Service Procedure - Onkyo TX-SR606 Service Manual

Hide thumbs Also See for TX-SR606:
Table of Contents

Advertisement

SERVICE PROCEDURE-1

1. Replacing the fuses
This symbol located near the fuse indicates that the
fuse used is show operating type, For continued protection against
fire hazard, replace with same type fuse, For fuse rating, refer to
the marking adjacent to the symbol.
Ce symbole indique que le fusible utilise est e lent.
Pour une protection permanente, n'utiliser que des fusibles de meme
type. Ce demier est indique la qu le present symbol est apposre.
REF NO.
PART NAME
F901
FUSE
F901 or
FUSE
F901
FUSE
F901 or
FUSE
F901
FUSE
F901 or
FUSE
F901
FUSE
F901 or
FUSE
F902
FUSE
F902 or
FUSE
F910
FUSE
F910 or
FUSE
F6901
FUSE
F6902
FUSE
<Notes>
<MDD> : USA model
<MDC> : Canadian model
<MPP> : European model
<MPA> : Australian model
<MPB> : British model
2. Safety check out
(U.S.A. model only)
After correcting the original service problem, perform the following safety check before releasing the unit to the customer.
Leakage current Check
Measure the leakage current to a known earth ground (water pipe or conduct etc.) by connecting a leakage current
tester between the earth ground and exposed metal parts of the unit (input/output ground terminals, screw heads or metal overlays etc.).
Plug the power supply cord directly into a 120Vac 60Hz wall socket and turn ON/STANDBY button on.
Any current measured must not exceed 0.5mA.
3. Memory Backup
This model uses a EE-PROM IC in order to retain radio presets and other settings. So, memory contents will be
kept eternally with no care.
4. To initialize the unit
1. Press and hold down VCR/DVR button, then press ON/STANDBY button when the unit is powered on.
2. After " Cl ea r " is displayed, the preset memory and each mode stored in the memory, are initialized and
will return to the factory settings.
DESCRIPTION
PART NO.
10A-UL/T-233
252330GR
10A-T/UL-ST2
252333GR
5A-SE-EAK
252078GR
5A-SE-TL250V
252278GR
5A-SE-EAK
252078GR
5A-SE-TL250V
252278GR
5A-SE-EAK
252078GR
5A-SE-TL250V
252278GR
5A-SE-EAK
252078GR
5A-SE-TL250V
252278GR
5A-UL/T-233
252326GR
5A-T/UL-ST2
252258GR
12A-TUL-250V
252301GR
12A-TUL-250V
252301GR
<MGK> : Korean model
<MGQ> : Hong kong model
<MGR> : Chinese model
REMARKS
!, <MDD, MDC>
!, <MDD, MDC>
!, <MGK, MGQ, MGR>
!, <MGK, MGQ, MGR>
!, <MPP, MPA, MPB>
!, <MPP, MPA, MPB>
!, <MWT, MWO, MWF>
!, <MWT, MWO, MWF>
!, <MWT, MWO, MWF>
!, <MWT, MWO, MWF>
!
!
!
!
<MGK> : Korean model
<MGQ> : Hong kong model
<MGR> : Chinese model
TX-SR606

Advertisement

Table of Contents
loading

Table of Contents