SPIN TROUBLE
While spinning, is the frequency of the
water level 248 or more. The frequency can be
checked by pressing the [Spin] and [Temp.] buttons at
the same time on the program.
Press [Power] button with [Temp] and [Option]
buttons pressed after power off. Press [Start/Pause]
button 2 times. Does the drum rotate at low spin
speed?
Is it disconnected or badly contacted?
Check the motor connector, Is the resistance between
the terminal in figure the same as below?
Resistance between terminals
¥L ~ ¥P: 0.5 ~ 1.0Ω
¥P ~ ¤ : 1.5 ~ 2.5Ω
Be sure to unplug the machine before measuring.
MOTOR TERMINAL
1 2 3 4 5 6 7 8 9 10
Replace the PWB assembly.
YES
NO
NO
YES
23
Check the sensor
(Pressure) or hose
(Sensor).
NO
If the problem is on the
sensor or the hose, replace
the sensor or the hose.
YES
Normal
YES
Reconnect or repair it.
NO
Replace the motor
assembly.