Velleman DVM4200 User Manual page 16

6600 counts multi function multimeter
Hide thumbs Also See for DVM4200:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
9.7. Diode and audible continuity test
Range
Built-in buzzer sounds if resistance < 30Ω
Forward test current(DC): ± 1mA
Reversed test voltage: ± 2.8Vdc
9.8. Capacitance
Range
Resolution
6.6nF
66nF
660nF
6.6µF
66µF
660µF
6.6mF
66mF
9.9. Temperature
Range
-55°C ~ 0°C
1°C ~ 400°C
401°C ~ 1,000°C
Note: thermocouple errors not included
9.10. Frequency
Range
Resolution
66.66Hz
0.01Hz
660.0Hz
6.600KHz
66.00kHz
660.0kHz
6.600MHz
66.00MHz
Use this device with original accessories only. Velleman nv cannot be held
responsible in the event of damage or injury resulted from (incorrect) use
of this device. For more info concerning this product and the latest version
of this user manual, please visit our website www.velleman.eu. The
information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
This manual is copyrighted. The copyright to this manual is owned by Velleman nv. All
worldwide rights reserved. No part of this manual may be copied, reproduced, translated or reduced
to any electronic medium or otherwise without the prior written consent of the copyright holder.
24.06.2015
1pF
10pF
100pF
1nF
10nF
100nF
1µF
10µF
Resolution
0.1°C
1°C
(1Hz~1MHz)
0.1Hz
1Hz
10Hz
±(0.1% of rdg + 3 digits)
100Hz
1KHz
10KHz
DVM4200
parameters
Accuracy
(5.0% of rdg + 5 digits)
(3.0% of rdg + 3 digits)
(5.0% of rdg + 3 digits)
Accuracy
Logic
16
-
Accuracy
±(5.0% of rdg + 4°C)
±(2.0% of rdg + 3°C)
±(2.0% of rdg)
Linear
(6Hz~10KHz)
±(0.05% of rdg + 8 digits)
N.A.
©Velleman nv

Advertisement

Table of Contents
loading

Table of Contents