Royal Sovereign ARP-906EC Owner's Manual

Royal Sovereign ARP-906EC Owner's Manual

Royal sovereign arp-906ec: user guide
Table of Contents

Advertisement

Available languages

Available languages

OWNER'S MANUAL
MANUAL DEL PROPIETARIO
ARP-906EC
Portable Air Conditioner
Acondicionador de Aire Portátil
Read and retain these instructions for future reference
For any Customer Support needs, please choose
the Support tab on www.royalsovereign.com
Royal Centurian Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ARP-906EC and is the answer not in the manual?

Questions and answers

Summary of Contents for Royal Sovereign ARP-906EC

  • Page 1 OWNER’S MANUAL MANUAL DEL PROPIETARIO ARP-906EC Portable Air Conditioner Acondicionador de Aire Portátil Read and retain these instructions for future reference For any Customer Support needs, please choose the Support tab on www.royalsovereign.com Royal Centurian Inc.
  • Page 2: Table Of Contents

    - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Model ARP-906EC...
  • Page 3: Parts

    PARTS Handle Rear Casters Front Casters w/ Lock Exhaust Air Hose Control panel Air Outlet Air Louvers Exhaust Air Outlet Power Cord Drain Port ARP-906EC Evaporator Filter Condenser...
  • Page 4: Before Use

    BEFORE USE SAFETY PRECAUTIONS If unit has been transported on its side set the machine upright for 2 hrs. before use. 1. Only use in the upright position on a flat, level surface at least 20”/50cm from any object or water leak may occur. 2.
  • Page 5: Installation

    ARP-906EC INSTALLATION 1. Connect the hose to the exhaust air outlet. 2. Insert the exhaust hose into the window spacer. NOTE: The hose may be extended from 1-5 ft/300-1500mm but for maximum efficiency use the shortest length possible. For best results do not let the exhaust hose exceed a 45° angle.
  • Page 6: Operation/Functions

    OPERATION/FUNCTIONS CONTROL PANEL 1. Temperature/Hour LED Display 2. Power button 3. Power/Water Full indicator light 4. Temperature DOWN button 5. Temperature UP button 6. Mode button (Fan, Cool, Auto, Dry) 7. Fan indicator light 8. Cool indicator light 9. Auto indicator light 10.
  • Page 7 (1-12) you want the unit turned off in. Example- If you want the unit to turn off after 4 hours then press the button until it shows 4, the unit will automatically turn off in 4 hours. ARP-906EC...
  • Page 8 SLEEP By pressing the SLEEP button, the set temperature will increase 2°F / 1°C in the first hour, another 2°F / 1°C in the second hour and then remains at that temperature. WATER FULL When the water tank is full the POWER/WATER FULL light will light up and you will hear a beeping noise. At this point you must empty it out by placing a container underneath the drain port, remove the rubber drain plug and then water will flow out until it is empty.
  • Page 9: Maintenance

    ARP-906EC MAINTENANCE Always unplug the air conditioner from the outlet before cleaning. To maximize the efficiency of the air conditioner, clean regularly. Cleaning the Filter Remove the filter from the side of housing. Use a vacuum cleaner or gently tap the filter to remove loose dust and dirt, then rinse thoroughly under warm running water.
  • Page 10: Troubleshooting

    • If possible, place back in its original carton or cover for storage. • Always keep the unit in the upright position TROUBLESHOOTING Problem The air conditioner does not run The machine is not cooling very well The unit is vibrating Sudden noise NOTE: Never try to repair or dismantle the unit yourself.
  • Page 11: Specifications

    Power/Ampere Air volume Noise level Moisture removal Thermostat Refrigerant Timer Recommended room size Unit weight Unit dimensions ARP-906EC 9000 BTU’s 120V/60Hz 1050 W / 9.5A 400M3 / Hr 54 dB(A) 30L/day 64.4-89.6°F / 18-32°C 1-12 hours 300 sq. ft 70.6 (lbs) 32 (kg) 31.5 x 15.0 x 24.9 (in) 800 x 382 x 635 (mm)
  • Page 12: Warranty

    Royal Sovereign service center, of any defective part(s) thereof, other than parts damaged in transit. This warranty is in effect to the original purchaser, for a period of one year from the date of purchase and is not transferable. This warranty shall apply only if the air conditioner is used on Alternating Current (AC) circuit, in accordance with the factory provided instructions which accompany it.
  • Page 13: Manual Del Propietario

    Spanish OWNER’S MANUAL MANUAL DEL PROPIETARIO ARP-906EC Acondicionador de Aire Portátil Lea y conserve estas instrucciones para referencia futura Para preguntas, por favor. Visite nuestra página de internet www.royalsovereign.com servicio al cliente. Royal Centurian Inc.
  • Page 14 ACONDICIONADOR DE AIRE PORTÁTIL Modelo ARP-906EC ÍNDICE GENERAL Componentes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -...
  • Page 15 ARP-906EC COMPONENTES Panel de control Manilla Salida de aire Rejillas desviadoras del aire Filtro de evaporación Ruedas orientables posteriores Salida de aire de extracción Condensador Ruedas orientables con traba Cable de alimentación Orificio de drenaje Manguera para extracción de aire...
  • Page 16: Antes Del Uso

    ANTES DEL USO PRECAUCIONES DE SEGURIDAD Si la unidad ha sido transportada de lado coloque la máquina en posición vertical por 2 horas antes de usar. 1. Use la unidad sólo en su posición vertical sobre una superficie plana y nivelada, a una distancia mínima de 20 pulg./50 cm de cualquier objeto o podría ocurrir un escape de agua.
  • Page 17: Instalación

    ARP-906EC INSTALACIÓN 1. Conecte la manguera a la salida de extracción de aire 2. Inserte la manguera de escape en el separador de la ventana. NOTA: La manguera se puede extender de 1 a 5 pies/300 a 1500 mm, pero, para obtener el máximo rendimiento, use la menor longitud posible.
  • Page 18 OPERACIÓN/FUNCIONES PANEL DE CONTROL 1. Pantalla de LED para temperatura/hora 2. Botón de encendido 3. Luz indicadora Power/Water Full 4. Botón DOWN para la temperatura 5. Botón UP para la temperatura 6. Botón Mode (Fan, Cool, Auto, Dry) 7. Luz indicadora Fan 8.
  • Page 19 (1 a 12) que desea que transcurran antes de que se apague la unidad. Por ejemplo, si desea que la unidad se apague dentro de 4 horas, presione el botón hasta que aparezca 4, y la unidad se apagará automáticamente dentro de esa cantidad de horas. ARP-906EC...
  • Page 20 SLEEP Al presionar el botón SLEEP (DESCANSO), la temperatura de referencia aumentará 2° F / 1° C en la primera hora y otros 2° F / 1° C en la segunda, y luego mantendrá esa temperatura. WATER FULL Cuando el tanque se encuentre lleno, la luz POWER/WATER FULL (ENCENDIDO/LLENO DE AGUA) se encenderá y se escuchará...
  • Page 21: Mantenimiento

    ARP-906EC MANTENIMIENTO Siempre desenchufe el acondicionador de aire del tomacorriente antes de limpiarlo. Para obtener el máximo rendimiento del acondicionador de aire, límpielo con frecuencia. Limpieza del filtro Quite el filtro del costado de la carcasa. Limpie el filtro con una aspiradora o dele golpes suaves a fin de eliminar el polvo y suciedad sueltos;...
  • Page 22: Solución De Problemas

    Limpieza de la carcasa Use un paño suave y húmedo para limpiar el cuerpo de la unidad. No use nunca productos químicos, gasolina, detergentes, paños químicamente tratados ni ninguna clase de solución de limpieza, ya que es posible que se dañe la carcasa. Almacenamiento •...
  • Page 23: Especificaciones

    Eliminación de humedad Termostato Refrigerante Temporizador Tamaño recomendado de la habitación Peso de la unidad Dimensiones de la unidad ARP-906EC 9000 BTU 120 V/60 Hz 1050 W / 9.5 A 400 m 54 dB(A) 30 L/día 64.4 a 89.6° F/18 a 32º C...
  • Page 24 Royal Sovereign. Esta garantía está en vigencia para el comprador original por un período de un año, a partir de la fecha de compra, y es intransferible. Esta garantía sólo se aplicará...