5.
MAINTENANCE
WARNING! Disconnect wrench from air supply before changing accessories, servicing or
performing maintenance. Replace or repair damaged parts.
Use genuine parts only.
Unauthorised parts may be dangerous and will invalidate the warranty.
5.1.
If the air system does not have an oiler, lubricate the air wrench daily with a few drops of
Sealey air tool oil dripped into the air inlet.
5.2.
Clean the wrench after use. DO NOT use worn, or damaged sockets.
5.3.
Loss of power or erratic action may be due to the following:
a) Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or
type of hose connectors. To remedy, check the air supply and follow instructions in Section 3.
b) Grit or gum deposits in the wrench may also reduce performance. Remove the strainer,
clean it and flush the wrench out with gum solvent oil or an equal mixture of SAE No:10
oil and paraffin. Allow to dry before use.
5.4.
For a full service contact your local Sealey service agent.
5.5.
When not in use, disconnect from air supply, clean wrench and store in a safe, dry,
childproof location.
Impact Wrench, Model No. SA684 when operated in accordance with these instructions and tested in
accordance with EN 28662-2: 1994 results in the following vibration emission declared in accordance with
BS EN12096: 1996.
Measured vibration emission value: . . . . . . . . . . . . . 5.9m/s
Uncertainty: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.36m/s
These values are suitable for comparison with emission levels of other tools that have been subject to
the same test.
This tool may cause hand-arm vibration syndrome if its use is inadequately managed.
Recommended Measures to reduce risk of hand-arm vibration syndrome:
This tool should not be used by an individual regularly for more than 2.9 hours in any 8 hour period.
This duration of use should be reduced if the individual is exposed to hand-arm vibration from other sources.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
Risk of Hand Arm Vibration Injury
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
²
²
01284 757500
01284 703534
www.sealey.co.uk
Web
sales@sealey.co.uk
email
SA684 Issue: 3 - 12/12/11

Advertisement

loading