The purpose of adjusting trim is so the same weight reading will be displayed regardless of where
the load is placed on the scale deck. All scales are corner trimmed before leaving the factory. In
the event of re-calibration or load cell replacement, follow the instructions below to re-trim the
corners. It is assumed the other three load cells are already corner-sealed to agree with each
other. If not, please refer to the next page for further instructions.

Single Load Cell

1. Remove the junction box cover access plate located on the side of the scale.
2. Remove the junction box access cover.
3. Refer to the figure below for load cell location reference.
4. Turn the trim potentiometer for the load cell needing re-calibration clockwise for 25 turns, or
until a click is heard indicating the end of the potentiometer adjustment.
5. Place a test weight on each corner, one at a time, and record the displayed weight for each
corner.
6. Place a test weight on the corner with the highest reading and adjust the appropriate trim
potentiometer until the weight reading agrees with the lowest reading obtained in Step 5.
7. Repeat Step 6 until all corners have the same weight reading.
8. Replace the screws securing the junction box cover and access plate.
12

TRIM ADJUSTMENT

Cell locations are
for reference only!
Trim Box
1913-0609-0M Rev A • SLS Series Owner's