Installation/Care/Use Manual
Soft Sides
ERO28C
Installer
To assure you install this model easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK
YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND
OTHER APPLICABLE CODES. After installation, leave these instructions inside the
fountain for future reference.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK
INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN
INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER
SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING
PLUMBING SYSTEM.
3/8" O.D. UNPLATED COP-
1/4" O.D. TUBE
PER TUBE CONNECT
WATER INLET
COLD WATER SUPPLY
TO COOLER
NOTE: WATER FLOW
DIRECTION
FIG. 1
ERO2-8C*C, 2C
Refrigerated Fountains with FLEXI-GUARD
™
13
SEE FIG. 7
39
14
39
IMPORTANT
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
EROA2-8RAC*A
ERO28RAC
OPERATION OF QUICK CONNECT FITTINGS
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE TO ATTACH
A
B
A
B
FIG. 2
Page 1
®
TUBE IS SECURED
PUSH IN COLLET
TUBE IS SECURED
PUSH IN COLLET
IN POSITION
IN POSITION
TO RELEASE TUBE
TO RELEASE TUBE
C
C
PUSHING TUBE IN BEFORE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
PULLING IT OUT HELPS TO
RELEASE TUBE
RELEASE TUBE