Table 3: Unit Dimensions and Weights
System
Unit Model
BSCU-30-M1
CellarPlus 70-S1/S3
BSCU-30-M3
BSCU-35-M1
CellarPlus 80-S1/S3
BSCU-35-M3
BSCU-30-M1
CellarPlus 70-T1/T3
BSCU-30-M3
BSCU-35-M1
CellarPlus 80-T1/T3
BSCU-35-M3
BSCU-40-M1
CellarPlus 90-T1/T3
BSCU-40-M3
Table 4: Electrical Data and Requirements
System
Unit Model
BSCU-30-M1
CellarPlus 70-S1/S3
BSCU-30-M3
BSCU-35-M1
CellarPlus 80-S1/S3
BSCU-35-M3
BSCU-30-M1
CellarPlus 70-T1/T3
BSCU-30-M3
BSCU-35-M1
CellarPlus 80-T1/T3
BSCU-35-M3
BSCU-40-M1
CellarPlus 90-T1/T3
BSCU-40-M3
Notes:
(1) RRC: Rated Run Current (RRC) and power consumption of outdoor unit, rated at 10°C DB / 8°C WB and 32°C ambient.
(2) MCC: Maximum Continuous Current; LRA: Locked Rotor Amps. Both values are for the unit compressor only.
(3) SFR: Suggested Fuse Rating (Motor Rated for Outdoor Unit)
Table 5: Outdoor Unit Sound Spectrums
Model
BSCU-30-M1/M3
BSCU-35-M1/M3
BSCU-40-M1/M3

Health and Safety

Only a qualified refrigeration engineer, who
is familiar with refrigeration systems and
components including all controls, should
perform the installation and start-up of the
system. To avoid potential injury, use care
when working around coil surfaces or sharp edges of
metal cabinets. All piping and electrical wiring should be
installed in accordance with all applicable codes,
ordinances, and local by-laws.
Issue: 01.06.2023
Outdoor Units
W x D x H
Fixing Ctrs.
(mm)
(mm)
1108 x 478 x 649
703 x 448
1334 x 530 x 864
946 x 500
1108 x 478 x 649
703 x 448
1334 x 530 x 864
946 x 500
1351 x 530 x 864
946 x 500
Outdoor Units
Power Supply
Power
(V/ph/Hz)
(kW)
230/1/50
2.70
400/3/50
230/1/50
3.08
400/3/50
230/1/50
2.90
400/3/50
230/1/50
3.17
400/3/50
230/1/50
3.65
400/3/50
1/1 Octave Sound Pressure Levels
@ 1 meter from front of the unit
125 Hz
250 Hz
500 Hz
62.1
56.7
51.3
63.5
62.7
53.1
61.4
61.7
58.6
Weight
Unit Model
(kgs)
77
1x JCC2-80EV
76
97
1x JCC2-80EV
96
77
2x JCC2-40EV 865 x 505 x 489
76
97
2x JCC2-50EV 904 x 504 x 546
96
107
2x JCC2-60EV 904 x 504 x 546
107
SFR
(2)
(2)
(1)
MCC
LRA
RRC
(3)
(A)
(A)
(A)
(A)
21.5
82.0
12.2
25
10.3
40.0
5.1
16
25.0
97.0
14.0
32
9.0
46.0
5.7
20
21.5
82.0
13.3
25
10.3
40.0
5.4
16
25.0
97.0
14.3
32
9.0
46.0
5.8
20
28.0
114.0
17.4
40
11.0
50.0
6.8
20
Frequency
1 kHz
2 kHz
48.2
43.1
48.6
43.9
55.2
51.7

General Information

Before Installation
Ensure the units received are the correct models for the
intended application.
Ensure the refrigerant, voltage and maximum working
pressure are all suitable for the proposed application.
Check there is no damage to the units. Any damage
should be reported to the supplier immediately.
Check that the proposed equipment locations are
suitable and provide adequate support for the weight
of the units.
Offloading and Lifting
Indoor Units
W x D x H
Fixing Ctrs.
(mm)
Top (mm)
1437 x 505 x 557 1173 x 324 1173 x 310
1437 x 505 x 557 1173 x 324
745 x 122
826 x 122
826 x 122
Indoor Units
Power Supply
Unit Model
(V/ph/Hz)
1x JCC2-80EV
230/1/50
1x JCC2-80EV
230/1/50
2x JCC2-40EV
230/1/50
2x JCC2-50EV
230/1/50
2x JCC2-60EV
230/1/50
4 kHz
8 kHz
A (dBA)
38.3
31.3
54.1
38.8
32.4
56.3
48.3
43.1
60.7
Fixing Ctrs.
Weight
Rear (mm)
(kgs)
63
1173 x 310
63
(2x)
745
33
(2x)
826
36
(2x)
826
38
Power
(1)
(3)
RRC
SFR
(kW)
(A)
(A)
0.43
1.9
6
0.43
1.9
6
0.45
2.0
6
0.44
2.0
6
0.44
2.0
6
Noise Levels
(10m)
A (dBA)
34
36
41
Page 3

Advertisement

Table of Contents
loading

Related Products for J&M CellarPlus 70-S1/S3

Table of Contents