Download Print this page

U-Line U-29RW-00A User Manual & Service Manual page 34

Hide thumbs Also See for U-29RW-00A:

Advertisement

USER GUIDE
USER GUIDE
Compressor Specifications
DANGER
!
Electrocution can cause death or serious injury.
Burns from hot or cold surfaces can cause
serious injury. Take precautions when servicing
this unit.
Disconnect the power source.
Do not stand in standing water when working
around electrical appliances.
Make sure the surfaces you touch are not hot or
frozen.
CHECK TERMINAL PINS
To measure the start winding resistance, measure across
the C and S pins.
To measure the run winding resistance, measure across
the C and R pins.
Also check S to R and you should get the sum of the run
and start windings.
To ensure the windings are not shorted, check the S and
R to ground.
Compressor Specifications
Compressor Specifications
OVERLOAD PROTECTOR
STARTING RELAY
RELAY COVER
Refrigerant
Voltage
Frequency
Run Cap
Start Winding
Run Winding
LRA
FLA
Starting Device
Overload
* All resistance readings are ±10%
34
u-line.com
C
S
R
CAPACITOR
EMX20CLC
R600a
115 - 127 VAC
60 Hz
12μF/165 VAC
6.7 Ohm at 77°F
12.6 Ohm at 77°F
3.7 A
0.5 A
8EA14C