2 in 1 forehead and object temperature detection (28 pages)
Summary of Contents for Welcare WET100
Page 1
OBJECT TEMPERATURE DETECTION SECOND READING Model: WET100 Instruction Manual & Warranty Information Read Instructions Carefully Before Use...
Page 2
Thank you for purchasing this Welcare Ear Thermometer. Model: WET100 Please keep this instruction manual in a safe place where it is readily available. Note: The illustrations in this manual may differ slightly from the product itself. Welcare Ear Thermometer...
Contents Important Safety Information .......... 4 Features ................ 6 Package Contents ............6 Before Using the Ear Thermometer ........ 6 Components ..............7 LCD Display ..............7 Backlight Screen ............8 Using the Ear Thermometer ........... 9 Switching between °C and °F ........9 Setting the Time &...
Safety Warnings • It is recommended to use this unit with a Welcare Ear Thermometer Probe Cover for hygiene purposes. • DO NOT forcibly insert the probe into the ear.
Page 5
Important Safety Information - continued • For persons wearing hearing aids or earplugs, remove the device and wait 20 minutes prior to taking a temperature. Warnings • Proper installation of the probe cover ensures accurate measurements. • If device is accidentally used without a probe cover, clean the probe as per cleaning instructions.
• Probe Cover Detection & Probe Eject Function • BPA & Latex Free Package Contents • 1 x Welcare Ear Thermometer • 1 x Packet of Probe Covers (15pc) • 1 x User Manual & Warranty Information • 2 x AA Batteries...
Components A. Probe Cover (disposable) B. Probe C. Test Button D. ON\OFF Button E. Battery Cover F. SET Button G. Probe Eject Button LCD Display Date & Time Object Temperature mode Unit sign: ˚C or ˚F Probe Cover symbol Temperature indicator Temperature mode Temperature result...
37.8˚C. Object mode Note: The display screen will light up GREEN for 3 seconds when the unit is ready for measurement. OBJECT Once the measurement is completed, the unit will GREEN illuminate for 3 seconds. Welcare Ear Thermometer...
Using the Ear Thermometer When using the thermometer for the first time, please set the parameters of the thermometer as per the following instructions. • Insert the 2 AA batteries into the unit (see p16) Note: The use of temperature readings for self-diagnosis is dangerous.
Page 10
Note: Once the date is set, the unit will turn off automatically. Note: If an Error occurs during setup, press SET repeatedly until the screen switches off and press the SET Button for 5 seconds. Welcare Ear Thermometer...
Turn Sound “ON” or “OFF” While the device is on, press the SET Button once quickly to turn the sound ON or OFF. The chosen mode icon will appear on the screen: Sound ON Sound OFF Change to Ear Mode or Object Mode Remove Probe Cover form the probe.
“RED” Micro Switch. (see below illustration). When the probe cover is installed correctly the icon will appear on the LCD screen. To release the probe cover, gently press the Probe Eject Button. RED Micro Switch Probe Eject Button Welcare Ear Thermometer...
Taking a Measurement - continued Measuring Ear Temperature Ensure the ear canal is clean and free from earwax build-up and any obstruction before taking a measurement to ensure accurate readings. Press the button. The display is activated to show all segments on the LCD screen After self-checking the icon...
• After approximately 5 seconds, another 2 “beeps” will sound, and the Object icon will appear ready for consecutive readings. Note: This object mode shows the actual, unadjusted surface temperatures, which is different from the body temperature. Welcare Ear Thermometer...
Memory Function The Memory Mode can be accessed either in Ear Mode or Object Mode. When the thermometer has been turned on and testing complete, press, and hold Button for three seconds. The letters MEM will appear at the bottom of the display.
(figure C.) (figure E.) (figure D.) Replacement Accessories Replacement accessories can be purchased online or by contacting us directly: Australia: 1800 807 464 www.welcare.com.au New Zealand: 0800 523 583 www.jadavey.co.nz Part Code Part Name WET01-60 Welcare Ear Thermometer Probes (60PK)
Cleaning and Maintenance If device is accidentally used without a probe cover, clean the probe as follows: – Use a cotton swab with the Alcohol (70% concentration) to clean the lens (on the inside of the probe). • To safely clean the probe window, gently wipe its surface with a cotton swab slightly moistened with isopropyl alcohol and immediately wipe dry with a clean cotton swab.
10°C and 40°C (50°F~104°F) Remove the batteries, wait for 1 minute The thermometer and repower it. If the is not functioning Er 5 message reappears, properly. contact the retailer for service. Welcare Ear Thermometer...
Page 19
Troubleshooting - continued Error Problem Solution Code In object temperature mode, measurement Remove probe cover is being taken with in object temperature Er 6 probe cover on the mode. device. In Ear mode: Temperature taken is higher than 43.0°C (109.4°F). In Object mode: Read Temperature Temperature taken...
Specifications Model Name Welcare Ear Thermometer Model Code WET100 Colour White Measuring Range Ear mode: 32.0°C~43.0°C (32°F~212°F) Object mode: 0°C~100°C (32°F~212°F) Measuring Site Ear canal (Ear Mode) Reference body site Oral (This thermometer converts the ear temperature to reference body site display its “oral equivalent.”)
Please register your warranty information at: AUS - www.jadavey.com.au NZ – www.jadavey.co.nz This Welcare Ear Thermometer product is warranted to be free of manufacturing defects for 1 year from the date of purchase*. This warranty is void if the product is modified...
Page 23
3. Please return the product and warranty form at your cost to: IN AUSTRALIA J A DAVEY PTY LTD Welcare Repairs PO Box 84 Port Melbourne Victoria, Australia 3207 IN NEW ZEALAND BV Medical...
Warranty Form PLEASE RETAIN THE WARRANTY INFORMATION. RETURN THIS PORTION ONLY WHEN YOU RETURN YOUR PRODUCT FOR REPAIR UNDER WARRANTY. NAME: ADDRESS: POSTCODE: DAYTIME PHONE: EMAIL: MODEL: DATE OF PURCHASE: PLEASE ATTACH PROOF OF PURCHASE RETAILER’S NAME: RETAILER’S ADDRESS: POSTCODE: BRIEF DESCRIPTION OF PROBLEM YOU ARE EXPERIENCING: WARRANTY IS VOID UNLESS THE ABOVE INFORMATION IS...
58 Richard Pearse Drive Mangere, Auckland 2022 Telephone: 0800 523 583 Website www.jadavey.co.nz Disposal At the end of its life, please treat this product as electronic waste and dispose of responsibly according to current local regulations. Made in China V12/21 Welcare Ear Thermometer...
Need help?
Do you have a question about the WET100 and is the answer not in the manual?
Questions and answers