Z-Wave Smoke Sensor PSG01
The Z-Wave Smoke Sensor PSG01 is designed to give early warning of
developing fires by giving off the alarm sounds from its build-in alarm
horn, based on Z-Wave
TM
technology.
It is the Z-Wave
TM
plus product, it support the security, OTA... Those
newest features of the Z-Wave
communication protocol designed for home automation, specifically to
remotely control applications in residential and light commercial
environments. The technology uses a low-power RF radio embedded or
retrofitted into home electronics devices and systems, such as lighting,
home access control, entertainment systems and household appliances.
This product can be included and operated in any Z-Wave
with other Z-Wave
TM
certified devices from other manufacturers and/or
other applications. All non-battery operated nodes within the network
will act as repeaters regardless of vendor to increase reliability of the
network.
The device adopt the Z-Wave
network system is all made by Z-Wave
network system will have the advantages as below.
Concurrent multi-channel support reduces external interference.
TM
technology. Z-Wave
TM
TM
500 series chip, when your Z-Wave
TM
500 series devices. The
Better RF range, improve about 10 meters in indoor.
Support 100 Kbps transmit speed, speed up communication.
Add to/Remove from Z-Wave
There is one button on the device. It can be used to add, remove, reset
from Z-Wave
In the first time, add the device into the Z-Wave
make sure the primary controller is in the add mode. And then insert
battery to power on the device. Press the button once to start the NWI
(Network Wide Inclusion) mode. And it should be added in 5 seconds.
Notice: Including a node ID allocated by Z-Wave
"Add" or "Inclusion". Excluding a node ID allocated by Z-Wave
is a wireless
Controller means "Remove" or "Exclusion".
Function
Add
TM
network
Remove
TM
Reset
1
TM
TM
network.
Description
1. Have Z-Wave
TM
Controller entered inclusion mode.
2. Pressing button three times within 1.5 seconds to
enter the inclusion mode.
3. After add successful, the device will wake to
receive the setting command from Z-Wave
Controller about 20 seconds.
1. Have Z-Wave
TM
Controller entered exclusion mode.
2. Pressing button three times within 1.5 seconds to
enter the exclusion mode.
Node ID has been removed.
Notice: Use this procedure only in the event
that the primary controller is lost or
otherwise inoperable.
1. Pressing button four times within 1.5 seconds and
do not release the button in the 4
Network
TM
network. First,
TM
Controller means
TM
TM
th
pressed, and

Advertisement

loading

Summary of Contents for Z-Wave PSG01

  • Page 1 Press the button once to start the NWI (Network Wide Inclusion) mode. And it should be added in 5 seconds. The Z-Wave Smoke Sensor PSG01 is designed to give early warning of developing fires by giving off the alarm sounds from its build-in alarm horn, based on Z-Wave technology.
  • Page 2 Failed or success in add/remove the node ID can be viewed • from Z-Wave Controller. Notification Report (V4) Notification Type: Smoke (0x01) Notice 1: Always Remove a Z-Wave device before trying to add it to Event: Smoke detected, Unknown Location (0x02) a Z-Wave network Smoke Alarm Test (0x03)
  • Page 3: Power Up Procedure

    This is the only way to make sure that the Smoke Sensor device is working properly. If the device fails to test properly, have it repaired or The device support the Z-Wave firmware update via OTA. replaced immediately. If you suspect that your Smoke Sensor does not...
  • Page 4: Battery Installation

    Choosing a Suitable Location go into alarm, test it by pressing the test button to ensure if it works properly. For complete coverage in residential units, Smoke Sensors should be Notice : To keep the Smoke Sensor in good working condition, installed in all rooms, halls, storage areas, basements and attics in each testing the device weekly is necessary.
  • Page 5: Installation

    Z-Wave Supported Command Class If a 20-foot distance is not possible, e.g. in a mobile home, try to install the alarm as far away from the combustion particles as possible, preferably on the wall. To prevent nuisance alarm alarms, provide good COMMAND_CLASS_ZWAVEPLUS_INFO_V2 ventilation in such places.
  • Page 6: Specifications

    908.40 MHz, 916.00 MHz(US), Name Description Def. Valid 922~927 MHz(JP/TW), 921.40 MHz, 919.80 MHz(ANZ), Customer function switch, using bit 869.00 MHz(RU), control. 865.20 MHz(IN), 916.00 MHz(IL), Bit0: Reserve. Bit1: Reserve. Range: Bit2: Reserve. Minimum 40 meters indoor, 100 meters outdoor line of sight. Customer Bit3: Reserve.
  • Page 7: Fcc Interference Statement

    FCC Interference Statement Warning This equipment has been tested and found to comply with the limits for Do not dispose of electrical appliances as unsorted municipal waste, a Class B digital device, pursuant to Part 15 of the FCC Rules. These use separate collection facilities.