Load Cell Replacement - Cardinal CenterPoint DB-SP Technical Manual

Load cell kits
Table of Contents

Advertisement

The following procedure describes changing the load cell in a DB-SP CenterPoint, mild steel
powder painted, or stainless steel low-profile load cell stand.
5
8
DANGER!
WITH BLOCKS OR OTHER SUPPORTS TO ENSURE THE STABILITY OF THE
VESSEL, BEFORE LIFTING IT OFF THE LOAD CELL STAND.
1. To start, turn off or unplug the indicator and then disconnect the load cell from the junction
box. Refer to the JUNCTION BOX WIRING section of this manual for wiring information.
2. Next, using a jack at the load cell to be replaced, lift the vessel to remove the load off the
load cell stand, and high enough to place blocks or other supports under the vessel to
ensure its stability while replacing the load cell.
NOTE: If the vessel is empty, a chain or cable slings can be used to lift the vessel
to remove the load off the load cell stand, and high enough to place blocks or other
supports under the vessel to ensure its stability while replacing the load cell.

LOAD CELL REPLACEMENT

2
7
TO PREVENT TIPPING OF THE VESSEL, SUPPORT THE VESSEL
3500-0418-0M Rev A • DB-SP Load Cell Kits
4
1
6
2
3
4
11

Advertisement

Table of Contents
loading