Gree GWH18YD-K6DNA2A Service Manual page 79

Table of Contents

Advertisement

Steps
6. Remove the soundproof sponge
Tear off the sticking stripe and then remove the
soundproof sponge.
7. Remove isolation plate
Remove the 2 screws connecting the isolation plate
and condenser side plate; remove the 3 screws
connecting the isolation plate and chassis, and then
remove the isolation plate.
8. Remove
4-way valve assy
Unsolder the welding joints connecting the 4-way
valve assy with capillary sub-assy, compressor and
condenser; remove the 4-way valve.
Note:
Before unsoldering the welding joint, wrap the 4-way
valve with a wet cloth completely to avoid damage to
the valve caused by high temperature.
76
Procedure
Isolation sheet
Service Manual
soundproof sponge
4-way valve assy