Table 14: Controller Parameters
Label
Hy
Differential
ot
Probe calibration
AC
Anti Short Cycle Delay
CH
Kind of Action (Cool / Heat)
rE
Resolution (°C only): dE = decimal between -9.9 ~ 9.9°C; in = integer
id
Interval between defrost cycles
Md
Maximum defrost length
AU
Maximum Air Alarm Temperature (Not Applicable)
AL
Minimum Air Alarm Temperature (Not Applicable)
iP
Digital input polarity: oP = activated by closing the contact; cL = activated by opening the contact
Digital input configuration: EA = external alarm; EA message is displayed: bA = serious alarm; CA
iF
message is displayed: do = door switch function: dF = defrost activation: Au = not used: Hc = inversion of
the kind of action
Digital input delay. With iF = EL or bA delay between the detection of the external alarm condition and its
di
signalling. With iF = do it represents the delay to activate the door open alarm
LS
Minimum Set Point
US
Maximum Set Point
od
Output activation delay at startup
Cy
Compressor on time faulty probe. Cy = 0 compressor always OFF
Cn
Compressor off time faulty probe. Cn = 0 compressor always active
CF
Measurement units: °C = Celsius; °F = Fahrenheit
dY
Display delay
Display during defrost: rt = real temperature; it = start defrost temperature: St = SET POINT: dF = label
dF
dF
Ad
Temperature alarm delay
dA
Exclusion of temperature alarm at startup
Compressor and fan status when door open: no = normal; Fn = Fans OFF; cP = Compressor OFF; Fc =
dC
Compressor and fans OFF
Regulation with door open: n = no regulation if door is opened; Y = when di is elapsed regulation restarts
rd
even if door open alarm is present
Pt
Parameter code table
rL
Firmware release
Issue: 01.06.2023
Dixell XR02CX Parameters
Description
Parameter Menu (selected parameters)
Hidden Parameter Menu (Full list including above parameters)
Range
Default setting JEH Setting
0.1 ~ 25°C / 1 ~ 45°F
2.0°C / 4°F
-9.9 ~ 9.9°C / -18 ~ 18°F
0.0
0 ~ 50 minutes
cL ~ Ht
dE ~ in
dE
0 ~ 99 hours
0 ~ 99 minutes
20
~ 99°C / ~210°F
99°C / 99°F
-55°C / -67°F
-55°C / -55°F
cL ~ oP
EA / bA / do / dF / Au / db
EA
/ Hc
0 ~ 99 minutes
-55°C / -67°F
-55°C / -55°F
99°C / 210°F
99°C / 99°F
0 ~ 99 minutes
0 ~ 99 minutes
15
0 ~ 99 minutes
30
°C / °F
°C
0 ~ 15 minutes
rt / it / St / dF
0 ~ 99 minutes
15
0 ~ 99 minutes
90
no / Fn / cP / Fc
no
n ~ Y
Read Only
Read Only
2.0°C
0.0
1
3
cL
cL
in
8
6
30
99°C
-55°C
cL
cL
EA
5
5
4°C
16°C
0
0
5
10
°C
0
0
it
it
15
90
no
Y
Y
-
-
-
-