CONDTROL SMART 60 - Laser Distance Meter Manual

CONDTROL SMART 60 - Laser Distance Meter Manual

Advertisement

CONDTROL SMART 60 - Laser Distance Meter Manual

FUNCTIONS/APPLICATIONS

Laser distance meter SMART 60 is intended to measure distance, lengths, heights, calculate area and volume of measured objects as well as to carry out indirect measurements (Pythagoras' Theorem). The product is suitable for use at both indoor and outdoor building areas.

SET

  1. Laser distance meter – 1pc.
  2. Carry pouch with a strap - 1 pc.
  3. User manual – 1 pc.
  4. Batteries LR3 (AAA) – 2 pcs.

SPECIFICATIONS

Working range 0,05 – 60 m*
Measuring accuracy ± 1,5 mm**
Smallest unit displayed 1 mm
Automatic shutdown Laser Instrument Display backlight 45 sec 180 sec √
Continuous distance measuring (Tracking)
Addition/Subtraction of measurements
Area/volume calculation
Indirect measurement (Pythagoras' Theorem)
Laser type 650 nm, < 1 mW, class II
Working temperature 0 °С... +40 °С
Storage temperature –20 °С... +60 °С
Battery 105х47х27 mm
Dimensions 83 г
Weight 2х1,5 V AAA LR3 (alkaline)

* Use a target plate to increase the measurement range during daylight or if the target has poor reflection properties.

** Accuracy can decrease in unfavorable conditions, such as intense sunshine or when measurements are made against glossy or transparent surfaces, moving objects, objects with rough surface.

In unfavourable conditions or when measured distance is over 100 m the maximum permissible accuracy is calculated in the following way:
± (Y + 0,25хDх10-3) mm, where

D (mm) - measured distance
Y (mm) - permissible accuracy according to technical data.

INSERT/REPLACE BATTERIES

INSERT/REPLACE BATTERIES
Insert the batteries, observing correct polarity. Use alkaline batteries only, both batteries must be of the same brand with the same charge level. Charge level is shown on display. Replace batteries when you see symbol on the display.

SWITCH ON/OFF

To switch on the product press . The product will switch on and enter measuring mode.

To switch of the product press and hold .
In order to save battery power the product will switch off automatically within 3 minutes after the last operation.

PRODUCT DESCRIPTION

PRODUCT DESCRIPTION

  1. Bubble level
  2. Display
  3. Switch on / activate laser beam/ measurement / continuous measurement (tracking).
  4. Addition/subtraction / switch on/off sound signal.
  5. Area/volume calculation/indirect measurement (Pythagoras' Theorem).
  6. Switch off/clear
  7. Strap location

Display

Display Overview

  1. Secondary line for displaying measuring results, maximal and minimal values.
  2. Symbol of Addition/ subtraction mode
  3. Symbol indicating area and volume calculation, indirect measurement mode. 4 Main line for displaying measuring results
  4. Battery charge level
  5. Reference point
  6. Unit of measurement

OPERATION

Reference point

It is possible to set the reference point - from the top or bottom end of the product.

The default reference point is the bottom end of the product. To select reference point press and hold button during 1 second. Indicator will appear on the display.

Switch on/off sound signal

To switch on/off sound signal press and hold during 2 seconds.

MEASUREMENTS

Single distance measurement

Switch on the product. Short press to switch on laser beam, point it at the target and press again for single distance measurement.

Short press to switch off laser beam, if it is on.
Single distance measurement

Continuous distance measurement (Tracking)


Press and hold . The product will take measurements one after another, showing the last measured value. Besides it will show maximal and minimal measured values.

To exit the mode press or .

CALCULATIONS

The last measurement can be cancelled by and made again in modes of area and volume calculation, indirect measurement mode (Pythagoras' Theorem). If you double press in any of the above mentioned modes, the product will enter single distance measuring mode.

Addition/Subtraction

Addition/Subtraction function is used for addition and subtraction of lengths.

Addition/Subtraction
Make a single distance measurement, activate Addition/ Subtraction mode by short pressing , then make the next single distance measurement. Calculation result will be shown in the main line on the display. The next measurements will also be added/subtracted to/from the next measuring result.

Press to exit
Addition/Subtraction mode.

Area

Area
Press . Symbol will appear on display. Make 2 measurements one by one (length and width). Area (composition of length and width) will be calculated and shown in the main line on the display.

Volume


Press twice. Symbol will appear on display. Make 3 measurements one by one (length, width, height). Volume (composition of length, width and height) will be calculated and shown in the main line on the display.

Volume

Indirect measurement (Pythagorean Theorem)

Indirect measurement (Pythagorean Theorem) - Part 1
If it is impossible to make direct measurement (there is some obstruction) required length can be calculated with the help of 2 others.

Press 3 times. Symbol will appear on display. Measure length of segments A and B. Segment B must be perpendicular to segment C and can't be longer than segment A. Lenght of segment C is calculated according to Pythagoras' Theorem.

Indirect measurement (Pythagorean Theorem) - Part 2

MESSAGE CODES

While operation, the following codes/symbols may appear on the display:

Message Cause Solution
301 Distance is out of range Keep in correct measuring range
302 Reflected signal is too weak Use reflecting plate
303 Measuring result cannot be displayed (negative or exceeds 99999) Repeat measurements
304 Pythagorean theorem calculation error Make measurements in correct succession
305 Low battery Replace batteries
306 Temperature is too low Warm up the product
307 Temperature is too high Cool down the product
308 Ambient light is too strong Make measurements in less illuminated zone

CONDTROL GmbH
Wasserburger Strasse 9
84427 Sankt Wolfgang
Germany

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download CONDTROL SMART 60 - Laser Distance Meter Manual

Advertisement

Need help?

Need help?

Do you have a question about the SMART 60 and is the answer not in the manual?

Questions and answers

Table of Contents