays past readings that correspond with a...
(figure C.) (figure E.) (figure D.) Replacement Accessories Replacement accessories can be purchased online or by contacting us directly: Australia: 1800 807 464 www.welcare.com.au New Zealand: 0800 523 583 www.jadavey.co.nz Part Code Part Name WET100-60 Welcare Ear Thermometer Probe Cover...
Cleaning and Maintenance If the unit is used without a probe cover, clean the probe as follows: – Use a cotton swab with the alcohol (70% concentration) to clean the lens (on the inside of the probe). • To safely clean the probe window, gently wipe its surface with a cotton swab slightly moistened with isopropyl alcohol and immediately wipe dry with a clean cotton swab.
If the message Er 5 properly. reappears, contact the retailer for service. In Object Temperature Mode, measurement is Remove probe cover in Er 6 being taken with probe object temperature mode. cover on the unit. Welcare Ear Thermometer...
Page 19
Troubleshooting - continued Error Problem Solution Code In Ear Temperature Mode: Temperature taken is higher than 43.0°C (109.4°F). Read “Measuring Ear Temperature” (page 13) In Object mode: thoroughly, then check Temperature taken the integrity of the probe is higher than 100°C cover and take a new (212°F).
The device is suitable for use Harmonic in all establishments, including emissions domestic establishments and applicable those directly connected to IEC 61000-3-2 the public low-voltage power Voltage supply network that supplies fluctuations/ buildings used for domestic flicker purposes. applicable emissions IEC 61000-3-3 Welcare Ear Thermometer...
Specifications Model Name Welcare Ear Thermometer Model Code WET100 Colour White Ear mode: 32.0°C~43.0°C (32°F~212°F) Measuring Range Object mode: 0°C~100°C (32°F~212°F) Measuring Site Ear canal (Ear Mode) Oral (This unit converts the ear Reference body site temperature to reference body site display its “oral equivalent.”)
Please register your warranty information at: AUS - www.jadavey.com.au NZ – www.jadavey.co.nz This Welcare Ear Thermometer product is warranted to be free of manufacturing defects for 1 year from the date of purchase*. This warranty is void if the product is modified or altered, is...
Page 24
3. Please return the product and warranty form at your cost to: IN AUSTRALIA J A DAVEY PTY LTD Welcare Repairs PO Box 84 Port Melbourne Victoria, Australia 3207 IN NEW ZEALAND BV Medical Welcare Repairs Unit 7, 110 Mays Road Onehunga Auckland, New Zealand 1061 Welcare Ear Thermometer...
Warranty Form PLEASE RETAIN THE WARRANTY INFORMATION. RETURN THIS PORTION ONLY WHEN YOU RETURN YOUR PRODUCT FOR REPAIR UNDER WARRANTY. NAME: ADDRESS: POSTCODE: DAYTIME PHONE: EMAIL: MODEL: DATE OF PURCHASE: PLEASE ATTACH PROOF OF PURCHASE RETAILER’S NAME: RETAILER’S ADDRESS: POSTCODE: BRIEF DESCRIPTION OF PROBLEM YOU ARE EXPERIENCING: WARRANTY IS VOID UNLESS THE ABOVE INFORMATION IS COMPLETED...
Symbol Explanation SYMBOL DESCRIPTION Indicates the need for the user to consult the instructions for use. Indicated that the caution necessary when operating the device or control close to where the symbol is placed, or that the current situation needs operator awareness or operator action to avoid undesirable consequences.
Should you require any further information please do not hesitate to contact us. Manufactured by: JOYTECH HEALTHCARE CO., LTD No.365, Wuzhou Road, Yuhang Economic Development Zone, 311100, Hangzhou, China. Manufactured for: IN AUSTRALIA: J A DAVEY PTY LTD 626 Lorimer Street Port Melbourne, VIC 3207 Telephone: 1800 807 464 Website www.jadavey.com.au...
Need help?
Do you have a question about the WET100 and is the answer not in the manual?
Questions and answers