ECT Install and User Guide 0 of 61 ECOER INC. ECT01 Wi-Fi Programmable Thermostat Install and User Guide 1. Safety precaution -------------------------------------------- 2. Installation accessory --------------------------------------- 3. Installation method ----------------------------------------- 4. Specification --------------------------------------------------- 5. Feature and function of the wired controller ---------- 6.
Page 2
ECT Install and User Guide 1 of 61 ECOER INC. This manual gives detailed description of the precautions that should be brought to your attention during operation. In order to ensure correct service of the wired controller please read this manual carefully before using the unit.
ECT Install and User Guide 2 of 61 ECOER INC. 1. Safety Precaution WARNING • Please entrust the distributor or professionals to install the unit. • Installation by other persons may lead to imperfect installation, electric shock or fire. • Adhere to this installation manual.
ECT Install and User Guide 3 of 61 ECOER INC. NOTE • The specified cables shall be applied in the wiring. No external force may be applied to the terminal. Otherwise, wire cut and heating may occur and result in fire.
Page 5
ECT Install and User Guide 4 of 61 ECOER INC. 2. 2 Prepare the following assemblies on the site. Qty.(embeded Specification Remarks Name into wall) (only for reference) Switch box Wiring Tube(Insulating Sleeve and Tightening Screw) Precaution of installing the wire controller 1.
ECT Install and User Guide 5 of 61 ECOER INC. 3. Installation method 3.1 Wired remote controller structural dimensions 20.6mm 120mm 46mm Fig 3-1 60mm 3.2 Remove the upper part of wired controller • Insert a slot screwdriver into the...
Page 7
ECT Install and User Guide 6 of 61 ECOER INC. NOTE : The PCB is mounted in the upper part of the wired controller. Be careful not to damage the board with the slot screwdriver. 3.3 Fasten the back plate of the wired •...
Page 8
ECT Install and User Guide 7 of 61 ECOER INC. NOTE : Put on a flat surface. Be careful not to distort the back plate of the wire controller by overtightening the mounting screws. 3.4 Battery installation Fig 3-5 • Put the battery into the installationsite and make sure the positive side of the battery is in accordance with the positive side of installationsite.
Page 9
ECT Install and User Guide 8 of 61 ECOER INC. 3.5 Wire with the indoor unit 60mm Wiring hole HA HB Fig 3-6 Indoor unit Notch the part for the wiring to pass through with nippers, etc. Connect the terminals on the wired controller (HA ,HB), and the terminals of the indoor unit (HA ,HB).
Page 10
ECT Install and User Guide 9 of 61 ECOER INC. For some units, the wired controller connects to the unit HA and HB ports through the HA and HB ports. There is no polarity between HA and HB. See Fig. 3-7...
Page 11
ECT Install and User Guide 10 of 61 ECOER INC. For some units, one wired controller can support multiple units (a maximum of 16 units). In this case, the wired controller and unit need to be connected to the HA and HB ports at the same time. In group control, there will be no error displayed on the wired controller .
Page 12
ECOER INC. 3.6 Warranty Registration via ESS Pro App With the wired controller, Ecoer Inc. provides an easy way for dealers to help their customers complete registration via Ecoer Smart Service (ESS) Pro App in just minutes. Then dealers can monitor units’...
Page 13
ECT Install and User Guide 12 of 61 ECOER INC. Steps of warranty registration * 1. Create an ecoer account 2. Add Unit (Register a new Wired Controller/AC/HP) • Sign an agreement with homeowner • Scan/Input serial numbers to submit *Log in ESS Pro App >Files >Installation to get the newest guide.
ECT Install and User Guide 13 of 61 ECOER INC. 4. Specification Input voltage Ambient temperature 0~43℃(32~110℉) Ambient humidity RH40%~RH90% Wiring specifications NOTE: Suggested to use the connective wire of 6 meters length. Manufacturer reserves the right to change specifications or designs without notice.
ECT Install and User Guide 14 of 61 ECOER INC. 5. Feature and function of the wired controller Feature: • LCD display. • Malfunction code display: it can display the error code, helpful for service. • 4-way wire layout design, no raised part at backside, more convenient to place the wires and install the device.
ECT Install and User Guide 15 of 61 ECOER INC. 6. Name on the LCD of the wired controller °C / °F display MODE display Temperature display Room temperature display Displays the current mode,including: Relative humidity display Lock display Wireless control feature...
ECT Install and User Guide 16 of 61 ECOER INC. Name of button on the wired controller 1. FAN SPEED button 7. COPY button 2. MODE button 8. POWER button 3. FUNC. button 9. CONFIRM button 4. SWING button 10. BACK botton 5.
ECT Install and User Guide 17 of 61 ECOER INC. 8. Preparatory operation Set the current day and time Press the Timer button for 2 seconds or more. The timer display will flash. Press the button “ ” or “...
ECT Install and User Guide 18 of 61 ECOER INC. Time scale selection Press the buttons “ ” and “ ” for 2 seconds will alternate the clock time display between the 12h & 24h scale. Operation To start/stop operation Press the Power button.
Page 20
ECT Install and User Guide 19 of 61 ECOER INC. To set the operation mode Operation mode setting(Heat mode is invalid for cool only type unit) Press this button to select the operation mode: If the indoor unit has Electric heating(Emergent...
Page 21
ECT Install and User Guide 20 of 61 ECOER INC. Room temperature setting Press the button“ ”or “ ” to set the room Lower temperature. Indoor Setting Temperature Range : 10/16/17~30°C(50/60/62~86°F ) or 20~28°C(68~82°F ). Raise (Model dependent) °C & °F scale selection (on some models) Press the buttons “...
Page 22
ECT Install and User Guide 21 of 61 ECOER INC. Child lock function Press the buttons “ ” and “ ” for 3 seconds to activate the child lock function and lock all buttons on the wire controller. You can't press the button to operate and receive the remote control signal after the child lock is activate.
Page 23
ECT Install and User Guide 22 of 61 ECOER INC. Swing function(For the units without vertical swing function ) • Use Swing button to adjust the Up-down airflow direction and start the auto swing function. 1. Each time you press this button, the louver swings an angle of 6 degrees.
Page 24
ECT Install and User Guide 23 of 61 ECOER INC. 3. And then use Swing button to adjust the Up-Down airflow direction of the selected louver. Press the FUNC. button to scroll through operation functions as followings: [*]: Model dependent. If the indoor unit has no this function, it will not display.
Page 25
ECT Install and User Guide 24 of 61 ECOER INC. Intelligent eye display 1. This function is valid in any mode of power-on state. 2. When the indoor unit sending wire controller has the smart eye function, press the function key to select the smart eye icon, press the OK key to turn on the smart eye, and light up the smart eye icon at the same time;...
Page 26
ECT Install and User Guide 25 of 61 ECOER INC. Humidity setting function 1. When the indoor unit sending wire controller has dual control function of temperature and humidity, in dehumidification mode, press the function key to select the RH icon, press the confirm key to...
Page 27
ECT Install and User Guide 26 of 61 ECOER INC. GEAR function 1.When the indoor unit sending wire controller has the GEAR function, in the boot cooling mode, press the function key to select the GEAR icon, press the confirm key to enter the GEAR control mode, and first display the current GEAR status.
Page 28
ECT Install and User Guide ECOER INC. 27 of 61 Rotation & Back-up indication When there are two units, press the button to select the rotating function, and press “Confirm” to turn on or off the rotating function. 1. Press “Confirm” to set the rotating time, then press the button “...
ECT Install and User Guide 28 of 61 ECOER INC. 10. Timer functions WEEKLY timer Use this timer function to set operating times for each day of the week. On timer Use this timer function to start air conditioner operation.
Page 30
ECT Install and User Guide 29 of 61 ECOER INC. To set the On or Off TIMER Press the Timer button to select the No display Press the Confirm button and the Timer display is flashing. ex. Off timer set at 18:00 Press the button “...
Page 31
ECT Install and User Guide 30 of 61 ECOER INC. To set the On and Off TIMER Press the Timer button to select the Press the Confirm button and the Clock display is flashing. Press the button“ ”or “ ” to set the time of On timer, and then press the Confirm button to confirm the setting.
ECT Install and User Guide 31 of 61 ECOER INC. 11. Weekly Timer 1 1 Weekly timer setting Press the Timer button to select the then press the Confirm button to confirm. 2 Day of the week setting Press the button “...
Page 33
ECT Install and User Guide 32 of 61 ECOER INC. ex.Tuesday time scale 1 Up to 4 timer settings can be saved for each day of the week. It is conventent if the WEEKLY TIMER is set according to the user’s life style.
Page 34
ECT Install and User Guide 33 of 61 ECOER INC. WEEKLY timer operation To activate WEEKLY TIMER operation Press the Timer button while is displayed on the LCD. To deactivate WEEKLY TIMER operation Press the Timer button while is disappear from the LCD.
Page 35
ECT Install and User Guide 34 of 61 ECOER INC. To set the DAY OFF (for a holiday) During the weekly timer, press the Confirm button. Press the button“ ” or“ ”to select the day in this week . Press the Day off button to set the DAY OFF.
Page 36
ECT Install and User Guide 35 of 61 ECOER INC. DELAY function During the weekly timer, press the FUNC. button , select the delay function and press the Confirm button, display“ " “ "" " and wait 3 seconds to confirm. When the delay function is activated, the “...
Page 37
ECT Install and User Guide 36 of 61 ECOER INC. Press the Copy button, the letter “CY” will be shown on the LCD. Press the button“ ” or “ ” to select the day to copy to. Press the Copy button to confirm .
ECT Install and User Guide 37 of 61 ECOER INC. 12. Weekly Timer 2 1 Weekly timer setting Press Timer to select the and press Confirm. 2 Day of the week setting Press “ ” or “ ” to select the day of the week and then press CONFIRM.
Page 39
ECT Install and User Guide 38 of 61 ECOER INC. IMPORTANT: Up to 8 scheduled events can be set on one day. Various events can be scheduled in either MODE, TEMPERATURE and FAN speeds. ex.Tuesday time scale 1 4 Time setting Press “...
Page 40
ECT Install and User Guide 39 of 61 ECOER INC. 7 Fan speed setting Press “ ”or “ ” to set the speed then press CONFIRM. NOTE : This setting is unavailable in the AUTO, DRY or OFF modes. 8 Different scheduled events can be set by repeating steps 3 through 7.
Page 41
ECT Install and User Guide 40 of 61 ECOER INC. WEEKLY timer operation Press Timer to select the , and then the To start timer starts automatically. To cancel Press the Power buttons for 2 seconds to cancel the timer mode.
Page 42
ECT Install and User Guide 41 of 61 ECOER INC. Press DAY OFF to create an off day. mark is hidden ex.The DAYOFF is set for Wednesday Set the DAY OFF for other days by repeating the steps 2 and 3.
Page 43
ECT Install and User Guide 42 of 61 ECOER INC. Press “ ” or “ ” to select the day to copy from. Press COPY, the letters CY appear on the LCD. Press “ ” or “ ” to select the day to copy to.
Page 44
ECT Install and User Guide 43 of 61 ECOER INC. Delete the time scale in one day. During the weekly timer setting, press CONFIRM. Press“ ” or“ ”to select the day of the week and then press CONFIRM. Press “ ” or “...
ECT Install and User Guide 44 of 61 ECOER INC. 13.Fault alarm handing If the system does not properly operate except the above mentioned cases or the above mentioned malfunctions is evident, investigate the system according to the following procedures.
ECT Install and User Guide 45 of 61 ECOER INC. 15.Queries and settings When the air conditioning unit is switch machine, Long press “COPY” for 3 seconds , first display P:00, if connected to an indoor unit, display P:00, if connected to multiple indoor units, press “...
Page 47
ECT Install and User Guide 46 of 61 ECOER INC. Follow me function temperature compensation When the air conditioning unit is off, into the query function of temperature, press“ ”or “ ”to select tF. The compensation temperature Range : -5~5°C.
Page 48
ECT Install and User Guide 47 of 61 ECOER INC. Set the highest and lowest temperature values When the air conditioning unit is off, into the query function of temperature, press“ ”or“ ”to select tHI or tLo. Press “Confirm” into setting state, press“...
Page 49
ECT Install and User Guide 48 of 61 ECOER INC. Two - line controller address selection When the air conditioning unit is off, into the query function of temperature, press“ ”or “ ”to select Adr, the temperature zone will display -- or A, B. Where -- refers to the code setting of the wire controller.
Page 50
ECT Install and User Guide 49 of 61 ECOER INC. After the wire controller resumes the factory parameter setting, the rotating parameter setting is restored to 10 hours (the highest and lowest temperature are not set); The compensation of body temperature is uncompensated;...
ECT Install and User Guide 50 of 61 ECOER INC. 16.Wireless control connection SAFETY PRECAUTION Read the safety precautions carefully before installing the unit. Stated below are important safety issues that must be obeyed. Applicable system: IOS, Android. (Suggest: IOS 9.0 and above, Android 6.0 and above.)
Page 52
ECT Install and User Guide 51 of 61 ECOER INC. CAUTION • Please Check The Service Website For More Information. • Smart Phone camera needs to be 5 million pixels or above to make sure scan QR code well. • Due to different network situation, sometimes, request time-out could happen, thus, it is necessary to do network configuration again.
Page 53
ECOER INC. DOWNLOAD AND INSTALL APP On an app market (Google Play Store, Apple App Store), search for "Ecoer Home Plus" and find the Ecoer Home Plus app. Download and install it on your phone. Fig.16 -1 • Please ensure your mobile device is connected to Wireless Network router.
Page 54
53 of 61 ECOER INC. Network configuration by Ecoer Home Plus App *The design of Ecoer Home Plus App may subject to change. You can download the the newest guide by scanning the QR code below. Fig.16 - 2 Manufacturer reserves the right to change specifications or designs without notice.
Page 55
ECT Install and User Guide 54 of 61 ECOER INC. 2 Choose device type 1 Press “ + Add Device ” Fig.16 - 3 Fig.16 - 4 Manufacturer reserves the right to change specifications or designs without notice. Feb 2023...
Page 56
ECT Install and User Guide 55 of 61 ECOER INC. 4 Connect to Device Wi-Fi 3 Select home Wi-Fi, enter the password Fig.16 - 5 Fig.16 - 6 Manufacturer reserves the right to change specifications or designs without notice. Feb 2023...
Page 57
ECT Install and User Guide 56 of 61 ECOER INC. 5 Wait connecting to the network 6 Configuration Success Fig.16 - 8 Fig.16 - 7 Manufacturer reserves the right to change specifications or designs without notice. Feb 2023...
Page 58
ECT Install and User Guide 57 of 61 ECOER INC. 7 You can bind rooms to device 8 The network configuration is successful, now you can see the device in the list Fig.16 - 9 Fig.16 - 10 Manufacturer reserves the right to change specifications or designs without notice.
Page 59
ECT Install and User Guide 58 of 61 ECOER INC. NOTE • Make sure your devices are powered on. • Keep your mobile phone close enough to your device when you are connecting network to your device. • Connect your mobile phone to the wireless network at home, and make sure you know the password of the Wireless Network.
Page 60
ECT Install and User Guide 59 of 61 ECOER INC. APP DECLARATION Hereby, we declare that this Smart kit is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. A copy of the full DoC is attached.(European Union...
Page 61
ECT Install and User Guide 60 of 61 ECOER INC. NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.