Download Print this page

Kingray MD100VS Installation Manual

A2 stereo/double sideband modulators

Advertisement

Quick Links

STANDARD COMMUNICATIONS CONTRACT WARRANTY AGAINST DEFECTS
This warranty against defects is given by Standard
this warranty (to the extent permitted at law), we
Communications Pty Ltd ACN 000 346 814 (We, us,
agree to supply those services again at no extra
our or GME). Our contact details are set out in clause
charge to you.
2.7. This warranty statement only applies to products
2.6 To make a warranty claim you must before
purchased in Australia. Please contact your local GME
the end of the applicable warranty period (see
distributor for products sold outside of Australia. Local
warranty table), at your own cost, return the
distributor details at www.gme.net.au/export.
goods you allege are defective, provide written
details of the defect, and give us an original or
1. Consumer guarantees
copy of the sales invoice or some other evidence
1.1 Our goods come with guarantees that cannot be
showing details of the transaction.
excluded under the Australian Consumer Law.
2.7 Send your claim to:
You are entitled to a replacement or refund for
Standard Communications Pty Ltd.
a major failure and for compensation for any
PO Box 96, Winston Hills, NSW 2153.
other reasonably foreseeable loss or damage.
Tel: (02) 8867 6000, Fax: (02) 8867 6199
You are also entitled to have the goods repaired
Email: servadmin@gme.net.au
or replaced if the goods fail to be of acceptable
2.8 If we determine that your goods are defective, we
quality and the failure does not amount to a
will pay for the cost of returning the repaired or
major failure.
replaced goods to you, and reimburse you for your
1.2 To the extent we are able, we exclude all other
reasonable expenses of sending your warranty
conditions, warranties and obligations which
claim to us.
would otherwise be implied.
3. What this warranty does not cover
2. Warranty against defects
3.1 This warranty will not apply in relation to:
2.1 This warranty is in addition to and does not
(a) goods modified or altered in any way;
limit, exclude or restrict your rights under the
(b) defects and damage caused by use with non
Competition and Consumer Act 2010 (Australia)
Standard Communications products;
or any other mandatory protection laws that may
(c) repairs performed other than by our authorised
apply.
representative;
2.2 We warrant our goods to be free from defects
(d) defects or damage resulting from misuse,
in materials and workmanship for the warranty
accident, impact or neglect;
period (see warranty table) from the date of
original sale (or another period we agree to in
(e) goods improperly installed or used in a manner
writing). Subject to our obligations under clause
contrary to the relevant instruction manual; or
1.2, we will at our option, either repair or replace
(f) goods where the serial number has been
goods which we are satisfied are defective. We
removed or made illegible.
warrant any replacement parts for the remainder
4. Warranty period
of the period of warranty for the goods into which
they are incorporated.
4.1 We provide the following warranty on GME and
2.3 To the extent permitted by law, our sole liability
Kingray products. No repair or replacement during
for breach of a condition, warranty or other
the warranty period will renew or extend the
obligation implied by law is limited
warranty period past the period from original date
(a) in the case of goods we supply, to any one of
of purchase.
the following as we decide -
(i) the replacement of the goods or the supply of
Product Type
equivalent goods;
(ii) the repair of the goods;
Kingray amplifiers, modulators,
(iii) the cost of repairing the goods or of acquiring
diplexers and filters, Kingray plug
equivalent goods;
pack power supplies, Kingray Pro-
(b) in the case of services we supply, to any one of
fessional rack mount products.
the following as we decide –
(i) the supplying of the services again;
(ii) the cost of having the services supplied again.
2.4 For repairs outside the warranty period, we
warrant our repairs to be free from defects in
materials and workmanship for three months from
the date of the original repair. We agree to re-
repair or replace (at our option) any materials or
workmanship which we are satisfied are defective.
2.5 We warrant that we will perform services with
reasonable care and skill and agree to investigate
any complaint regarding our services made in
good faith. If we are satisfied that the complaint
is justified, and as our sole liability to you under
Warranty
Period
3 years
A division of Standard Communications Pty Ltd.
Head Office: PO Box 96, Winston Hills, NSW 2153, Australia.
New Zealand: PO Box 58446 Botany, Auckland, 2163,
NZ. T: (09) 274 0955.
All international enquiries email: export@gme.net.au
Drawing No: 41773-9 Part No: 310194
INSTALLATION MANUAL
Specialists in TV signal amplification
MD100VS (44-470 MHz)
MD100US (470-860 MHz)
A2 STEREO/DOUBLE SIDEBAND MODULATORS
Optimised for both digital and analogue TV
The MD100VS/US are double sideband Phase
signal amplification.
Locked Loop (PLL) Stereo Modulators. They
feature input AV level adjustments, high output
Thank you for selecting an Australian designed
with gain control, internal test pattern function
and built F Type masthead amplifier.
and Mono Option (see left).
MD100VS
MD100US
The MD100VS/US are intended for indoor use.
The modulator/s may be rack mounted via
the KR001 or on a flat surface with screws
provided. An earth lug has been included if
required.
CABLE CONNECTIONS
All input connections (video, left and right
audio) are RCA. The RF Output is an 'F' Type
Connector.
POWERING OPTIONS
The supply voltage (12-18 V DC) is supplied
by the separately purchased PSK18S or
the PSK18KR for rack mounted or multiple
powered units. (ADC322 or ADC325 power
splitter cables may be used if 2 or more units
are to be installed without the rack).The
products may also be line powered
if required via a PIK01.
ADJUSTMENTS
01. Video Input
08. 20 dB Gain Control
1. Output Frequency Selection
02. Left Audio
09. 20 dB Attenuation
Double sideband output requires ONE full
Channel Input
Switch
7 MHz channel spacing below the selected
03. Right Audio
10. Stereo or
Channel Input
Mono Switch
frequency to be left vacant.
04. Video Level
11. Test Pattern Switch
e.g. Ch. 40
Adjustment
12. SW3
Ch. 41
05. Left Channel Audio
13. SW2
Ch. 42
Level Adjustment
14. SW1
Ch. 43
06. Right Channel Audio
15. Power LED
Level Adjustment
Select frequency required from supplied
16. DC Jack
07. Non Adjustable
information on reverse side. Adjust Dip
Factory Preset
17. RF Output
Switches per example shown on the reverse
side.
INSTALLATION
610-617 MHz - Vacant
617-624 MHz - Selected
624-631 MHz - Vacant
631-638 MHz - Selected

Advertisement

loading
Need help?

Need help?

Do you have a question about the MD100VS and is the answer not in the manual?

Questions and answers

Summary of Contents for Kingray MD100VS

  • Page 1 3.1 This warranty will not apply in relation to: 2.1 This warranty is in addition to and does not The MD100VS/US are intended for indoor use. (a) goods modified or altered in any way; limit, exclude or restrict your rights under the...
  • Page 2 Adjustment required if audio levels set at the same output level to eliminate intermodulation effects. SPECIFICATIONS PARAMETER SPECIFICATION MD100VS (44 - 470 MHz) Frequency Range MD100US (470 - 860 MHz) RF Performance Output Level 63-103 dBµV Adjustable Output Impedance 75 ‘F’...

This manual is also suitable for:

Md100us